Driveline screen: drop turbine tile, show output shaft as provisional rpm

Turbine speed removed from the display - it's an engagement diagnostic, not a
driver number, and the Launch now gives output speed directly so it's no
longer needed for the ratio-calibration method either. Still decoded in the
driver. Its screen slot now shows accelerator pedal %.

Output shaft now displays approximate rpm instead of raw counts, via a
PROVISIONAL factor from the single Launch reference (128 rpm / 1192 raw =
~0.107, through a known zero). The tile is labelled "OUTPUT (~rpm)" - the "~"
keeps an unlocked scaling from reading as exact. Replace the factor once a
multi-point Launch sweep gives a real fit.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
This commit is contained in:
2026-07-17 18:15:42 +02:00
parent e10e03eb90
commit 037227ba34
3 changed files with 27 additions and 10 deletions
+12
View File
@@ -192,6 +192,18 @@ typedef struct __attribute__((packed)) {
#define CAN_BYTE_OUTPUT_SHAFT_L 3
#define CAN_BYTE_OUTPUT_SHAFT_H 4
// PROVISIONAL output-shaft factor, from a SINGLE Launch reference reading
// (128 rpm at raw 1192, 2026-07-17) taken through a known zero. Good enough to
// put an approximate rpm on the display (±~10%), NOT good enough to trust for
// anything computed. Replace once a multi-point Launch sweep gives a real fit.
// rpm ~= raw * 1074 / 10000
#define OUTPUT_SHAFT_RPM_NUM 1074
#define OUTPUT_SHAFT_RPM_DEN 10000
static inline uint16_t can_output_shaft_rpm(uint16_t raw) {
return (uint16_t)(((uint32_t)raw * OUTPUT_SHAFT_RPM_NUM) / OUTPUT_SHAFT_RPM_DEN);
}
// --- 0x1A2 turbine speed (EGS, DLC 4, 20 ms) -------------------------------
// Gearbox INPUT speed. Physically proves engagement: free-spins at ~engine
// speed in P/N, collapses to ~0 when the box engages against a held output.