OTA updates for Controller A: dual-slot partitions, signed Gitea releases

- partition table: two 7.9 MB OTA slots, SPIFFS dropped, nvs/otadata offsets
  unchanged (tunables survived the one-time USB flash)
- ota_update.cpp: manual `ota status|check|install|rollback` console; HTTPS
  pull from the public repo's latest release, ECDSA P-256 signature over
  "patrol-a|version|sha256" checked before download, streamed image must match,
  parked gate before download and before the slot switch, 30 s
  confirm-or-rollback (verifyRollbackLater override)
- ota_config.h: server/repo, ISRG Root X1 + Root YR, signing public key
- .gitea/workflows/firmware.yml: main -> rolling unsigned pre-release
  main-latest; v* tag -> signed release (needs secret FIRMWARE_SIGNING_KEY)
- wiki: pages/ota-updates.md (design, decisions, B-over-ESP-NOW plan);
  CLAUDE.md, index, log, open-questions #12 updated

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-09-26 21:59:46 +02:00
parent da4c96903b
commit effa949429
12 changed files with 915 additions and 14 deletions
+2 -2
View File
@@ -1,7 +1,7 @@
---
type: synthesis
tags: [meta, todo]
updated: 2026-09-23
updated: 2026-09-26
---
# Open Questions
@@ -24,7 +24,7 @@ The research frontier. Answering any of these should trigger updates across the
## Design decisions (parked, not blocking)
12. **The "Diagnostics" screen (planned 2026-09-23).** Active diagnostic polling — replaying the `2C` live-data reads we decoded ([[launch-capture-2026-09-23]]) so values like rail pressure appear on Controller A without the Launch — is now technically unblocked (no session/security needed). Intended design when built: a **password-protected Diagnostics screen**, authorized-technician access only, manual trigger, refuses while a scan tool is connected, read-oriented services only. The same gate covers the general transmit-on-the-bus decision. This is deliberately deferred, but the capability, the byte sequences, and these guard rails are recorded so the work resumes from here, not from scratch. → [[obd-diagnostic-polling]], [[dual-controller-architecture]]
12. **The "Diagnostics" screen (planned 2026-09-23).** Active diagnostic polling — replaying the `2C` live-data reads we decoded ([[launch-capture-2026-09-23]]) so values like rail pressure appear on Controller A without the Launch — is now technically unblocked (no session/security needed). Intended design when built: a **password-protected Diagnostics screen**, authorized-technician access only, manual trigger, refuses while a scan tool is connected, read-oriented services only. The same gate covers the general transmit-on-the-bus decision. This is deliberately deferred, but the capability, the byte sequences, and these guard rails are recorded so the work resumes from here, not from scratch. **Also the home of the OTA "check / install" controls (2026-09-26)** — today they are the `ota` console; the password must be stored as a salted hash in NVS because the firmware is public. → [[obd-diagnostic-polling]], [[dual-controller-architecture]], [[ota-updates]]
## Project context