wiki: Add live-capture field checklist to CAN ID candidates
This commit is contained in:
@@ -27,6 +27,23 @@ Findings from the 2026-07-15 deep-research run (95 claims extracted from ~15 sou
|
|||||||
- **E65 live capture** (damienmaguire, verified against code): whole byte 0 = 0xE1=P, 0xD2=R, 0xB4=N, 0x78=D; byte 3 is a rolling counter 0x0D→0xED in steps of 0x10. DLC **5**.
|
- **E65 live capture** (damienmaguire, verified against code): whole byte 0 = 0xE1=P, 0xD2=R, 0xB4=N, 0x78=D; byte 3 is a rolling counter 0x0D→0xED in steps of 0x10. DLC **5**.
|
||||||
- Same ID, different generation dialects — the E60 could speak either. Note the E65 byte-0 values are consistent with the E90 nibble scheme (0xE1 low nibble = 1 = P, 0xD2 → 2 = R, 0xB4 → 4 = N, 0x78 → 8 = D, high nibble = XOR-inverted copy!) — so the two sources may actually agree and the "dispute" is notation. Bench capture decides.
|
- Same ID, different generation dialects — the E60 could speak either. Note the E65 byte-0 values are consistent with the E90 nibble scheme (0xE1 low nibble = 1 = P, 0xD2 → 2 = R, 0xB4 → 4 = N, 0x78 → 8 = D, high nibble = XOR-inverted copy!) — so the two sources may actually agree and the "dispute" is notation. Bench capture decides.
|
||||||
|
|
||||||
|
## Field checklist for the live capture session
|
||||||
|
|
||||||
|
Setup: 500 kbps, listen-only, board's 120 Ω termination switch **OFF**, tap CAN-H/CAN-L on the PT-CAN. **Log everything raw for the whole session** and save the dump into `wiki/raw/` — even IDs we don't care about yet.
|
||||||
|
|
||||||
|
| Test | Watch | Confirms |
|
||||||
|
|------|-------|----------|
|
||||||
|
| Ignition on, engine off | `0x130` byte 0 changes per key position; `0x3B4` appears (~every 5 s) | Terminal status; battery message alive |
|
||||||
|
| Compare `0x3B4` to a multimeter at the battery | Try 12-bit LE ×0.015 and ×0.0147 vs meter (engine off ≈12.4 V, running ≈14+ V); check byte 3 flips 0x00→0x09 on start | Battery layout + factor; engine-running flag |
|
||||||
|
| Cold start, note ambient temp | `0x1D0` byte 0 ≈ ambient+48 raw, then climbs steadily to ~90 °C (raw ~0x8A) | Coolant ID + −48 scaling |
|
||||||
|
| Same, byte 1 | Should ALSO start near ambient but climb **slower** than byte 0 and lag behind | Oil temp really is byte 1 (weakest engine signal) |
|
||||||
|
| Cold start | `0x0B5` byte 7: if raw ≈ ambient → offset 0; if raw ≈ ambient+40… i.e. reads 40 under ambient with offset 0 assumed → offset +40 | Gearbox temp offset dispute (cold start makes the two hypotheses ~40 apart — unmistakable) |
|
||||||
|
| Hold brake, shift P→R→N→D→(S/M) slowly | `0x1D2` byte 0 (note DLC: 5 vs 6!); `0x304` bytes; `0x0BA` bits 0–3 | Gear lever encoding + which message to use; settles the D=R typo in the E60 sheet |
|
||||||
|
| Drive: let the box shift 1→2→3… | `0x1D2` byte 1 upper nibble, `0x0BA` low nibble increments per shift | Current gear number source |
|
||||||
|
| Blip throttle | `0x0AA` bytes 4–5 = RPM×4 | RPM sanity check (fast cross-check that you're on the right bus) |
|
||||||
|
|
||||||
|
If an expected ID is absent entirely, note it — it means the swap harness dropped that module's traffic, which is itself an answer ([[open-questions]] #3).
|
||||||
|
|
||||||
## Fault codes: passive reading is NOT possible ⚠
|
## Fault codes: passive reading is NOT possible ⚠
|
||||||
|
|
||||||
Consistent across sources: **no DTC/fault-code broadcast exists**. The `dieslg8` project (M57 diesel, later EDC17 DDE) gets coolant temp and DTCs only via **active diagnostic requests** (send on 0x6F1, parse responses on 0x612; e.g. coolant = raw×0.01 − 100). At most, a **MIL/check-engine lamp status bit** may be passively derivable (a commercial Patrol-swap CAN module offers a check-engine output). Consequences for the firmware `(repo)`:
|
Consistent across sources: **no DTC/fault-code broadcast exists**. The `dieslg8` project (M57 diesel, later EDC17 DDE) gets coolant temp and DTCs only via **active diagnostic requests** (send on 0x6F1, parse responses on 0x612; e.g. coolant = raw×0.01 − 100). At most, a **MIL/check-engine lamp status bit** may be passively derivable (a commercial Patrol-swap CAN module offers a check-engine output). Consequences for the firmware `(repo)`:
|
||||||
|
|||||||
Reference in New Issue