feat(review): sample every detected car, not only ticketed entries
Build & push images / images (push) Successful in 5m20s
Build & push images / images (push) Successful in 5m20s
The entry stream for the reviewer was fed from the session-tied read only (ticket printed / exit signed). park-2 ran an afternoon with its barriers up: hundreds of camera vehicle pushes, zero tickets, zero samples. - anpr-entry: keep the best-framed vehicle of each poll loop (highest body-type confidence with a box), store that frame as a snapshot (identity pass:<id>, no session) and emit a vehicle read with the camera id — plate or no plate. One sample per detection, fire-and-forget, never on the ANPR path. - snapshot.ts: normalizedBoxes() shared by the session-tied read and the bridge; vehicle reads now carry deviceId. - review-outbox: sampleEntry(deviceId) dedups per camera for 30 s so the pass sample and a ticket entry's read (same car, seconds apart) go once. - wiki: outbox page (entry stream, troubleshooting checklist for 'nothing arrives': the month-long silence was a missing Netbird policy, not code), park-2 camera port-forward procedure (site-device-installation §7), log.
This commit is contained in:
@@ -285,6 +285,49 @@ barcode with a real ticket (the KP-300H garbled overflowing barcodes until the g
|
||||
8. Record in the site record: every IP, serial, camera password, printer model, which relay is
|
||||
which, photos of the labels. Remove the temporary laptop addresses. Log out of every device UI.
|
||||
|
||||
## 7. Reaching the cameras remotely — port forward through the booth host (park-2, 2026-10-08)
|
||||
|
||||
park-buzi exposed its two Hikvision web UIs on the site router (`park-buzi.msai.al:8081` / `:8082`,
|
||||
see [[lpr-camera]]). park-2 does the same **through the booth host**, because its router only
|
||||
knows the 192.168.1.0/24 side while the cameras live on the device VLAN:
|
||||
|
||||
| | address |
|
||||
| --- | --- |
|
||||
| router / internet side | `eno1` 192.168.1.101, gateway 192.168.1.1, public 91.230.255.154 |
|
||||
| device VLAN side | `eno1` 10.0.10.101 (same NIC, second address) |
|
||||
| Netbird | `wt0` 100.75.7.237 = `park-2.nb.infra` |
|
||||
| entry camera | 10.0.10.9:80 → published as **8081** |
|
||||
| exit camera | 10.0.10.10:80 → published as **8082** |
|
||||
|
||||
Done with iptables on the host (needs root; the admin account has no passwordless sudo).
|
||||
`ip_forward` is already 1 because Docker set it. Docker also sets the FORWARD policy to DROP, so
|
||||
the explicit ACCEPTs are mandatory, and the SNAT is what brings the camera's replies back through
|
||||
the host (the cameras' gateway is not the booth):
|
||||
|
||||
```bash
|
||||
iptables -t nat -A PREROUTING -p tcp --dport 8081 -j DNAT --to-destination 10.0.10.9:80
|
||||
iptables -t nat -A PREROUTING -p tcp --dport 8082 -j DNAT --to-destination 10.0.10.10:80
|
||||
iptables -t nat -A POSTROUTING -p tcp -d 10.0.10.9 --dport 80 -j SNAT --to-source 10.0.10.101
|
||||
iptables -t nat -A POSTROUTING -p tcp -d 10.0.10.10 --dport 80 -j SNAT --to-source 10.0.10.101
|
||||
iptables -I FORWARD -p tcp -d 10.0.10.9 --dport 80 -j ACCEPT
|
||||
iptables -I FORWARD -p tcp -d 10.0.10.10 --dport 80 -j ACCEPT
|
||||
iptables -I FORWARD -m conntrack --ctstate ESTABLISHED,RELATED -j ACCEPT
|
||||
apt install -y iptables-persistent && netfilter-persistent save # survive reboots
|
||||
```
|
||||
|
||||
- **Reach:** from any Netbird peer with a policy to park-2, `http://park-2.nb.infra:8081/`
|
||||
(no router change needed). From the internet only once the router forwards 8081/8082 to
|
||||
192.168.1.101. PREROUTING does not apply to the host's own traffic — test from another machine.
|
||||
- **Netbird-only variant:** add `-d 100.75.7.237` to the two PREROUTING rules; then the public
|
||||
forward can never reach the cameras even if someone adds it on the router.
|
||||
- **Undo:** the same lines with `-D`. **ufw**, if ever enabled there, also needs
|
||||
`ufw route allow proto tcp to 10.0.10.9 port 80` (and `.10`).
|
||||
- **Why not Docker:** `docker run -p 100.75.7.237:8081:80 alpine/socat …` would do the same
|
||||
without sudo, bound to the overlay only; the user chose the iptables route.
|
||||
- This is a deliberate hole in [[network-isolation]] (camera web UI reachable off the VLAN);
|
||||
the camera's own digest auth is the only gate behind it. Keep the public side off unless
|
||||
needed; prefer the Netbird path.
|
||||
|
||||
## Gaps to fill next time you hold the hardware
|
||||
|
||||
- Factory address and configuration tool of the **Cashino KP-300H** and the **Rongta RP** units
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
---
|
||||
title: Vision review outbox — harvesting the operator's category choice for a trusted reviewer
|
||||
type: concept
|
||||
status: booth side built 2026-09-06; collector pending
|
||||
status: live — first package delivered park-2 → collector 2026-10-08 (after a month blocked by a missing Netbird policy)
|
||||
related: [venue-modules, opencv-anpr-service, threat-model, append-only-event-chain, network-isolation]
|
||||
---
|
||||
|
||||
@@ -58,6 +58,20 @@ exactly one in N) and calls `enqueueEntry()`; the core never imports the module.
|
||||
as "entry stream — label the vehicle", the export carries a `kind` column, and **operator
|
||||
agreement is computed from wash items only** (an entry sample has no operator decision).
|
||||
|
||||
**Every car that passes, not only ticketed ones (2026-10-08).** The entry stream was fed from
|
||||
the session-tied read only (`snapshot.ts`, taken when a ticket is printed or an exit is signed).
|
||||
park-2 ran a whole afternoon with its barriers up: hundreds of camera vehicle pushes, zero
|
||||
tickets, zero samples. So the ANPR bridge (`anpr-entry.ts`), which already pulls and analyses
|
||||
frames for every vehicle push on an `anpr: true` camera, now keeps the **best-framed vehicle of
|
||||
each poll loop** (highest body-type confidence with a box), stores that one frame as a snapshot
|
||||
(`identity = pass:<snapshotId>`, no session) and emits a vehicle read with the camera's id —
|
||||
plate or no plate. One sample per detection (the loop is one per car, joins slide it). The
|
||||
module's `sampleEntry(deviceId)` **dedups per camera for 30 s** (`ENTRY_DEDUP_MS`): the pass
|
||||
sample and the ticket entry's read, seconds apart from the same camera, are one car. The plate
|
||||
box is handed over whenever the detector saw a plate, confident or not — it is what the crop
|
||||
blurs. Pass snapshots ride the normal retention/pruning. Needs `anpr: true` and the per-camera
|
||||
auto-trigger on (the bridge bails before polling otherwise) — same gate as recognition today.
|
||||
|
||||
An internet feed was considered the same day and kept OUT of the collector's ingest: licensed
|
||||
sets only, in a separate folder with provenance, used as warm-up and weighted down, and never
|
||||
the judge of accuracy — the evaluation set is gate crops only.
|
||||
@@ -177,3 +191,32 @@ that start like a spreadsheet formula (category/service names are booth-supplied
|
||||
**Status (2026-09-07).** Live: the collector runs on `art-docker-station` and park-2 is wired to
|
||||
it (`stage-dbbb051` on both stacks, every entry sampled). The review screen at
|
||||
`http://docker-station.nb.infra:8090/review` is filling; no labels reviewed yet.
|
||||
|
||||
## Troubleshooting — "the cameras are busy but nothing reaches the collector" (2026-10-08)
|
||||
|
||||
Found a month after both sides were built: **not one package had ever arrived**. Both codebases
|
||||
were fine; the Netbird **policy** between the booths group and the collector host did not exist,
|
||||
so `docker-station.nb.infra` resolved nowhere from the booth (Node: `fetch failed`, cause
|
||||
`ENOTFOUND`; every row `queued`, attempts climbing, the 6 h backoff cap hiding it). Adding the
|
||||
policy in the Netbird dashboard was the whole fix — the first row went out at its next scheduled
|
||||
retry, nothing restarted. Checklist, in order:
|
||||
|
||||
1. **Is anything queued at all?** Only a vehicle read **tied to a session** (ticket taken or an
|
||||
exit) is sampled; the camera's motion pushes feed subscription plate matching only. Barriers
|
||||
left open = no tickets = no samples, however busy the lane. Query on the booth (no sqlite3
|
||||
there; use the image's own driver):
|
||||
```bash
|
||||
s=$(docker ps -q --filter name=server); m=/app/node_modules/.pnpm/better-sqlite3@12.10.1/node_modules/better-sqlite3
|
||||
docker exec $s node -e "const D=require('$m');const db=new D('/data/parking.sqlite',{readonly:true});
|
||||
console.log(db.prepare(\"select status, json_extract(payload,'\$.kind') kind, count(*) n, max(sent_at) lastSent, max(last_error) err from carwash_review_outbox group by 1,2\").all())"
|
||||
```
|
||||
(`kind` lives inside `payload`; the image is in the row until delivered.)
|
||||
2. **`fetch failed`** → from the booth host: `resolvectl query docker-station.nb.infra` and
|
||||
`netbird status -d | grep -A4 docker-station`. Not found / not listed = the booth and the
|
||||
collector host are not peers → Netbird policy. Resolves = `curl -X POST
|
||||
http://docker-station.nb.infra:8090/ingest` must answer **401** (the collector's token check),
|
||||
anything else is the collector.
|
||||
3. **Collector side:** `docker logs wash-collector-collector-1 | grep -c /ingest` — zero means
|
||||
nothing ever arrived; the container's health lines are its own probes.
|
||||
4. After the fix, rows drain on **their own timers** (`1 min · 2^attempts`, cap 6 h); a restart
|
||||
does not reset `next_attempt_at`. Expect a backlog to trickle in over hours, new rows at once.
|
||||
|
||||
Reference in New Issue
Block a user