- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md. - Ingested findings and requirements document into the wiki. - Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting. - Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit. - Established configuration files for Obsidian app settings and workspace layout. - Implemented core plugins and appearance settings for the wiki.
1.6 KiB
type, updated, tags
| type | updated | tags | ||
|---|---|---|---|---|
| entity | 2026-07-09 |
|
JC-6620 — OCPP Communication Controller
The dedicated OCPP communication controller inside the anfu-charger. This is the device that acts as the OCPP client — it opens the outbound WebSocket to the CSMS. (Per 2026-07-09-findings-and-requirements.)
Network identity
- Static IP
192.168.2.228, mask255.255.255.0, on the charger's internal LAN (see network-topology) - Default gateway must be
192.168.2.1(the Four-Faith router) - DNS not needed — the CSMS URL is a bare IP
- Talks to the EV charging controller (
192.168.2.118) locally on port 2403
Gotchas specific to this device
[!warning] Shipped misconfigured The JC-6620 arrived with its default gateway set to
192.168.2.228— pointing at itself. That works for a same-subnet CSMS but cannot route to the WAN, which is why a192.168.2.xCSMS worked while a10.0.10.xCSMS silently didn't, until the gateway was corrected. (Config screen is in Chinese: 静态 IP = static IP, 默认网关 = default gateway.)
- It only dials out at all once the touchscreen's
Billing Mode = BackgroundBillingis set — see troubleshooting. - Network/URL changes require a full pile power-cycle to take effect.
Verified behavior ✅
Connected and completed the full BootNotification exchange against both a LAN CSMS (192.168.2.114:9000) and a WAN CSMS (10.0.10.203:9000). Since it's the client, no port-forwarding is needed on the charger router — NAT handles the outbound connection.