UHPPOTE hardware bring-up + entry-flow blocker
Brought up the real UHPPOTE controller (serial 225088491, fw 09120) end to end and recorded a procurement-level blocker. Verified on hardware: - discovery (LAN scan), host-commanded openDoor on doors 1 & 2 (physically actuated; reason="remote open door"), and live button capture (reason="push button ok"). Driver/networking fixes (packages/devices/src/drivers/access-uhppote.ts): - broadcast to subnet-directed address (lib doesn't enable SO_BROADCAST for the global 255.255.255.255 -> EACCES); - Config broadcast must match the target's subnet for unicast reply routing (fixes the health-check timeout: 5s -> 24ms ready); - discover across all local subnets, dedupe by serial; - serialize all controller I/O (concurrent calls collided on UDP :60001). Server/UX: - load .env via node --env-file-if-exists (vars weren't being read before); - SETUP_AUTH_BYPASS hardened: env-gated, dev + loopback only, fails closed otherwise; surfaced as catalog.authBypass so the wizard drops the token field; - .env.example documents all vars; inline favicon stops a 404. - apps/server/scripts/: uhppote-listen (live events, restores prior listener) and uhppote-relay (guarded door-open test). BLOCKER (wiki/decisions/access-controller-button-flow.md): the controller's push-button input auto-opens the relay in firmware with no report-without-open mode, so ticket-first entry (button -> print -> open, fail-closed) is impossible as wired. UHPPOTE can't do it on that input; ZKTeco *might* via a programmable aux input + PULL SDK but that's unverified and needs a new driver. Entry-lane hardware decision paused to focus on the business side. wiki: access-controller-button-flow (blocker), zkteco-controller (stub + assessment), uhppote-controller callout, index + log.
This commit is contained in:
@@ -11,6 +11,16 @@ The starting access-control hardware: a **UHPPOTE Wiegand 26/34 network controll
|
||||
a cheap reader-plus-relay frontend, acceptable **provided you understand its limits**. The plan
|
||||
is UHPPOTE now → ZKTeco later (see [[bom]]). (See [[parking-system-architecture]] §6.)
|
||||
|
||||
> **⚠️ Entry-flow blocker (verified on hardware):** the push-button input **auto-opens the relay
|
||||
> in firmware** — there's no command to make it report-without-opening — so it **cannot** do
|
||||
> ticket-first entry (`button → print → open`). Fine as a host-**commanded relay** and for
|
||||
> [[wiegand]]/permit lanes, but **not** the button-driven entry lane as wired. Full detail and
|
||||
> options: [[access-controller-button-flow]].
|
||||
>
|
||||
> **Verified working on the real unit** (serial 225088491, fw 09120): host-commanded `openDoor`
|
||||
> on doors 1 & 2 (physically actuated, `reason="remote open door"`); button presses captured live
|
||||
> (`reason="push button ok"`); [[device-discovery]] scan. Test scripts: `apps/server/scripts/`.
|
||||
|
||||
> **Implementation:** integrated via the official **`uhppoted`** npm package (MIT, by the
|
||||
> `uhppoted` org — `github.com/uhppoted/uhppoted-lib-nodejs`), added to `@parking/devices` as the
|
||||
> `uhppote` access driver ([[device-registry]]). It exposes exactly the protocol commands this
|
||||
|
||||