Rename Controller A/B -> Main CTRL / Inst. Cluster (user); Sleep when the car is off: Settings switch, deep sleep on quiet CAN + idle screen, CAN RX wake, switch mirrored to the cluster; docs
Firmware / build (push) Successful in 7m22s
Firmware / build (push) Successful in 7m22s
This commit is contained in:
@@ -6,7 +6,7 @@ updated: 2026-09-23
|
||||
|
||||
# Route A probe — first live run (2026-09-23)
|
||||
|
||||
First execution of the [[obd-diagnostic-polling]] Route A test: the `diag` console probe on Controller A, engine idling, Launch unplugged, tapped PT-CAN. Two sessions, raw console logs (CANRAW + CANTX + diag output interleaved):
|
||||
First execution of the [[obd-diagnostic-polling]] Route A test: the `diag` console probe on Main CTRL, engine idling, Launch unplugged, tapped PT-CAN. Two sessions, raw console logs (CANRAW + CANTX + diag output interleaved):
|
||||
|
||||
- `raw/diag-20260923-111737.log` — `pids`, `pid 0C`, `pid 05`, `pid 0B`, `pid 70`, `vin`, `ecu`, `status`
|
||||
- `raw/diag-20260923-111851.log` — `pid 10`, `pid 04`, `pid 0F`, `pid 0D`, `pid 1C`, `pid 01`, `pid 21`, `status`
|
||||
|
||||
@@ -20,7 +20,7 @@ raw: raw/ESP32-S3-Touch-LCD-5-details-intro.jpg
|
||||
|
||||
## Relevance
|
||||
|
||||
- Confirms the terminal-block signal set and that the RS485 pair is the only UART1 exit → `(sibling: 1.3 wiki → controller-link)` open question #1 on how the wire to Controller B is really made
|
||||
- Confirms the terminal-block signal set and that the RS485 pair is the only UART1 exit → `(sibling: 1.3 wiki → controller-link)` open question #1 on how the wire to Inst. Cluster is really made
|
||||
- Confirms one shared termination switch for CAN and RS485 — keep it **OFF** when tapping the vehicle CAN bus, which also leaves the RS485 link unterminated on this end
|
||||
- Strapping pads IO0/IO3/IO4/IO46 exist as solder points — the only bare GPIO access on the board, and all four are already committed (G3, VSYNC, CTP_IRQ, HSYNC)
|
||||
|
||||
|
||||
@@ -19,7 +19,7 @@ Raw: `raw/ESP32-S3-Touch-LCD-5-Sch.pdf` (3 sheets, V1.2), re-downloaded 2026-09-
|
||||
## 5 V rail budget (for whatever hangs on VOUT)
|
||||
|
||||
- `VIN` (7–36 V terminal) → `D17` 1N5822 reverse-protection Schottky + `D3` SMAJ36CA TVS → `U1` **SY8293** synchronous buck → **`DC_5V`**, `L3` 4.7 µH 8 A, note *"Run the line at current 2A"*. `DC_5V` feeds the 5 V rail (and VBUS via `Q4` AO3401 ideal-diode-style switch).
|
||||
- Sheet note: *"The screen itself consumes close to 550 mA"*; the wiki's whole-board figure is ~450 mA @ 5 V. Realistic headroom on VOUT@5 V from the 12 V input: **roughly 1 A**, comfortably enough for Controller B (~150–200 mA) `(unverified estimate; the regulator is rated for 2 A total)`.
|
||||
- Sheet note: *"The screen itself consumes close to 550 mA"*; the wiki's whole-board figure is ~450 mA @ 5 V. Realistic headroom on VOUT@5 V from the 12 V input: **roughly 1 A**, comfortably enough for Inst. Cluster (~150–200 mA) `(unverified estimate; the regulator is rated for 2 A total)`.
|
||||
- On USB-only power the 5 V rail is the host's 500 mA — do not load VOUT then.
|
||||
- Caveat for the vehicle: the 36 V TVS is the only transient clamp; the ISO 7637 concern in [[open-questions]] #6 stands.
|
||||
|
||||
|
||||
@@ -23,7 +23,7 @@ Official product documentation for the ESP32-S3-Touch-LCD-5 family. Covers four
|
||||
- **120 Ω termination resistor switch, OFF by default** — correct setting for tapping into an existing, already-terminated vehicle bus; leave it off.
|
||||
|
||||
**Other onboard peripherals:**
|
||||
- RS485 via SP3485, automatic TX/RX direction switching (this is the terminal block the firmware uses for UART1 → Controller B `(repo)`).
|
||||
- RS485 via SP3485, automatic TX/RX direction switching (this is the terminal block the firmware uses for UART1 → Inst. Cluster `(repo)`).
|
||||
- Optocoupler-isolated digital I/O: inputs 5–36 V (dry/wet contact, NPN or PNP), open-drain outputs sinking up to 450 mA/channel.
|
||||
- PCF85063 RTC with CR927 coin-cell holder.
|
||||
- TF card slot (SD_CS must be driven via CH422G EXIO4).
|
||||
|
||||
@@ -6,7 +6,7 @@ updated: 2026-09-23
|
||||
|
||||
# Launch live-data capture — rail pressure decoded (2026-09-23)
|
||||
|
||||
The capture-with-Launch session that [[obd-diagnostic-polling]] had been pointing at since July, finally run. Engine idling, our read-only logger (`tools/serial_logger.py`) on Controller A's USB recording the full `CANRAW` stream while the Launch polled the DDE; then the user selected **Rail Pressure (actual)** and blipped to 2500 rpm for a second calibration point. Raw: `raw/serial-COM10-20260923-163511.log` (~13 MB, both halves of every exchange).
|
||||
The capture-with-Launch session that [[obd-diagnostic-polling]] had been pointing at since July, finally run. Engine idling, our read-only logger (`tools/serial_logger.py`) on Main CTRL's USB recording the full `CANRAW` stream while the Launch polled the DDE; then the user selected **Rail Pressure (actual)** and blipped to 2500 rpm for a second calibration point. Raw: `raw/serial-COM10-20260923-163511.log` (~13 MB, both halves of every exchange).
|
||||
|
||||
## Headline: rail pressure actual is decoded and VERIFIED
|
||||
|
||||
@@ -41,7 +41,7 @@ This is the key operational finding: **rail pressure is served in the DDE's defa
|
||||
- **The method generalises**: any value the Launch will display can be decoded the same way — capture the `2C`/`6C` pair while its screen shows the number, calibrate scale against the display at two points. Boost, MAF, injection quantity, EGTs are each one session away. See [[obd-diagnostic-polling]] "Beyond the probe".
|
||||
- **Self-poll is feasible without any secret.** To read rail pressure ourselves: send the one-time define `2C 10 15 E0`, then poll `2C 10 00 DF` → parse `6C 10 HHLL`. **No `10` session, no `27` security, no `3E` tester-present required** (proven above). The only barriers are our own choices, not the ECU's — see the two below.
|
||||
- **It is still a transmit-on-the-bus action, and `2C` is not strictly read-only** (it writes a definition into the ECU's dynamic-identifier table — harmless, but a state change). So it stays outside the current probe whitelist by policy.
|
||||
- **Intended home (design decision, 2026-09-23):** any active polling belongs behind a **password-protected "Diagnostics" screen** on Controller A — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records [[open-questions]]; not built yet.
|
||||
- **Intended home (design decision, 2026-09-23):** any active polling belongs behind a **password-protected "Diagnostics" screen** on Main CTRL — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records [[open-questions]]; not built yet.
|
||||
- No EGS traffic (`0x618`) — only the DDE (`0x612`) answered; the Launch was on an engine page.
|
||||
|
||||
## Related
|
||||
|
||||
Reference in New Issue
Block a user