2e5960fae3
- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md. - Ingested findings and requirements document into the wiki. - Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting. - Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit. - Established configuration files for Obsidian app settings and workspace layout. - Implemented core plugins and appearance settings for the wiki.
2.3 KiB
2.3 KiB
type, updated, ingested, raw, tags
| type | updated | ingested | raw | tags | |||
|---|---|---|---|---|---|---|---|
| source | 2026-07-09 | 2026-07-09 | raw/FINDINGS_AND_REQUIREMENTS.md |
|
Findings & Requirements — Anfu Home Charger OCPP Integration
Raw source: FINDINGS_AND_REQUIREMENTS.md (project findings doc, last updated 2026-07-09)
TL;DR
The goal is a private, self-hosted OCPP 1.6J CSMS for a home EV charger — no billing, no public charging. Authorization via existing RFID cards, possibly by vehicle (Autocharge, ⚠️ untested), and a web app reached over netbird. Connectivity is ✅ solved: the jc-6620 controller inside the anfu-charger successfully dials out to a CSMS both on the local LAN and across the NAT boundary on the WAN subnet, after several hard-won configuration fixes.
Key facts
- Hardware topology — three devices behind a Four-Faith router (LAN
192.168.2.0/24, WAN on10.0.10.0/24): the JC-6620 OCPP controller (.228), the EV charging controller (.118), and a maintenance PC (.114). Details in network-topology. - The JC-6620 is the OCPP client. It opens the outbound WebSocket to the CSMS and talks to the EV controller locally on port 2403.
- CSMS software is the scripts in
../discovering/— see csms-toolkit.station.pyis the real controller with allowlist auth + learn mode. - Charger-side config happens on the pile's touchscreen: CSMS URL, ChargerID,
Billing Mode = BackgroundBilling,Communication Method = Ethernet, JC-6620 static IP with gateway192.168.2.1. - Gotchas (each cost real debugging time) are catalogued in troubleshooting — notably: no
BackgroundBilling= zero TCP SYNs, and the JC-6620 shipped with its gateway pointing at itself. - Verified working: ✅ local CSMS at
192.168.2.114:9000; ✅ WAN CSMS at10.0.10.203:9000after the gateway fix. - Next build: the three authorization methods, all funneling through
decide(id_tag)instation.py. - Open decisions (host choice, web-app auth, Autocharge test, IP stability) tracked in overview.
Wiki changes from this ingest
First source — seeded the entire wiki: overview, jc-6620, anfu-charger, csms-toolkit, network-topology, authorization, troubleshooting, ocpp, netbird.