Engine data screen: live rail, boost, charge-air temp, battery from the DDE
New screen (Engine data button on Driveline) polls the DDE with the Launch's KWP `2C 10 <id>` reads: 00DF rail (bar = raw x 0.03, verified), 0091 boost (mbar = raw / 8), 16A8 charge-air temp, 0093 battery - the last three provisional (one engine-off point each), tagged on screen with the raw value shown for calibration. DiagProbe live mode: `2C 10 15 E0` once, then the four reads in turn, one in flight, ~100 ms apart, quiet on the console, paused by the foreign-tester guard, stops 1.5 s after the screen stops asking. 2C stays forbidden from the console. CANDriver::transmit gains an echo flag (live frames echoed only with CANRAW on). Wiki: the three CANNY captures ingested, identifier table and the no-password decision recorded. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -147,12 +147,13 @@ namespace CANDriver {
|
||||
/**
|
||||
* Transmit ONE standard (11-bit) frame, single-shot (no automatic
|
||||
* retransmission if nobody ACKs). The only write path onto the vehicle
|
||||
* bus; reserved for DiagProbe's on-demand diagnostic requests. Echoes the
|
||||
* frame on the console as a "CANTX," line (same shape as CANRAW) so
|
||||
* captures hold both halves of an exchange.
|
||||
* bus; reserved for DiagProbe (console requests + the Engine data screen's
|
||||
* live poll). Echoes the frame on the console as a "CANTX," line (same
|
||||
* shape as CANRAW) so captures hold both halves of an exchange; the live
|
||||
* poll passes echo=false unless CANRAW logging is on (10 frames/s).
|
||||
* @return true if the frame was queued (delivery is reported via stats)
|
||||
*/
|
||||
bool transmit(uint32_t id, const uint8_t* data, uint8_t len);
|
||||
bool transmit(uint32_t id, const uint8_t* data, uint8_t len, bool echo = true);
|
||||
|
||||
/**
|
||||
* Enable/disable raw frame logging (candump-style capture of EVERY frame).
|
||||
|
||||
Reference in New Issue
Block a user