From 4d1d245680ca93d76829298cf9e42521a4bdfaf8 Mon Sep 17 00:00:00 2001 From: Julian Cuni Date: Thu, 17 Sep 2026 09:47:40 +0200 Subject: [PATCH] docs(wiki): DT-008 card-technology findings, box leaflet source, install checklist; add scripts/reader-sink.py MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only) although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as unresolved with the EM4100 test that settles it (open question #18). Phone taps give a random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink answering the push with the SDK verdict and Connection: close. Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU --- scripts/reader-sink.py | 79 +++++++++++++++++++++ wiki/concepts/site-device-installation.md | 48 ++++++++++++- wiki/decisions/open-questions.md | 14 ++++ wiki/entities/dingtian-dt008-reader.md | 83 ++++++++++++++++++++++- wiki/index.md | 3 +- wiki/log.md | 29 ++++++++ wiki/sources/dingtian-dt008-box-manual.md | 39 +++++++++++ 7 files changed, 290 insertions(+), 5 deletions(-) create mode 100755 scripts/reader-sink.py create mode 100644 wiki/sources/dingtian-dt008-box-manual.md diff --git a/scripts/reader-sink.py b/scripts/reader-sink.py new file mode 100755 index 0000000..fae6a70 --- /dev/null +++ b/scripts/reader-sink.py @@ -0,0 +1,79 @@ +#!/usr/bin/env python3 +"""Bench sink for the Dingtian DT-008 QR/RFID reader. + +Answers the reader's HTTP-GET push on any path (/qa/mcardsea.php|jsp|asp|aspx|cgi) with the +vendor-SDK verdict JSON and `Connection: close`, and prints one line per read. Stdlib only. + + python3 scripts/reader-sink.py # port 80 (needs sudo/admin), refuse = 1 beep + python3 scripts/reader-sink.py -p 3000 --accept # accept = 2 beeps, output 0 + +Point the reader's Server address/port at this machine (QRCode tool → Setting → Network parameter). +See wiki/entities/dingtian-dt008-reader.md. +""" +import argparse +import json +import time +from http.server import BaseHTTPRequestHandler, HTTPServer +from urllib.parse import parse_qs, urlsplit + +ACCEPT = False + + +class Sink(BaseHTTPRequestHandler): + protocol_version = "HTTP/1.0" + + def log_message(self, *_): # silence the default access log; we print our own line + pass + + def _handle(self): + q = {k: v[0] for k, v in parse_qs(urlsplit(self.path).query).items()} + cardid = q.get("cardid", "") + status = q.get("status", "") + channel = "qr" if cardid.startswith("Q:") else "card" if cardid.startswith("K:") else "?" + print( + f"{time.strftime('%H:%M:%S')} {self.client_address[0]:15} serial={q.get('cjihao', '?'):10} " + f"dev={q.get('mjihao', '?'):3} dir={'in' if status[-1:] == '1' else 'out' if status[-1:] == '0' else '?':3} " + f"ch={channel:4} cardid={cardid!r} path={urlsplit(self.path).path}", + flush=True, + ) + body = json.dumps( + { + "data": [ + { + "cardid": cardid, + "cjihao": q.get("cjihao", ""), + "mjihao": q.get("mjihao", ""), + "status": 1 if ACCEPT else 0, # 1 = valid (2 beeps), 0 = invalid (1 beep) + "time": str(int(time.time())), + "output": 0, + } + ], + "code": 0, + "message": "", + } + ).encode() + self.send_response(200) + self.send_header("Content-Type", "application/json") + self.send_header("Content-Length", str(len(body))) + self.send_header("Connection", "close") # the reader only acts once the socket closes + self.end_headers() + self.wfile.write(body) + + do_GET = _handle + do_POST = _handle + + +def main(): + global ACCEPT + ap = argparse.ArgumentParser(description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter) + ap.add_argument("-p", "--port", type=int, default=80) + ap.add_argument("-b", "--bind", default="0.0.0.0") + ap.add_argument("--accept", action="store_true", help="reply status=1 (valid, 2 beeps) instead of 0") + a = ap.parse_args() + ACCEPT = a.accept + print(f"reader sink on {a.bind}:{a.port} verdict={'ACCEPT' if ACCEPT else 'REFUSE'} (Ctrl-C to stop)", flush=True) + HTTPServer((a.bind, a.port), Sink).serve_forever() + + +if __name__ == "__main__": + main() diff --git a/wiki/concepts/site-device-installation.md b/wiki/concepts/site-device-installation.md index 8df8829..5b82830 100644 --- a/wiki/concepts/site-device-installation.md +++ b/wiki/concepts/site-device-installation.md @@ -112,6 +112,49 @@ and only after the server's reply (no reply = no beep, the scan still happened). **Trap:** a factory reset or a swapped unit silently loses items 3–5. Re-apply all of them. +**Trap (2026-09-17): two DT-008 units read disjoint card sets.** park-buzi's units (`H05M…`) +read the site's 125 kHz cards and the fresh lab unit (`HC002721`) reads only 13.56 MHz cards, +although the box leaflet claims both. Batch variant, a dead 125 kHz front end, or a non-EM 125 kHz +card format — unresolved. Rule until it is: **test a replacement reader against the site's actual +cards before it ships**, and record the site's card technology. Quick sort of a card: an NFC phone +detects 13.56 MHz, cannot see 125 kHz. Details: [[dingtian-dt008-reader]] §"Two units, two card +sets". + +**Identify what a reader can read — before it ships (2026-09-17).** Keep a **reference kit** in the +lab: one known EM4100 125 kHz fob, one known Mifare Classic (M1) card, and a phone with NFC. Tap all +three on the unit with the tool's log pane open (or [[dingtian-dt008-reader]] §Bench sink): a line +per tap = that technology decodes. The phone always beeps on a 13.56 MHz unit with a random `08…` +id (never a credential, but proves the 13.56 MHz radio). Then tap **the site's own cards**. Write +the result on the site record next to the serial (`reads: EM4100 | M1 | both`). Serial families are +only a hint (`H05M…` read park-buzi's 125 kHz cards, `HC…` did not); the vendor can confirm from a +serial. A unit that fails the site's cards does not leave the lab. + +**Parameters per card technology** — identical except one field: + +| | 125 kHz site (park-buzi today) | 13.56 MHz site | +| --- | --- | --- | +| Card Input format | **`6H`** (what park-buzi's cards are enrolled with — never change on a live site) | **`8H`** preferred: the native UID is 4 bytes, `6H` drops one and two cards can collide — confirm `8H` on the lab unit before the first enrolment ([[open-questions]] #18) | +| Output prefixes | `Q:` / `K:` | `Q:` / `K:` | +| Output type / server | HTTP, booth IP, booth HTTP port | same | +| Buzzer | On (the operator hears accept/refuse) | On | +| Symbologies | QR + Code128 only | same | +| Card stock | EM4100 (or whatever the reference test showed) — do not mix | Mifare Classic UID-based; note that a phone is never a card | + +A site is one technology: once cards are enrolled the reader batch, the input format and the +card stock are frozen together. Migrating means re-enrolling every credential. + +**The tool's Setting tab (v1.6.5, seen 2026-09-17):** *Search device* lists units by serial; *Get +parameter* loads one. *Network parameter*: IP / Netmask / Gateway / DNS1 / DNS2, DHCP (Static IP), +**Server address / Server Port / HTTP Server Language**, its own *Set* button. *Format parameter*: +Output type `HTTP`, **Card Input format** (`6H`), QRCode Output format/prefix/suffix, **Card Output +format/prefix/suffix** (prefix fields are where `Q:` / `K:` go), serial baud/bits greyed out under +HTTP, Low/High Pulse, its own *Set*. *External parameter*: Restart interval (12 h), Work mode +(Normal), **Buzzer On/Off**, Scan code fill light, its own *Set*. Each group is written by **its own +Set button** — setting the network and forgetting the format *Set* is easy. The log pane at the bottom +echoes every card read by the tool (`… A238BC`), which is the quickest "did the radio see it" check. +The *Test device* tab is the read monitor. Symbology selection was not found on this tab — locate it +on the *Test device* tab or in a newer tool before relying on item 5. + ## 3. Hikvision camera (DS-2CD1047G3H-LIU, AcuSense) — ANPR + snapshots **Factory:** `192.168.1.64`, **inactive** until a password is set on first boot (browser at that @@ -197,7 +240,10 @@ barcode with a real ticket (the KP-300H garbled overflowing barcodes until the g - Factory address and configuration tool of the **Cashino KP-300H** and the **Rongta RP** units (both still unknown here). -- The exact screens in `QRCode_v1_6_5.exe` for the reader's IP and server target (a screenshot). +- Where in `QRCode_v1_6_5.exe` the **symbologies** are selected (the Setting tab has no such field; + the IP / server / prefix fields are now described in §2). +- The **card technology** each site uses and which reader batch reads it, on the site record next to + the serial; and the result of the EM4100 test on the lab unit. - Whether the camera activation was done with SADP or the browser at park-buzi, and the per-site camera password location. - Where the **site record** lives (a page per site under `wiki/entities/`? — park-buzi and park-2 diff --git a/wiki/decisions/open-questions.md b/wiki/decisions/open-questions.md index bbd4bd9..b999087 100644 --- a/wiki/decisions/open-questions.md +++ b/wiki/decisions/open-questions.md @@ -156,3 +156,17 @@ procurement. (See [[parking-system-architecture]] §10.) Interacts with #9 (a statement is **not** a fiscal invoice; fiscalisation is off-appliance) and #8 (one currency per party until FX exists). Also reopened on the subscription page: a **renewal is currently off-book** (an edit, no `payment`). + +18. **DT-008 — why two units read disjoint card sets, and `6H` on a 13.56 MHz UID.** _(Raised on + the bench, 2026-09-17.)_ park-buzi's readers (`H05M…`) read the site's 125 kHz cards; the fresh + lab unit (`HC002721`) reads only 13.56 MHz cards, although the box leaflet claims EM-ID + M1 + + 14443A/B + 15693 in one unit. Unresolved between a batch variant, a dead/disabled 125 kHz front + end, and a non-EM 125 kHz card format at park-buzi. To settle: (a) a known EM4100 fob on the lab + unit (reads → card format; not → unit/variant, vendor with the serial); (b) the site record + names the card technology and a replacement is tested against real cards before shipping; + (c) on a 13.56 MHz read the native UID is 4 or 7 bytes, so + **`Card Input format = 6H` truncates it** — a phone tap showed it keeps the first three bytes in + reversed order and drops the fourth; confirm on a card with a printed UID, and decide whether + `8H` is required for 13.56 MHz sites before any card is enrolled against one. (Phones present a + random `08…` UID per tap and can never be credentials.) See + [[dingtian-dt008-reader]] §"Two RF variants". diff --git a/wiki/entities/dingtian-dt008-reader.md b/wiki/entities/dingtian-dt008-reader.md index b82bfa8..084a58e 100644 --- a/wiki/entities/dingtian-dt008-reader.md +++ b/wiki/entities/dingtian-dt008-reader.md @@ -2,7 +2,7 @@ type: entity tags: [parking, hardware, readers, qr, dingtian] sources: [dingtian-dt008] -updated: 2026-07-04 +updated: 2026-09-17 status: open --- @@ -25,8 +25,9 @@ or RFID [[subscription]]** credentials. Product page: dingtian-tech.com/en_us/qr - **QR/barcode + card.** Reads **QR / simple barcode** AND **ID/IC/NFC cards** (~0.2 s, 0–10 cm). (An earlier note guessed "ER80-EM = 125 kHz EM4100 prox" — that was part of the same mis-id.) -- **Interfaces: Wiegand 26/34, TCP/IP, USB, RS485.** (NOT RS-232 — that was a fictional-datasheet - claim.) For our integration it talks **HTTP over TCP/IP**; Wiegand is the reader's *output line* +- **Interfaces: Wiegand 26/34, TCP/IP, USB, RS485** per the product page; the box leaflet + ([[dingtian-dt008-box-manual]]) also lists **RS232**. (An earlier note dismissed RS-232 as a + claim from the mis-identified GEE PDF — withdrawn 2026-09-17.) For our integration it talks **HTTP over TCP/IP**; Wiegand is the reader's *output line* on a valid read, not the host transport. - **Power** 9–16 V DC, 800 mA; **86×86×42 mm**; −30…70 °C. Fits the [[disk-os-hardening|appliance]]. @@ -182,6 +183,82 @@ symbology except **QR + Code128** (all our credentials); if offered, set **minim re-enables the phantom symbologies — re-apply after any reset/replacement. Physical fallback if any noise survives: hood/visor the window, tilt it down, avoid facing the striped arm. +## ⚠️ Two units, two card sets, no overlap — 125 kHz vs 13.56 MHz (2026-09-17, unresolved) + +The product page says the DT-008 reads "ID/IC/NFC cards" and the **box leaflet** +([[dingtian-dt008-box-manual]]) claims EM-ID, M1, ISO 14443A/B and ISO 15693 in one unit. Yet on +the bench 2026-09-17, with two card sets, the two units we own read **disjoint** sets: + +| Unit | Serial family | Reads | Does not read | +| --- | --- | --- | --- | +| park-buzi entry/exit (bought 2026-06) | `H05M…` (`H05M2AFA`, `H05MA5B0`) | the site's enrolled cards (**125 kHz "ID"**, EM4100-class) | 13.56 MHz cards | +| lab unit (fresh, 2026-09) | `HC002721` | **13.56 MHz "IC/NFC"** cards (e.g. UID `A238BC`) | the park-buzi card set | + +**The decisive test needs no hardware:** hold each card on an NFC-capable phone. A 13.56 MHz card +is detected; a **125 kHz card is invisible to a phone**. The lab reader and the phone agreed on +exactly the same set, and the other set was invisible to both — so the park-buzi set is 125 kHz and +the park-buzi readers are the 125 kHz variant. Card bodies help too: EM4100 / TK4100 / T5577 (often +a printed 10-digit decimal) = 125 kHz; Mifare / S50 / 1K / NTAG = 13.56 MHz. + +Nothing in `QRCode_v1_6_5.exe` selects the frequency (no card-type field — see the screenshot in +[[site-device-installation]] §2). + +**Why the lab unit does not read them is NOT settled** — the phone test only proves the park-buzi +cards are *not* 13.56 MHz. Three explanations remain, with different fixes: + +1. **The park-buzi cards are 125 kHz but not EM4100** (HID Prox / Indala / AWID / a T5577 in a + non-EM format): invisible to a phone, not decoded by an EM-only front end, but read by the older + batch. Card bodies help: EM cards usually print a 10-digit decimal; HID cards carry the HID logo. +2. **The lab unit's 125 kHz front end is dead or disabled** — the leaflet says it should be there; + a firmware setting the v1.6.5 tool does not expose is possible. +3. **The leaflet is generic and units ship per variant** — the vendor can say from the two serials. + +**Decisive test (cheap):** a known **EM4100 125 kHz card/keyfob** on the lab unit, held at 1–10 cm. +Reads → its 125 kHz radio works and the park-buzi cards are a different 125 kHz format (→ 1). +Does not read → unit defect or variant (→ 2/3, vendor with the serial). A USB keyboard-wedge +EM4100 reader (~10 €) additionally says outright whether the park-buzi cards are EM4100. + +**Consequences (hold regardless of which explanation wins)** + +- **A site's card stock and its readers must be proven together.** A card enrolled at park-buzi + is not readable by the lab unit today, whatever the reason; a replacement reader must be tested + against the site's actual cards **before** it ships, or every enrolled card is orphaned — same + class of trap as the `Card Input format`. +- **Purchase spec must name the card technology and format** the site uses (the serial family is + only a hint: `H05M…` reads park-buzi's cards, `HC…` does not). Ask the vendor (support address in + the tool's title bar) which card types a given serial decodes. +- **Bench testing park-buzi card problems on the lab unit is meaningless** until the lab unit is + shown to read the site's card type. +- **Open:** with a 13.56 MHz unit the native UID is 4 or 7 bytes, so `Card Input format = 6H` + truncates it — check on the lab unit which bytes survive and whether two cards can collide on the + 6-hex value before enrolling anything against a 13.56 MHz reader ([[open-questions]]). + +Record the variant on the site record next to the serial ([[site-device-installation]] §"Record"). + +**A phone is not a card (2026-09-17).** Tapping a phone on the 13.56 MHz unit beeps and logs a +*different* id every time (`18CA08`, `37F108`, `D5A908` three seconds apart). Read backwards +those are `08 CA 18`, `08 F1 37`, `08 A9 D5`: a first UID byte of **`08`** is the ISO 14443 +marker for a **random UID**, which every phone in card-emulation mode generates per tap so that +readers cannot track the handset. So a phone can never be enrolled as an RF credential, and a +phone tap in the logs is not a clone attempt — just noise with a fresh id each time. Same for +cards with a "random ID" feature (DESFire / Mifare Plus in random-UID mode): if a card ever +enrolls but "stops matching", check whether its id changes between taps. + +Incidentally this shows what **`6H` does on a 13.56 MHz unit**: the tool prints the **first three +bytes of the 4-byte UID, byte order reversed, fourth byte dropped**. Confirm against a card with +its UID printed on the body before enrolling; the dropped byte is the collision risk in +[[open-questions]] #18. + +## Bench sink — `scripts/reader-sink.py` (2026-09-17) + +A stdlib-only Python HTTP server that answers the push on any `/qa/mcardsea.*` path with the SDK +verdict (`--accept` → status 1 / two beeps, default status 0 / one beep), `Connection: close`, and +prints one line per read: time, source IP, `serial`, `dev`, `dir` (from the `status` low digit), +`ch` (from the `Q:`/`K:` prefix), `cardid`, path. Point the reader's *Server address / Server Port* +at the laptop (`python3 scripts/reader-sink.py -p 3000 --accept`, port 80 needs admin rights). Use it +to see the raw `cardid` a card yields, to prove a reader pushes at all, and to time the beep against +the reply. No app, no DB, no Docker. + ## ⚠️ Reply MUST set `Connection: close` (verified on hardware) The reader sends `Connection: keep-alive` but **only acts on the verdict (beep/output) once the TCP diff --git a/wiki/index.md b/wiki/index.md index 35b34d1..5d10784 100644 --- a/wiki/index.md +++ b/wiki/index.md @@ -17,6 +17,7 @@ Counts: 4 sources · 19 entities · 47 concepts · 8 decision records. ## Sources - [[parking-system-architecture]] — design notes: stack, threat model, devices, UHPPOTE, ESP32, readers, BOM, open decisions. - [[dingtian-dt008]] — Dingtian DT-008 product page: QR/RFID access reader (QR/barcode + ID/IC/NFC; Wiegand/TCP-IP/USB/RS485; HTTP-GET push). +- [[dingtian-dt008-box-manual]] — the leaflet from the box: claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit, RS232 listed. - [[qrcode-sdk]] — QRCode SDK v1.6.5: the reader's HTTP-GET-poll protocol + JSON verdict (beep/output). - [[parksql2017-legacy-schema]] — predecessor SQL Server schema (Albanian market): legacy tariff/discount/membership/shift/fiscal model; confirms blocks, adds time-windows + categories, lacks postpaid sponsors. - [[ds-2cd1047g3h-liu]] — HIKVISION DS-2CD1047G3H-LIU-F datasheet: 4MP, main stream has no MJPEG option (sub does) — likely explains the model's persistent ISAPI snapshot 503 on main; confirms ISAPI/RTSP both fully in-spec. @@ -41,7 +42,7 @@ Counts: 4 sources · 19 entities · 47 concepts · 8 decision records. - [[atecc608]] — secure element; non-extractable signing key (host events + controller auth). - [[wiegand]] — reader standard feeding the controller directly (autonomous permit-holder path). - [[lpr-camera]] — edge-AI plate recognition; host-side casual-identity source; DS-2CD1047G3H-LIU main-stream ISAPI snapshot 503 is a firmware bug (only channel 102 ever works, ALL other IDs incl. garbage 503 identically) — firmware update tested, no fix; owner decided to replace the camera line rather than build an RTSP workaround. -- [[dingtian-dt008-reader]] — Dingtian DT-008 QR/RFID reader on hand; host-side serial → `read` bus (the QR-ticket scanner). +- [[dingtian-dt008-reader]] — Dingtian DT-008 QR/RFID reader on hand; HTTP-GET push, server replies the verdict; ⚠️ our two units read disjoint card sets (125 kHz vs 13.56 MHz) — unresolved, see open question #18. - [[zkteco-controller]] — ❌ rejected/historical; aux-input path was a contender, not pursued. - [[dingtian-relay]] — ✅ CHOSEN access controller; decoupled inputs solve the button blocker (driver verified on hardware); spare relays drive aux outputs (`setAux`). - [[hikvision-radar]] — vehicle-presence radar on a Dingtian input; the entry presence gate (per-input active-level caveat). diff --git a/wiki/log.md b/wiki/log.md index 446f279..f87daa9 100644 --- a/wiki/log.md +++ b/wiki/log.md @@ -3322,3 +3322,32 @@ schema: health, ingest, stats, legacy row reads back with defaults); trainer `Ha kind", /health still 200); the collector's training proxy includes the trainer's error text. Pages: [[vision-review-outbox]] (incident + rule), [[bodytype-classifier-training]] (what the message means). Deploy: nothing manual — the new collector migrates on start. + +## 2026-09-17 — DT-008 comes in two RF variants; cards are not portable between them + +Bench finding: the fresh lab DT-008 (`HC002721`) reads a set of cards park-buzi cannot, and cannot +read park-buzi's enrolled cards. NFC-phone test settled it: the phone and the lab reader detect +exactly the same set (13.56 MHz), the park-buzi set is invisible to both (125 kHz). One radio per +unit, no setting selects it, same model name. Rule: a site's readers, its card stock and any +replacement unit must be the same variant; name the variant in the purchase spec and on the site +record. Also recorded the tool's Setting-tab layout (three groups, each with its own Set button). +Pages: [[dingtian-dt008-reader]], [[site-device-installation]] §2, [[index]]. + +## 2026-09-17 — phone taps on the DT-008 are random UIDs; what `6H` keeps + +Three phone taps logged three ids ending in `08` — reversed, a first byte `08` = ISO 14443 random +UID, so phones cannot be RF credentials. Side effect: `6H` on a 13.56 MHz unit prints the first three +UID bytes reversed and drops the fourth. Pages: [[dingtian-dt008-reader]], [[open-questions]] #18. + +## 2026-09-17 — box leaflet says the DT-008 reads every card type; "one radio per unit" downgraded + +The leaflet in the lab unit's box ([[dingtian-dt008-box-manual]]) lists EM-ID, M1, ISO 14443A/B and +15693 in one reader, so the earlier "two variants, one radio each" is now one of three explanations +(variant / dead 125 kHz front end / non-EM 125 kHz cards at park-buzi). Decisive next test: a known +EM4100 fob on the lab unit. Leaflet also lists RS232 — the old "not RS-232" dismissal is withdrawn. +Pages: [[dingtian-dt008-reader]], [[site-device-installation]] §2, [[open-questions]] #18, [[index]]. + +## 2026-09-17 — `scripts/reader-sink.py`: a bench sink for the DT-008 push + +Stdlib Python HTTP server answering the reader's GET with the SDK verdict + `Connection: close`, +one log line per read (serial, dir, channel, cardid). Page: [[dingtian-dt008-reader]] §Bench sink. diff --git a/wiki/sources/dingtian-dt008-box-manual.md b/wiki/sources/dingtian-dt008-box-manual.md new file mode 100644 index 0000000..d0d41fe --- /dev/null +++ b/wiki/sources/dingtian-dt008-box-manual.md @@ -0,0 +1,39 @@ +--- +type: source +tags: [parking, hardware, readers, qr, rfid, dingtian, manual] +sources: [dingtian-dt008-box-manual] +updated: 2026-09-17 +--- + +# Source: DT-008 paper manual from the box ("QR Code Reader Technical Parameter") + +Phone-scanned (OCR) from the leaflet packed with the fresh lab unit `HC002721`, 2026-09-17. Verbatim +as OCR'd (typos are the OCR's): + +``` +QR Code Reader Technical Parameter +Voltage Support: DC 5V-16V +Current: ≤0.75W +Decoding support: QR code, one dimensional code +Reading range: ID 1~10CM, IC 1~5CM +Reading card type: EM-ID, M1, 15693, 125KHZ \ ISO14443A \ ISO14443B \ ISO15693 +Application environment: -10°C ~ 60°C +Humidity: 10% ~ 90% +Interface: Wiegand26, 34, RS485, RS232, [USB?] +``` + +## What it claims that matters + +- **All card technologies in one unit:** EM-ID (125 kHz), M1 = Mifare Classic (ISO 14443A), + ISO 14443B, ISO 15693. Range differs by technology: **ID 1–10 cm, IC 1–5 cm**. +- **RS232 is listed** — the earlier wiki position "NOT RS-232, that was a fictional-datasheet claim" + came from the mis-identified GEE PDF; the box leaflet does list it. Irrelevant to us (HTTP push), + but do not treat the interface list as evidence of a mis-id any more. +- Power 5–16 V here vs 9–16 V / 800 mA on the product page ([[dingtian-dt008]]). + +## What it does NOT settle + +The lab unit does **not** read the park-buzi card set although the leaflet says it reads EM-ID — +see [[dingtian-dt008-reader]] §"Two RF variants". Either the leaflet is generic for the line and +units ship per variant, or the lab unit's 125 kHz front end is dead/disabled, or the park-buzi +cards are a non-EM 125 kHz format (HID Prox / Indala / AWID) that only the older batch decodes.