- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md. - Ingested findings and requirements document into the wiki. - Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting. - Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit. - Established configuration files for Obsidian app settings and workspace layout. - Implemented core plugins and appearance settings for the wiki.
1.4 KiB
1.4 KiB
type, updated, tags
| type | updated | tags | ||
|---|---|---|---|---|
| concept | 2026-07-09 |
|
Troubleshooting Checklist
Hard-won gotchas from getting the first connection working. If the charger "never connects," check these in order. Per 2026-07-09-findings-and-requirements:
- CSMS host firewall — inbound TCP 9000 must be allowed. Windows silently drops otherwise; looks identical to "charger never dials."
Billing Modemust beBackgroundBilling— until it is, the jc-6620 never dials out at all (zero TCP SYNs on the wire). This was the blocker for the very first connection.Communication Methodmust beEthernet— not 4G/SIM.- Power-cycle after changes — URL / network changes on the anfu-charger only take effect after power-cycling the pile.
- JC-6620 default gateway must be
192.168.2.1— it shipped as192.168.2.228(itself). Symptom: a same-subnet (192.168.2.x) CSMS works but an off-subnet (10.0.10.x) one silently doesn't. - No port-forwarding needed — the JC-6620 is the client and dials outbound; see network-topology. Don't waste time on the router's forwarding rules.
- CSMS host IP must be stable — the touchscreen URL is hardcoded; a DHCP-shifted host looks like a dead CSMS.
Diagnostic ladder (from csms-toolkit): rawlisten.py (do any bytes arrive?) → csms.py (does OCPP handshake complete?) → station.py (full controller).