# Anfu Home Charger — OCPP Integration: Findings & Requirements _Last updated: 2026-07-09_ ## 1. Goal Run a **private, self-hosted OCPP 1.6J backend (CSMS)** for a home EV charger. No billing, no public charging. Authorization should be possible via: 1. **RFID cards** already owned (tap to charge). 2. **By vehicle / chassis**, if the hardware supports it (see §7 — has a caveat). 3. A **mobile / web app** (start/stop charging), hosted securely behind an existing **NetBird** private network. ## 2. Hardware & Topology The charging pile contains three networked devices behind its own router: ``` 10.0.10.0/24 (upstream / WAN — main gateway lives here) │ ┌──┴───────────────┐ │ Four-Faith router │ WAN gets a 10.0.10.x address; NAT boundary └──┬───────────────┘ │ LAN = 192.168.2.1 (mask 255.255.255.0) ├── 192.168.2.228 JC-6620 OCPP communication controller ← the OCPP client ├── 192.168.2.118 EV charging controller (main control board), DHCP └── 192.168.2.114 maintenance PC (LAN side) ``` - Wiring is the manufacturer's **star** topology: the EV charging controller **and** the JC-6620's fixed-IP (right) port each connect to a router LAN1–4 port. - **The JC-6620 (192.168.2.228) is the device that opens the outbound OCPP WebSocket** to the CSMS. It talks to the EV controller locally on port **2403**. ## 3. CSMS software (this repo) | File | Purpose | |------|---------| | `csms.py` | Minimal OCPP 1.6J server — accepts everything, logs raw frames. Discovery/tester. | | `rawlisten.py` | Dumb TCP listener on :9000 — shows whether *any* bytes arrive. Fallback diagnostic. | | `station.py` | **The real controller.** Allowlist-based auth + "learn mode" + hooks for remote start/stop. | | `station_config.json` | `{ "learn_mode": bool, "authorized": { "": {name, kind} } }` | | `seen_tags.json` | Auto-recorded log of every idTag observed (for discovery). | Runtime: Python venv with `websockets` (16.0) + `ocpp`. Server listens on `ws://0.0.0.0:9000/`. ## 4. Charger-side configuration (touchscreen) - **General Settings → Charger INEO:** `URL = ws://:9000`, `ChargerID = ` - **Back Office → Universal:** `Billing Mode = BackgroundBilling`, `Communication Method = Ethernet`, `JC-6620 IP = 192.168.2.228`, `Port = 2403` - **JC-6620 network config (静态 IP):** IP `192.168.2.228`, mask `255.255.255.0`, **default gateway (默认网关) `192.168.2.1`** (DNS not needed — CSMS is a bare IP). ## 5. Findings / gotchas (hard-won — check these first if it breaks) 1. **CSMS host firewall** must allow inbound **TCP 9000**. Windows silently drops otherwise → looks like "charger never connects." 2. **`Billing Mode` must be `BackgroundBilling`.** Until it is, the OCPP client never dials out *at all* (zero TCP SYNs). This was the blocker for the first connection. 3. **`Communication Method` must be `Ethernet`** (not 4G/SIM). 4. **URL / network changes require a pile power-cycle** to take effect. 5. **JC-6620 default gateway must be `192.168.2.1`.** It shipped as `192.168.2.228` (pointing at itself) — which reaches a *same-subnet* CSMS but **cannot route to the WAN**. This is why a `192.168.2.x` CSMS worked but a `10.0.10.x` CSMS did not, until the gateway was fixed. 6. **No port-forwarding needed on the charger router.** The JC-6620 is the *client* and dials outbound; NAT handles LAN→WAN. Port-forwarding would only matter for inbound. 7. **The CSMS host needs a stable IP.** The touchscreen URL is hardcoded, so the host must not change address (static IP or a DHCP reservation). ## 6. Verified working - ✅ **Local CSMS** at `192.168.2.114:9000` — JC-6620 connected, full BootNotification exchange. - ✅ **Remote / WAN CSMS** at `10.0.10.203:9000` (on the router's WAN subnet) — connected after fixing the JC-6620 default gateway. Confirms the CSMS can live upstream / off-subnet. ## 7. Requirements to build next All three authorization methods funnel through one gate in `station.py` — `decide(id_tag)` → Accepted/Rejected against the allowlist. So the build is: - **Allowlist enforcement** — already implemented. Learn mode captures ids; flip `learn_mode=false` to enforce. - **RFID cards** — tap each card once in learn mode, harvest its idTag from `seen_tags.json`, add to `authorized` with a name. Works with existing cards. - **By vehicle / chassis** — ⚠️ **needs a physical test.** True VIN / Plug & Charge (ISO 15118) is unlikely on a basic AC unit. The lighter option is **Autocharge**: some chargers auto-send a per-vehicle idTag on plug-in (no card). Test = plug car in without tapping; if a stable idTag appears in `seen_tags.json`, whitelist it as `kind:"car"`. If nothing appears, "by chassis" is not achievable on this hardware. - **Mobile / web app** — a web control panel (mobile-friendly, no app store) exposing Start/Stop via OCPP `RemoteStartTransaction` / `RemoteStopTransaction`, plus live status and clickable allowlist management. Bind to `0.0.0.0`, reach it over **NetBird**. Optional access token/PIN for defense-in-depth. ## 8. Open decisions (for you) - **Final host** for the always-on CSMS + app: the LAN PC, the `10.0.10.203` machine, or a dedicated always-on box (e.g. a Pi on the charger LAN joined to NetBird)? - **Web app auth:** rely on NetBird network isolation only, or also require a PIN/token? - **Autocharge:** do we run the plug-in test to see if "by chassis" is even possible? - **IP stability:** static IP vs DHCP reservation for the chosen host.