fix(devices): Dahua snapshot channel is 1-based; add Dahua clock sync; wiki page for the bench IPC-HFW2549T
Build & push images / images (push) Successful in 3m25s

The dahua driver decremented the wizard's channel on the belief the CGI is
0-based. On real hardware (IPC-HFW2549T-AS-IL, fw V2.880, 2026-09-17)
snapshot.cgi?channel=0 answers HTTP 400 and channel=1 returns the 2880x1620
JPEG — so every Dahua assignment sat at degraded "HTTP 400". The channel is
now sent as entered (clamped >= 1) and the URL is pinned in camera.test.ts.

DahuaCamera.syncClock reads global.cgi getCurrentTime and, past the drift
limit, writes setCurrentTime with the host's naive local wall time (no offset):
the OSD burned into snapshots must match the booth clock; the camera's tz/DST
config is left alone. Verified live: a 2h-off set, set back, 1s drift -> no
write. The device monitor picks it up via isClockSyncable unchanged.

Wiki: new entities/dahua-ipc-hfw2549t.md (endpoint table, verbatim
eventManager attach parts — VideoMotion Start/Stop, VideoMotionInfo,
TimeChange — RealUTC is the camera's belief of UTC, 5-strike login lockout,
unit not factory-fresh); lpr-camera Dahua bullet corrected; runbook §3 Dahua
paragraph; index + log. The server-side attach-stream subscriber is not built.
This commit is contained in:
2026-10-08 08:03:50 +02:00
parent 4d1d245680
commit 4593a397dd
7 changed files with 348 additions and 16 deletions
+1
View File
@@ -45,6 +45,7 @@ Counts: 4 sources · 19 entities · 47 concepts · 8 decision records.
- [[dingtian-dt008-reader]] — Dingtian DT-008 QR/RFID reader on hand; HTTP-GET push, server replies the verdict; ⚠️ our two units read disjoint card sets (125 kHz vs 13.56 MHz) — unresolved, see open question #18.
- [[zkteco-controller]] — ❌ rejected/historical; aux-input path was a contender, not pursued.
- [[dingtian-relay]] — ✅ CHOSEN access controller; decoupled inputs solve the button blocker (driver verified on hardware); spare relays drive aux outputs (`setAux`).
- [[dahua-ipc-hfw2549t]] — first Dahua on the bench (IPC-HFW2549T-AS-IL, fw 2.880, 2026-09-17): the driver's channel decrement gave HTTP 400 (channels are 1-based — fixed + verified live); Dahua clock-sync built (`global.cgi`, naive wall time); events = held `eventManager attach` multipart stream, verbatim `VideoMotion Start/Stop` + `TimeChange` parts captured, subscriber not built; `RealUTC` is the camera's belief of UTC; 5-strike login lockout.
- [[hikvision-radar]] — vehicle-presence radar on a Dingtian input; the entry presence gate (per-input active-level caveat).
- [[rongta-printer]] — ✅ CHOSEN 80mm thermal printer; ESC/POS over raw TCP 9100 (or local USB, see [[printer-usb-transport]]); driver written, one unit reachable at 10.0.10.6.
- [[k200l-printer]] — the park-buzi printer identified (2026-09-09): Xprinter/ICS K200L, USB id 1fc9:2016 "POS-80", J-Speed LAN board at 192.168.123.100 (DHCP off, web config on :80); status page `/prt_status.htm` (Rongta's rows, headerless HTTP) → own `k200l` driver with raw-socket fetch; over USB reachability only, so cover-open never showed at park-buzi.