- capture proof: Launch used only 1A/2C/22/23 - no 10/27/3E. Self-polling a 2C live value needs just the define + poll, no session or security seed. Corrected the earlier "needs session handshake" wording. - design decision: active polling (if built) lives behind a password- protected Diagnostics screen - authorized-tech gate, manual, refuses with a scan tool connected, read-oriented services. open-questions #12. - wiki: launch-capture + obd-diagnostic-polling tightened; project memory added so the capability and guard rails are not re-researched later Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
4.4 KiB
type, tags, updated
| type | tags | updated | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| source |
|
2026-09-23 |
Launch live-data capture — rail pressure decoded (2026-09-23)
The capture-with-Launch session that obd-diagnostic-polling had been pointing at since July, finally run. Engine idling, our read-only logger (tools/serial_logger.py) on Controller A's USB recording the full CANRAW stream while the Launch polled the DDE; then the user selected Rail Pressure (actual) and blipped to 2500 rpm for a second calibration point. Raw: raw/serial-COM10-20260923-163511.log (~13 MB, both halves of every exchange).
Headline: rail pressure actual is decoded and VERIFIED
(verified 2026-09-23, two operating points against the Launch display)
| Direction | CAN ID | Payload | Meaning |
|---|---|---|---|
| Launch → DDE | 0x6F1 |
12 04 2C 10 00 DF |
target 12 (DDE), 4-byte req, service 2C local-id 10, operand 00 DF |
| DDE → Launch | 0x612 |
F1 04 6C 10 HH LL |
6C = 2C+0x40, id 10, then 16-bit rail value HHLL |
Rail pressure (bar) = (HH·256 + LL) × 0.03 — linear through zero, no offset.
Calibration points (sustained, not transient):
- idle: raw
0x27EF(10223) → 307 bar vs Launch ~305 ✓ - 2500 rpm: raw
0x3768(14184) → 425 bar vs Launch ~430 ✓ - factor from the two points: 0.0298 and 0.0303 → adopt 0.03 bar/count (≈ raw / 33.3)
Transient spikes to 0x4E31 (20017 → 600 bar) occurred at the instant of throttle tip-in (rail overshoot); they are real but not the steady value the gauge reads.
How the Launch reads it — the mechanism (observed 2026-09-23)
The live poll is service 2C (KWP dynamicallyDefineLocalIdentifier family): on connect the Launch sends 2C 10 15 E0 once (define), then polls 2C 10 00 DF repeatedly (~200 ms), each returning a fresh 6C 10 HHLL. So the value ID 00 DF is the rail-pressure block. Interpreting 00 DF / 15 E0 as memory addresses vs block numbers is unconfirmed — for replay only the request bytes matter. The Launch also runs a constant 1A 80 ident keep-alive and did 22/23 (readData / readMemoryByAddress) reads on connect (ident/programming data, ASCII "090" etc.).
Services the Launch used — and did NOT use (verified from the full capture)
Every 0x6F1 request in the ~13 MB log, by service: 1A (ident keep-alive), 2C (live-data define/read), 22/23 (connect-time ident/memory), plus flow control. Absent entirely: 10 StartDiagnosticSession, 27 SecurityAccess, 3E TesterPresent.
This is the key operational finding: rail pressure is served in the DDE's default state — no diagnostic session, no security seed/key, no tester-present keep-alive. The earlier 21 xx NRCs (0x22 conditions-not-correct, 0x33 security-denied) in diag-route-b-2026-09-23 were specific to the 21 read-by-local-id mechanism — a different door — and do not apply to the 2C path. There is no secret algorithm between us and this value.
Consequences
- The method generalises: any value the Launch will display can be decoded the same way — capture the
2C/6Cpair while its screen shows the number, calibrate scale against the display at two points. Boost, MAF, injection quantity, EGTs are each one session away. See obd-diagnostic-polling "Beyond the probe". - Self-poll is feasible without any secret. To read rail pressure ourselves: send the one-time define
2C 10 15 E0, then poll2C 10 00 DF→ parse6C 10 HHLL. No10session, no27security, no3Etester-present required (proven above). The only barriers are our own choices, not the ECU's — see the two below. - It is still a transmit-on-the-bus action, and
2Cis not strictly read-only (it writes a definition into the ECU's dynamic-identifier table — harmless, but a state change). So it stays outside the current probe whitelist by policy. - Intended home (design decision, 2026-09-23): any active polling belongs behind a password-protected "Diagnostics" screen on Controller A — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records open-questions; not built yet.
- No EGS traffic (
0x618) — only the DDE (0x612) answered; the Launch was on an engine page.
Related
obd-diagnostic-polling · diag-route-b-2026-09-23 · diag-route-a-2026-09-23 · bmw-m57n-engine · open-questions