Clarify self-poll needs no session/security; record Diagnostics-screen plan

- capture proof: Launch used only 1A/2C/22/23 - no 10/27/3E. Self-polling a
  2C live value needs just the define + poll, no session or security seed.
  Corrected the earlier "needs session handshake" wording.
- design decision: active polling (if built) lives behind a password-
  protected Diagnostics screen - authorized-tech gate, manual, refuses with
  a scan tool connected, read-oriented services. open-questions #12.
- wiki: launch-capture + obd-diagnostic-polling tightened; project memory
  added so the capability and guard rails are not re-researched later

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
2026-09-23 17:06:20 +02:00
parent 6bdf4d43a9
commit da4c96903b
4 changed files with 23 additions and 5 deletions
+4 -2
View File
@@ -66,7 +66,7 @@ The [[dwr-335d-torque-pids]] source is a worked, gauge-checked set of J1979 mode
First live exchange without any scan tool: `diag bmw 12 1A 86` → 65-byte multi-frame ident from `0x612`, containing DDE part numbers (7 799 764 / 7 799 765 / 7 793 887), a 2006-03 date, and the **VIN prefix `WBANC92090` → E60 530d** `(verified bytes / unverified decode)` — full breakdown in [[diag-route-b-2026-09-23]]. `22 F1 90` (UDS) is rejected: the DDE speaks **KWP2000, not UDS** — pointing at DDE6/EDC16. `1A 90` (full VIN) answers busyRepeatRequest to a single-shot probe. **Same day, identifier scans**: the clipping's `22 D1xx` identifiers are confirmed wrong (whole block NRCs), and a `21 xx` sweep shows the measurement blocks are **gated behind a diagnostic session / security access** (NRC 0x22/0x33) — outside the probe's read-only whitelist by design.
**Capture-with-Launch done, and it worked — [[launch-capture-2026-09-23]].** The Launch reads live values via service **`2C`** (dynamicallyDefineLocalIdentifier), not `21`/`22`: poll `2C 10 00 DF` → reply `6C 10 HHLL`. **Rail pressure actual is fully decoded and verified: bar = HHLL × 0.03** (two points against the Launch display: idle 305, 2500 rpm 430). The method generalises to any value the Launch will display; self-polling it would need the connect-time session/define handshake (captured, but a transmit-on-the-bus design decision).
**Capture-with-Launch done, and it worked — [[launch-capture-2026-09-23]].** The Launch reads live values via service **`2C`** (dynamicallyDefineLocalIdentifier), not `21`/`22`: poll `2C 10 00 DF` → reply `6C 10 HHLL`. **Rail pressure actual is fully decoded and verified: bar = HHLL × 0.03** (two points against the Launch display: idle 305, 2500 rpm 430). The method generalises to any value the Launch will display. Crucially, the capture shows the DDE served this in its **default state — no `10` session, no `27` security, no `3E` tester-present** ([[launch-capture-2026-09-23]]); self-polling needs only the `2C 10 15 E0` define + `2C 10 00 DF` poll, no secret. What gates it is our own policy, not the ECU (see *Beyond the probe*).
This depends on the DDE variant, which is still open ([[open-questions]] #2, [[bmw-m57n-engine]]):
@@ -126,7 +126,9 @@ Run via `tools/diag_session.py` (one serial session, logs straight into `wiki/ra
## Beyond the probe `(repo)`
- **The decode recipe (proven 2026-09-23):** log `CANRAW` while the Launch shows a live value → find the `2C 10 <id>` / `6C 10 <data>` pair whose data tracks the reading → calibrate scale against the display at two operating points (idle + a blip). One session per parameter. Boost, MAF, injection quantity, EGTs all reachable this way. Worked example: [[launch-capture-2026-09-23]] (rail pressure).
- A continuous poller (Route A or B) would reuse the same transmit path with a fixed request list: one request per ≥100 ms, one identifier at a time, only while no scan tool is connected, never a session-control or write service. Still a design decision: a request storm or a malformed frame can disturb the DDE/EGS, and diagnostic sessions can change what an ECU broadcasts. **Route B self-polling additionally needs the connect-time session/define handshake** the Launch performs (the blind `21` scan hit NRC 0x22/0x33 without it) — captured in [[launch-capture-2026-09-23]] if we ever choose to replay it.
- A continuous poller (Route A or B) would reuse the same transmit path with a fixed request list: one request per ≥100 ms, one identifier at a time, only while no scan tool is connected, never a session-control or write service. Still a design decision: a request storm or a malformed frame can disturb the DDE/EGS.
- **What Route B self-polling actually requires (settled 2026-09-23):** just the `2C 10 15 E0` define then the `2C 10 <id>` poll — **no diagnostic session (`10`), no security access (`27`), no tester-present (`3E`)**, proven from the full Launch capture ([[launch-capture-2026-09-23]]). The `21`-block NRCs (0x22/0x33) that earlier looked like a session/security wall are a *different mechanism* and do not gate the `2C` path. `2C` is not strictly read-only (it writes a dynamic-identifier definition — harmless), so it stays out of the probe whitelist by policy.
- **Design decision — the "Diagnostics" screen (2026-09-23):** if active polling is ever built, it lives behind a **password-protected Diagnostics screen** on Controller A (authorized-technician gate), triggered manually, only while no scan tool is connected, read-oriented services only. This is the deliberate on/off switch for transmit-on-the-bus — not a background poller. Not built yet; captured here so the capability and its guard rails are not re-researched later.
- Protocol v2 dropped the `fault_codes` field in favour of the alert bitmap ([[dual-controller-architecture]]); polled values would need new DATA fields.
- The same request path would also be the only way to read DTCs (service `0x18`/`0x19`, variant-dependent) → [[open-questions]] #7.
+4
View File
@@ -22,6 +22,10 @@ The research frontier. Answering any of these should trigger updates across the
10. **What are the Patrol's final drive ratio and tyre size?** Needed to turn output-shaft rpm into road speed. Swap-specific — not in any donor documentation. → [[nissan-patrol-swap]]
## Design decisions (parked, not blocking)
12. **The "Diagnostics" screen (planned 2026-09-23).** Active diagnostic polling — replaying the `2C` live-data reads we decoded ([[launch-capture-2026-09-23]]) so values like rail pressure appear on Controller A without the Launch — is now technically unblocked (no session/security needed). Intended design when built: a **password-protected Diagnostics screen**, authorized-technician access only, manual trigger, refuses while a scan tool is connected, read-oriented services only. The same gate covers the general transmit-on-the-bus decision. This is deliberately deferred, but the capability, the byte sequences, and these guard rails are recorded so the work resumes from here, not from scratch. → [[obd-diagnostic-polling]], [[dual-controller-architecture]]
## Project context
2. **Exact donor model year / DDE version and EGS variant?** *Partly answered 2026-07-17.* The gearbox is a **ZF 6HP26X** (user-confirmed) — the X is the xDrive output variant, which means the donor is an **E60/E61, not an E65**: the 7-series never took M57N + xDrive. Remaining: model year and DDE version. **Cheap to close (2026-09-21):** the Launch scanner's ECU-identification page (or any INPA "control unit found" string) names the variant — `D60M57D0`/`D62M57B0` = DDE6 (EDC16), `D73N57C0` = DDE7.3 (EDC17). **Update 2026-09-23:** generic OBD can NOT close this — mode 09 (VIN `09 02`, ECU name `09 0A`) is ACKed but never answered ([[diag-route-a-2026-09-23]]). **Same afternoon, mostly ANSWERED via Route B**: `1A 86` on `0x6F1` returned the DDE ident — **VIN prefix `WBANC92090` → E60 530d** `(unverified decode)`, DDE part numbers **7 799 764 / 7 799 765 / 7 793 887**, date 2006-03, and the DDE speaks **KWP2000 not UDS** ([[diag-route-b-2026-09-23]]). Remaining sliver: look up the part numbers / NC9x model code online to pin the exact DDE variant (DDE6.1 vs 6.2, M57N vs M57N2) — a web/parts-catalogue task now, no more hardware needed. → [[bmw-m57n-engine]], [[obd-diagnostic-polling]]