docs(wiki): discovery results, architecture, auth model, backend + relay pages

Ingests the 2026-07-09 live session (source page + raw GetConfiguration
dump): charger identified as SimpleCharge MultiSocketCharger, 60 kW DC
dual-standard (gun 1 EU/CCS, gun 2 GB/T); RFID and remote start/stop
verified; by-vehicle auth closed as not supported (three escalating tests
incl. MacEnabled=true after power-cycle); touchscreen-shows-VIN observation
with the DataTransferVendorId long-shot lead.

Adds/updates: architecture plan (FastAPI + PWA, phases 1-3 done), backend
entity, wifi-relays entity (Tuya local-control path + key extraction steps),
authorization concept (API user/scope model, per-gun cards), overview,
runbook, index, log.
This commit is contained in:
2026-07-11 18:58:20 +02:00
parent d7b17d9cb2
commit 3326c8d16c
12 changed files with 713 additions and 31 deletions
+13 -4
View File
@@ -6,7 +6,9 @@ tags: [hardware]
# Anfu Home Charger (charging pile)
The physical home EV charger this whole project revolves around. It is not a single device but a small network of three, behind its own Four-Faith router (see [[network-topology]]). Per [[2026-07-09-findings-and-requirements]]:
The physical home EV charger this whole project revolves around. Identity per the live probe ([[2026-07-09-discovery-eu092025]]): **SimpleCharge "MultiSocketCharger"**, serial `24310588`, firmware `1.24.0620.1`, OCPP ID **`eu092025`** — with **two guns** (connectors 1 and 2).
It is not a single device but a small network of three, behind its own Four-Faith router (see [[network-topology]]). Per [[2026-07-09-findings-and-requirements]]:
- **[[jc-6620|JC-6620]]** (`192.168.2.228`) — OCPP communication controller; the OCPP client that dials the CSMS
- **EV charging controller** (`192.168.2.118`, DHCP) — the main control board that actually manages charging; the JC-6620 talks to it on port 2403
@@ -25,8 +27,15 @@ The physical home EV charger this whole project revolves around. It is not a sin
> [!warning] Power-cycle required
> URL or network changes only take effect after power-cycling the pile.
## Capabilities in question
## Capabilities (per the live probe, [[2026-07-09-discovery-eu092025]], and the live charging test)
> [!warning] Superseded: "basic AC unit" (assumed in [[2026-07-09-findings-and-requirements]])
> The first live charging session (2026-07-09) showed gun 2 delivering **30.6 kW at 309.6 V / 98.8 A with SoC reporting** — that's **DC fast charging**, not AC. This is a DC-capable multi-standard charger.
- ✅ OCPP 1.6J over WebSocket — verified working
- ⚠️ Autocharge (per-vehicle idTag on plug-in) — needs a physical test; see [[authorization]]
- ❌ True ISO 15118 Plug & Charge — unlikely on a basic AC unit
- ✅ **DC fast charger, 60 kW** (owner-confirmed) with **two guns** — `NumberOfConnectors=2`: **gun 1 = EU standard (CCS), gun 2 = Chinese standard (GB/T)**; 30.6 kW observed on gun 2 while both guns charged simultaneously
- ⚠️ Telemetry quirk: while charging, gun 1's periodic samples read 0 W / 0 V (though SoC updated and energy was delivered — 349 Wh per Transaction.End); gun 2's samples looked sane. Watch whether gun 1 metering is lazy/lagged.
- ✅ Feature profiles: Core, **RemoteTrigger** (verified), **SmartCharging** (Power-based profiles, max 3 periods), Reservation, LocalAuthListManagement (max **6** entries), FirmwareManagement
- ✅ Meter data every 60 s while charging: Energy, Power, **SoC**, Voltage, Current
- ❌ Autocharge / vehicle ID over OCPP — **tested and closed 2026-07-09**: no idTag ever forwarded, even with `MacEnabled=true` after a power-cycle ([[authorization]]); the charger clearly holds the DC handshake (reports SoC) but firmware `1.24.0620.1` keeps the vehicle identity to itself
- ❌ True ISO 15118 Plug & Charge — nothing in the config suggests it