docs(wiki): park-2 event-loop stall incident + bounded-request-cost decision; Dingtian firmware retired, dev-board pinout, edge-controller memo

- concepts/park-2-event-loop-stall: /api/sessions/active ~2 s synchronous (quote() per open
  unpaid transient x664, unindexed ledger scans) froze the loop; Node runs expired timers before
  queued UDP replies, so healthy Dingtian pulses reported "timeout" and signed entries lost
  their snapshot/session row. Standing decision: bounded request cost whatever the operator data.
- Dingtian: custom firmware retired (2026-10-23), runbook shelved, vendor pinout in raw/,
  relay-proxy PoC marked retired; edge-controller hardware memo (open).
This commit is contained in:
2026-10-24 11:17:30 +02:00
parent c08e232339
commit 6eb65361a8
14 changed files with 447 additions and 31 deletions
+4
View File
@@ -186,4 +186,8 @@ events happen that the site's [[atecc608]] signer never saw. Unresolved by desig
cloud-authored, separately signed segment the booth ingests and countersigns on return, with the
gap recorded rather than hidden. Without it, takeover is a fraud lever (pull the PC's power).
Also: exit must still fail open by hardware when the uplink is down too ([[fail-state-safety]]).
Discussion 2026-10-22: the booth's signing key stays on the booth; the cloud and the controller sign
with their own keys and the booth appends one signed "ingested segment X, gap from–to" event on
return. That requires **asymmetric** ledger signing first (today HMAC-SHA256: whoever verifies holds
the key that forges). Hardware for the controller: [[edge-controller-hardware]].