Files
charging_station/wiki/concepts/troubleshooting.md
T
julian 2e5960fae3 feat: bootstrap wiki for Anfu home EV charger OCPP integration project
- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md.
- Ingested findings and requirements document into the wiki.
- Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting.
- Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit.
- Established configuration files for Obsidian app settings and workspace layout.
- Implemented core plugins and appearance settings for the wiki.
2026-07-09 15:29:26 +02:00

1.4 KiB

type, updated, tags
type updated tags
concept 2026-07-09
troubleshooting
gotchas

Troubleshooting Checklist

Hard-won gotchas from getting the first connection working. If the charger "never connects," check these in order. Per 2026-07-09-findings-and-requirements:

  1. CSMS host firewall — inbound TCP 9000 must be allowed. Windows silently drops otherwise; looks identical to "charger never dials."
  2. Billing Mode must be BackgroundBilling — until it is, the jc-6620 never dials out at all (zero TCP SYNs on the wire). This was the blocker for the very first connection.
  3. Communication Method must be Ethernet — not 4G/SIM.
  4. Power-cycle after changes — URL / network changes on the anfu-charger only take effect after power-cycling the pile.
  5. JC-6620 default gateway must be 192.168.2.1 — it shipped as 192.168.2.228 (itself). Symptom: a same-subnet (192.168.2.x) CSMS works but an off-subnet (10.0.10.x) one silently doesn't.
  6. No port-forwarding needed — the JC-6620 is the client and dials outbound; see network-topology. Don't waste time on the router's forwarding rules.
  7. CSMS host IP must be stable — the touchscreen URL is hardcoded; a DHCP-shifted host looks like a dead CSMS.

Diagnostic ladder (from csms-toolkit): rawlisten.py (do any bytes arrive?) → csms.py (does OCPP handshake complete?) → station.py (full controller).