Gauge drive day: CANNY comparison, cluster signal research, serial tools
Wiki: two new pages - canny-5-3-pico-gauge-drive (why the CANNY's 12V negative output moved the needles and 3.3V push-pull could not; 2SK3069 low-side stage) and patrol-instrument-cluster (tach 2 ppr + trim -13 calibration, NTC temp sender curve, 20 kHz PWM flutter fix, and the four-layer steppy-needle diagnosis ending at the cluster's ~150 rpm count quantization, defeated with adaptive dither on B). Tools: serial_logger.py (multi-port capture to wiki/raw), serial_cmd.py (one-shot cfg commands to A), dual_serial_capture.py (bench snapshots), tach_ramp.py / tach_ramp2.py (synthetic rpm sweeps via cfg override). Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,60 @@
|
||||
---
|
||||
type: synthesis
|
||||
tags: [hardware, gauges, nissan-patrol, controller-b, electronics]
|
||||
updated: 2026-09-22
|
||||
---
|
||||
|
||||
# CANNY 5.3 pico vs ESP32-S3: driving the Patrol cluster
|
||||
|
||||
Why the user's old CANNY-based setup moves the Patrol tach and our ESP32 (Controller B, IO7) does not. Researched 2026-09-22 after the first in-car test of the dual-controller rig: temp needle parked mid-scale, tach dead ([[dual-controller-architecture]]).
|
||||
|
||||
## The working reference setup `(verified)`
|
||||
|
||||
The user previously drove this same instrument cluster with a **CANNY 5.3 pico** (Russian visual-PLC automotive controller, cannylogic.com / canny.ru), using **"Default Negative Output" in DIO mode on IO channel 8** (contact 4 — the channel that also carries the high-resolution PWM function). The cluster's needles respond in that setup — this is our known-good electrical reference.
|
||||
|
||||
## What the CANNY output stage is (source: cannylogic.com/docs/c53pico, canny.ru)
|
||||
|
||||
- Channels are **12 V-domain**: "output operating voltage on the controller channels matches the supply voltage" (7–16 V, 18 V abs max).
|
||||
- Each channel is a **configurable-polarity switch**: "positive" mode connects the line to +12 V (high-side source), **"negative" mode connects the line to GND (low-side sink)**. Two strengths: weak ~1 mA (pull) and strong 100 mA.
|
||||
- Rated for inductive/resistive/capacitive loads, 100 mA per channel, 300 mA total, automatic shutoff on over-current.
|
||||
- "Negative output" therefore produces the classic automotive sender signal: the line is **pulled to ground when active and floats up to the cluster's own internal pull-up (~battery) when released** — a 0 ↔ ~12 V swing without the controller ever sourcing voltage.
|
||||
|
||||
## What our ESP32-S3 GPIO is
|
||||
|
||||
- **3.3 V push-pull** logic pin, absolute max ~3.6 V, source/sink a few tens of mA, no protection `(unverified — standard ESP32-S3 datasheet values)`.
|
||||
- LEDC PWM on B's IO7 (tach square wave) and IO8 (temp duty) drives the line **actively to 3.3 V and 0 V** `(repo)`.
|
||||
|
||||
## Why this explains the test-day symptoms `(verified 2026-09-22 for the tach — needle tracks rpm through the 2SK3069 low-side stage; see [[patrol-instrument-cluster]] for calibration)`
|
||||
|
||||
- The Patrol tach input expects negative-going pulses on a line it pulls up internally toward battery. With the ESP32 push-pull output attached, the "high" half of every cycle is **3.3 V instead of ~12 V** — likely below the input threshold, so the tach sees no edges at all → dead needle, exactly what the CANNY's negative output provides and we don't.
|
||||
- The temp gauge input is a sender-resistance-to-ground circuit. A 3.3 V push-pull PWM can bias it to some fixed effective level — a needle that parks at one position and ignores duty changes is consistent with this (mid-scale at 89 °C may have been coincidence, not the duty law working). Re-test after the drive stage is fixed before trusting the temp calibration in [[dual-controller-architecture]].
|
||||
- **It is not PWM polarity in firmware**: a 50 % square wave is its own inverse, and inverted temp duty would move the needle backwards, not freeze it.
|
||||
|
||||
## The fix (per channel): replicate "negative output"
|
||||
|
||||
Small low-side switch between the ESP32 pin and the gauge line:
|
||||
|
||||
```
|
||||
gauge line ──────────────┬──── (cluster's internal pull-up to ~12 V)
|
||||
│
|
||||
D (drain/collector)
|
||||
ESP32 IOx ──[R ~1k]── G/B N-MOSFET (logic-level, e.g. 2N7002/AO3400) or NPN (2N2222 + base R)
|
||||
S (source/emitter)
|
||||
│
|
||||
GND (common with cluster!)
|
||||
```
|
||||
|
||||
- ESP32 high → line pulled to GND; ESP32 low → line released to the cluster's pull-up. This **inverts the logic**: tach unaffected (50 % square), temp duty becomes 255 − duty at the gauge — recalibrate `temp_slope`/`temp_offset` ([[dual-controller-architecture]] tunables) or invert in B's firmware.
|
||||
- If the cluster input turns out to have no internal pull-up, add an external ~4.7–10 kΩ to +12 V.
|
||||
- On hand (2026-09-22): a **2SK3069** (N-ch, 60 V / 75 A, 4 V-drive class) — hugely oversized but suitable; planned for the tach channel with 220 Ω gate series + 10 kΩ gate pulldown `(source: alltransistors.com 2SK3069)`.
|
||||
- **Never** connect the 12 V-pulled gauge line directly to an ESP32 pin, including in open-drain mode — the pin is not 12 V tolerant.
|
||||
- Grounds must be common: cluster GND ↔ Controller B GND.
|
||||
|
||||
## Open items
|
||||
|
||||
- Scope or multimeter the tach line at rest: does it float high (~12 V) with nothing attached? Confirms the internal pull-up assumption.
|
||||
- After the transistor stage: re-run the override test (Force tach rpm / Force coolant duty on A's tuning screen) and re-derive the temp duty law; promote this page's hypothesis to `(verified)`.
|
||||
|
||||
## Related
|
||||
|
||||
[[dual-controller-architecture]] · [[nissan-patrol-swap]] · [[open-questions]]
|
||||
Reference in New Issue
Block a user