docs(wiki): site device installation — the field runbook for what to know before the booth
Build & push images / images (push) Successful in 2m50s
Build & push images / images (push) Successful in 2m50s
Per device (Dingtian relay board, DT-008 readers, Hikvision G3H camera, radar, K200L / Rongta / Cashino printers): factory address and login, the tool needed, what the wizard configures by itself on assign vs what is done by hand on the device, how to verify, and the traps already paid for (unauthenticated Dingtian CGI + session_en brick, duplicate reader IP, reader settings lost on reset, sub stream mandatory, Alarm Server after assign + Vehicle target filter, close the camera web UI, radar idle level, "Test" only probes a printer). Bring list, the 10.0.10.x address plan beside each factory address, the on-site order of work, and the gaps still unrecorded. Linked from appliance-provisioning and the K200L page; log entries for the day. Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
This commit is contained in:
@@ -14,6 +14,8 @@ parking appliance. Written from the **first real provisioning, 2026-06-23** (har
|
||||
actual hardware, including the firmware-specific workaround. Companion to [[disk-os-hardening]] (the
|
||||
*why*), [[tpm]] (TPM analysis), [[container-deployment]] (the images), and
|
||||
[[fleet-deployment-komodo]] (the deploy control plane this runbook's §7 uses).
|
||||
**The devices plugged into the booth** (relay board, readers, cameras, radar, printers — factory
|
||||
addresses, tools, hand steps, traps) have their own field runbook: [[site-device-installation]].
|
||||
|
||||
> ⚠ This box is the [[threat-model|outsider-with-the-box]] defence. The load-bearing anti-fraud
|
||||
> control is still [[reconciliation]] over the [[append-only-event-chain|signed chain]] — disk
|
||||
|
||||
Reference in New Issue
Block a user