wiki: passage confirmation — zone PoC, flow and relay rules, trials, hardening list
- passage-confirmation: unexplained passages as the audit witness and the phase-1 order (2026-11-19), first recordings, and the decisions of 2026-11-22: the zone flow (last crossing counts, no decision while the zone is busy, an uncrossed open is abandoned) and the read-then-fire relay rules. - zone-anpr-poc: the prototype on park-lab, its builds, the live R2 trials and the turn-back judged as passed; park-lab as the worst-case site. - zone-anpr-plate-trials: plate reading measured (inverting does not help; the still is the main reader; the plate reads only on a short stretch of the approach), the day and wet-night trials, and the two fixes that followed. - zone-anpr-poc-review: the code review of 2026-11-21 with a status table of what the later builds fixed. - vision-hardening: the work list the user deferred to another session. - zkteco-cmp200-barrier, append-only-event-chain, reconciliation, open-questions, overview, index, log: cross-references and updates. Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01RZgP5oZdzvo92Eouc9eRv5
This commit is contained in:
@@ -2,7 +2,7 @@
|
||||
type: entity
|
||||
tags: [parking, hardware, barrier, relay, wiring]
|
||||
sources: []
|
||||
updated: 2026-11-14
|
||||
updated: 2026-11-22
|
||||
---
|
||||
|
||||
# ZKTeco CMP200 Barrier Gate
|
||||
@@ -63,10 +63,19 @@ The v1.0 board has no RS485 and no `CAR`. The 4-pin `REMOTE` header takes the 43
|
||||
permanent close command; closes on controller power loss). Per the manual a `DET` or `PHO`
|
||||
contact reverses a falling boom, so the close is not blind **if a detector is fitted** — to be
|
||||
proven on the unit (test plan steps 2–3 there) before any use.
|
||||
- **Dingtian "Mutually Exclusive" is not this interlock (user, 2026-11-21).** The board can pair two
|
||||
relays so that switching A on turns B off ("to protect the motor"). That makes the **last**
|
||||
command win: a close on relay 2 would cut a held open on relay 1. The series wiring above makes
|
||||
**open** win (relay 2 is dead while relay 1 is on), which is what [[barrier-not-a-door]] needs.
|
||||
The board setting may be enabled as well, but it does not replace the wiring, nor the `DET`/`PHO`
|
||||
proof on the unit.
|
||||
- **Status back to the host:** `O.LM OUT` and `C.LM OUT` are volt-free contacts, so they can go
|
||||
straight onto two Dingtian inputs (contact to GND, like the button). That gives the host a real
|
||||
"boom reached open / closed" signal for [[device-status-monitoring]] and for the anomaly "boom
|
||||
opened with no signed host command" ([[threat-model]]).
|
||||
- **The close does not need that signal (user, 2026-11-22).** R2 fires on an abandoned open
|
||||
without looking at the boom, and a close on a closed boom is expected to do nothing (not yet
|
||||
tried on the unit). The relay rules are on [[passage-confirmation]], "Relay rules".
|
||||
- **Sharing a detector:** a radar/loop with one dry contact cannot feed both `DET` and a Dingtian
|
||||
input directly (two different supplies on one contact). Use a detector with two relay outputs
|
||||
or an interposing relay.
|
||||
|
||||
Reference in New Issue