- capture proof: Launch used only 1A/2C/22/23 - no 10/27/3E. Self-polling a 2C live value needs just the define + poll, no session or security seed. Corrected the earlier "needs session handshake" wording. - design decision: active polling (if built) lives behind a password- protected Diagnostics screen - authorized-tech gate, manual, refuses with a scan tool connected, read-oriented services. open-questions #12. - wiki: launch-capture + obd-diagnostic-polling tightened; project memory added so the capability and guard rails are not re-researched later Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
15 KiB
type, tags, updated
| type | tags | updated | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| concept |
|
2026-09-23 |
OBD / Diagnostic Polling
Why some values never appear on the sniffer, how a scan tool gets them, and what it would take for Controller A to do the same. Several pages have linked here since July (can-id-candidates, open-questions #7); the page was created on the google-ai-dde7m57-pids ingest, 2026-09-21.
Broadcast vs polled
- The DDE and EGS broadcast only what other modules need to run the car: rpm, coolant, gear, gearbox temp, torque, pedal, battery… — the verified list is in can-id-candidates.
- Not broadcast (verified by absence on our own bus): manifold boost (
AIP_ENGon0x1D0is barometric), MAF, rail pressure, injection quantity, fault codes. The Launch scanner shows them because it polls the ECU and displays the answers. - Consequence: a listen-only display can never show these. Getting them means transmitting requests on the PT-CAN.
How a tester talks to the DDE on this bus
E60-generation BMWs use one shared diagnostic ID pair with an ECU address in the first payload byte (BMW's extended-addressing variant of ISO 15765):
| Direction | CAN ID | First payload byte | Then | Evidence |
|---|---|---|---|---|
| Tester → any ECU | 0x6F1 |
target address (DDE = 0x12, EGS = 0x18 (unverified)) |
len, service, data |
(source: dieslg8 via can-id-candidates) |
| ECU → tester | 0x600 + address → DDE 0x612, EGS 0x618 |
0xF1 |
len, service + 0x40, data |
same |
- What the user saw (2026-09-21):
0x612appears on the tapped bus only while the Launch is connected. That is the DDE answering — consistent with the table. The requests should be present in the same capture as0x6F1; the user's recollection of "0x6F2" is almost certainly0x6F1.
Note
Resolved 2026-09-23: our own probe sent
0x6F1 [12] 1A 86and the DDE answered on0x612(verified)— dieslg8's scheme was right, the google-ai-dde7m57-pids clipping's reversed claim is dead. See diag-route-b-2026-09-23.
- Generic EOBD (
0x7DFfunctional → reply0x7E8, mode01) is a second, standard route —(verified 2026-09-23): the DDE answers it on the PT-CAN. See Route A results below.
Route A — generic OBD-II mode 01 — VERIFIED WORKING (2026-09-23)
First live run done, engine idling, probe on the tapped bus: the DDE replies on 0x7E8 (and only the DDE — the EGS stays silent on generic OBD). Full readings, raw logs and the two scaling warnings: diag-route-a-2026-09-23.
- Supported PIDs (bitmap scan):
01, 04, 05, 0B, 0C, 0D, 0F, 10, 1C, 20, 21— a minimal EOBD set, consistent with EDC16/DDE6(unverified). No boost70, no EGT78, no baro33, no fuel rate5E. - Cross-checked live: rpm 681 (CAN said 678–682) and coolant 64 °C (CAN said 63–64) — request path and decode both
(verified). - MAP
0B= 104 kPa at idle; the 255 kPa clip question needs a drive with boost. - MAF
10and IAT0Freply with implausible values (258 g/s, 155 °C at idle) — explained the same afternoon: those are sensor faults (P0101, P0113), not scalings (diag-route-b-2026-09-23). - Mode 09 (VIN, ECU name) is ACKed but never answered — the donor could not be identified via generic OBD; Route B's
1A 86did it instead. - PID
01reports MIL off with 5 stored DTCs — read the same day via the newdiag dtc(mode 03): P0101, P0113, P0500, P0545, P0030, all swap leftovers (diag-route-b-2026-09-23).
The original pre-test notes and PID reference table follow.
The dwr-335d-torque-pids source is a worked, gauge-checked set of J1979 mode-01 PIDs from an M57 diesel (a 2009 335d, DDE7.3). They are ECU-agnostic by design, so whichever subset our DDE supports can be read with standard frames and no reverse-engineering:
Request on 0x7DF |
Reply on 0x7E8 |
Value |
|---|---|---|
02 01 00 |
06 41 00 A B C D |
bitmap of supported PIDs 01–20 (then 01 20, 01 40, 01 60 for the next blocks) |
02 01 05 |
03 41 05 A |
coolant A − 40 °C |
02 01 0B |
03 41 0B A |
manifold absolute pressure, A kPa — clips at 255 kPa, below full boost |
02 01 0C |
04 41 0C A B |
rpm (A·256+B)/4 |
02 01 0F / 01 46 |
03 41 xx A |
intake / ambient air temp A − 40 °C |
02 01 10 |
04 41 10 A B |
MAF (A·256+B)/100 g/s |
02 01 33 |
03 41 33 A |
barometric A kPa |
02 01 5E |
04 41 5E A B |
fuel rate (A·256+B)×0.05 L/h |
02 01 70 |
0A 41 70 A B C D E … |
boost actual (D·256+E)×0.03125 kPa — 2007+ J1979 diesel PID, likely absent on an EDC16 (unverified) |
02 01 73 / 78 / 7A / 83 |
— | exhaust pressure / EGT / DPF ΔP / NOx — same caveat; DPF/SCR rows are meaningless on an M57N anyway |
- First test = the
01 00bitmap query. One frame on0x7DFwith the engine running (no scan tool attached) answers both open points at once: does this DDE speak EOBD on the PT-CAN at all, and which PIDs does it offer. No reply → the DDE serves EOBD on K-line (or not on this bus) and only Route B remains. - Implemented on Controller A (2026-09-21)
(repo)as thediagconsole command — see Firmware: thediagprobe below. The whole test isdiag pidstyped on the USB console. - Route A cannot give fault codes beyond generic mode
03DTCs (P0xxx) — BMW-specific codes need Route B.
Route B — BMW proprietary (KWP2000 on 0x6F1 → 0x612) — VERIFIED WORKING (2026-09-23)
First live exchange without any scan tool: diag bmw 12 1A 86 → 65-byte multi-frame ident from 0x612, containing DDE part numbers (7 799 764 / 7 799 765 / 7 793 887), a 2006-03 date, and the VIN prefix WBANC92090 → E60 530d (verified bytes / unverified decode) — full breakdown in diag-route-b-2026-09-23. 22 F1 90 (UDS) is rejected: the DDE speaks KWP2000, not UDS — pointing at DDE6/EDC16. 1A 90 (full VIN) answers busyRepeatRequest to a single-shot probe. Same day, identifier scans: the clipping's 22 D1xx identifiers are confirmed wrong (whole block NRCs), and a 21 xx sweep shows the measurement blocks are gated behind a diagnostic session / security access (NRC 0x22/0x33) — outside the probe's read-only whitelist by design.
Capture-with-Launch done, and it worked — launch-capture-2026-09-23. The Launch reads live values via service 2C (dynamicallyDefineLocalIdentifier), not 21/22: poll 2C 10 00 DF → reply 6C 10 HHLL. Rail pressure actual is fully decoded and verified: bar = HHLL × 0.03 (two points against the Launch display: idle 305, 2500 rpm 430). The method generalises to any value the Launch will display. Crucially, the capture shows the DDE served this in its default state — no 10 session, no 27 security, no 3E tester-present (launch-capture-2026-09-23); self-polling needs only the 2C 10 15 E0 define + 2C 10 00 DF poll, no secret. What gates it is our own policy, not the ECU (see Beyond the probe).
This depends on the DDE variant, which is still open (open-questions #2, bmw-m57n-engine):
| DDE | ECU | Typical fitment | Ediabas group | Diagnostic layer |
|---|---|---|---|---|
| DDE6.x | Bosch EDC16C31/C35 | E60/E61 M57N 2003–07 (our likely donor) | D60M57D0 / D62M57B0 |
KWP2000 on CAN (unverified) |
| DDE7.3 | Bosch EDC17CP09 | E90 335d / E70 35d (M57N2, NA market) | D73N57C0 |
KWP2000 on CAN, UDS variant exists (unverified) |
- The clipping's identifiers (
22 D1 0Cboost,22 D1 1Erail,22 D1 14MAF,22 D1 06injection) are(unverified)and uncited — do not implement from them. The Ediabas result names (STAT_LADEDRUCK_IST_WERT,STAT_RAILDRUCK_IST_WERT,STAT_LUFTMASSE_WERT,STAT_EINSPRITZMENGE_AKTUELL_WERT,STAT_KUEHLMITTELTEMPERATUR_WERT,STAT_MOTORDREHZAHL_WERT) are real and are the right search terms. - The reliable route needs no guessing: capture while the Launch is on its live-data page (procedure below). The exact request bytes and the reply layout come for free, for whatever variant is in the car.
Procedure: capture with the Launch polling
- Start the board's raw logger (
CANRAWstream, see can-bus-integration) with the Launch connected; open the Launch's live-data page for boost or rail pressure; blip the throttle twice. - Filter the log to
0x6F1and0x612(also keep0x7E0/0x7E8and0x618if they show up). - Pair each
0x6F1request with the0x612reply that follows. In the reply, the byte after the length is the service +0x40(0x62for a0x22request,0x61for0x21); the identifier is echoed next; the data bytes follow. Match the bytes that move with the throttle to the values the Launch displayed. - Open the Launch's ECU identification page and note the variant string — closes open-questions #2.
- File the log in
raw/, write a source page, promote whatever pairs were seen to(verified).
Firmware: the diag probe (repo, 2026-09-21)
Controller A now has one transmit path onto the PT-CAN: CANDriver::transmit(), called only by src/modules/diag_probe.cpp. It sends nothing on its own; every frame is typed by a human on the USB console.
| Command | What it sends | What it prints |
|---|---|---|
diag pids |
02 01 00 on 0x7DF, then 01 20, 01 40… as long as the engine ECU advertises the next block |
each block's supported PIDs, then a per-responder summary with names (coolant, rpm, MAP, MAF, boost 70, EGT 78…) |
diag pid <hex> |
one mode-01 request | raw reply bytes + a decoded value for the PIDs in the Route A table |
diag vin |
mode 09 PID 02 | the VIN as text — identifies the donor (open-questions #2) |
diag ecu |
mode 09 PID 0A | the ECU name string |
diag dtc |
mode 03 on 0x7DF |
the stored generic DTCs, decoded (added 2026-09-23) |
diag ident [addr] |
BMW KWP 1A 80 on 0x6F1 (default addr 12 = DDE) |
ECU identification, full hex+ASCII dump (added 2026-09-23) |
diag bmw <addr> <hex...> |
one raw BMW-addressed request | reply dump; whitelisted read-only services only (1A ident, 18 DTCs, 21/22 read data — never session control or writes) |
diag status |
nothing | request/reply/timeout counters, responders seen, tester-guard timer |
Safety rules baked in: one request in flight at a time; frames are single-shot (no retransmit storm if nobody ACKs, the failure is just counted); refused for 3 s after any foreign tester frame (0x7DF, 0x7E0–7, 0x6F1), so it cannot collide with the Launch; only services 01 and 09, never session control or writes; multi-frame replies are reassembled with a standard flow-control frame (30 00 00) to the responder's physical ID. Every transmitted frame is echoed as CANTX,<ts>,<id>,0,<dlc>,<hex> next to the CANRAW lines, so a saved console log holds both halves of every exchange.
Test-day procedure (Route A probe) — executed 2026-09-23, outcome: Route A works
Run via tools/diag_session.py (one serial session, logs straight into wiki/raw/); results in diag-route-a-2026-09-23. Procedure kept for re-runs (e.g. the boost-clip drive test):
- Engine running, Launch unplugged (the probe refuses to send for 3 s after any tester frame, and the Launch keeps polling while attached).
- Laptop on the 5B's USB, console at 115200 with the output saved to a file, e.g. from the repo root:
(or any terminal with logging on). The
pio device monitor -p COM11 --quiet > diag-<date>.logCANRAWstream keeps running; thediaglines andCANTXechoes land in the same file. - Type
diag pids. Read the summary line — four possible outcomes:- "NOT ACKED - no other node saw it" → wiring or bus problem, not an ECU answer. Check the CAN terminal block, the 120 Ω switch (off), and that
CANRAWlines are still flowing. - "ACKED but NO REPLY on 0x7E8-0x7EF" → the DDE does not answer generic OBD-II on this bus (EOBD on K-line, or not at all). Route B only.
- Reply from
0x7E8listing PIDs → Route A works. Continue with step 4. - Replies from
0x7E8and0x7E9→ the EGS also answers generic OBD; note which PIDs it claims.
- "NOT ACKED - no other node saw it" → wiring or bus problem, not an ECU answer. Check the CAN terminal block, the 120 Ω switch (off), and that
- If Route A works:
diag pid 0C(rpm — proves a live read),diag pid 05(coolant — cross-check against the0x1D0value on the Driveline screen),diag pid 70(does the boost PID exist on this ECU?),diag pid 0B(does 1-byte MAP clip?), thendiag vinanddiag ecu. diag statusonce at the end (counters, tester guard), then stop the monitor.- Copy the log into
raw/, write asources/page with the supported-PID list and the VIN, update this page (Route A verified / refuted) and open-questions #2 and #7.
Beyond the probe (repo)
- The decode recipe (proven 2026-09-23): log
CANRAWwhile the Launch shows a live value → find the2C 10 <id>/6C 10 <data>pair whose data tracks the reading → calibrate scale against the display at two operating points (idle + a blip). One session per parameter. Boost, MAF, injection quantity, EGTs all reachable this way. Worked example: launch-capture-2026-09-23 (rail pressure). - A continuous poller (Route A or B) would reuse the same transmit path with a fixed request list: one request per ≥100 ms, one identifier at a time, only while no scan tool is connected, never a session-control or write service. Still a design decision: a request storm or a malformed frame can disturb the DDE/EGS.
- What Route B self-polling actually requires (settled 2026-09-23): just the
2C 10 15 E0define then the2C 10 <id>poll — no diagnostic session (10), no security access (27), no tester-present (3E), proven from the full Launch capture (launch-capture-2026-09-23). The21-block NRCs (0x22/0x33) that earlier looked like a session/security wall are a different mechanism and do not gate the2Cpath.2Cis not strictly read-only (it writes a dynamic-identifier definition — harmless), so it stays out of the probe whitelist by policy. - Design decision — the "Diagnostics" screen (2026-09-23): if active polling is ever built, it lives behind a password-protected Diagnostics screen on Controller A (authorized-technician gate), triggered manually, only while no scan tool is connected, read-oriented services only. This is the deliberate on/off switch for transmit-on-the-bus — not a background poller. Not built yet; captured here so the capability and its guard rails are not re-researched later.
- Protocol v2 dropped the
fault_codesfield in favour of the alert bitmap (dual-controller-architecture); polled values would need new DATA fields. - The same request path would also be the only way to read DTCs (service
0x18/0x19, variant-dependent) → open-questions #7.
Related