refactor(backend): single SQLite store — config.json eliminated

backend.db (renamed from sessions.db) now holds everything: the sessions
and samples tables plus a settings table with the app-state sections
(users, allowlist, relays, chargers, learn_mode, session_secret) as JSON
blobs. All mutations go through the API/panel and take effect immediately;
there is no config file and no hand-edit-then-restart ambiguity.

- legacy config.json auto-imports into the db on first start (renamed to
  config.json.migrated as a backup)
- new admin endpoints: PUT/DELETE /api/relays/{name} (how tinytuya wizard
  results are registered now) and PUT /api/chargers/{cp_id} (panel labels)
- BACKEND_DB env override so tests run on an isolated temp database
- smoke test: 45 checks, real db verified untouched
This commit is contained in:
2026-07-11 20:15:38 +02:00
parent 70c2fe1210
commit 56c9020d9f
10 changed files with 132 additions and 96 deletions
+1 -1
View File
@@ -19,7 +19,7 @@ Local control needs each device's **id + local key**, extracted once via Tuya's
1. Create a (free) account at `iot.tuya.com` → Cloud → create a project (data center matching the SmartLife account region).
2. Link the SmartLife app account to the project (Devices → Link App Account → scan QR in SmartLife).
3. From the repo root: `venv\Scripts\python -m tinytuya wizard` — enter the project's API id/secret; it dumps every paired device's `id`, `key`, `ip`, and protocol `version`.
4. Copy each relay into `backend/config.json` → `"relays"` (shape in `config.example.json`). The Tuya cloud account is never needed again unless a device is re-paired (**re-pairing regenerates the local key**).
4. Register each relay via `PUT /api/relays/<name>` (admin; interactive form at `/docs`) with its `id`, `key`, `ip`, `version`. The Tuya cloud account is never needed again unless a device is re-paired (**re-pairing regenerates the local key**).
Recommended: DHCP reservations for the relays and pinned `"ip"` entries in the config — `"ip": "auto"` works via UDP broadcast discovery but is slower and only finds relays on the same L2 segment as the backend host (❓ verify which subnet the relays are on vs. the future always-on host, see [[network-topology]]).