julian 35e593ab63 docs(wiki): DT-008 phantom-scan diagnosis + backfill bypass/relay-test concept pages
Two independent wiki updates bundled (all docs):

1. dingtian-dt008-reader.md: phantom optical decodes on the park-buzi EXIT
   reader (empty pre-opening site, low-sun afternoons). Chain of evidence:
   READ log lines carry the reader's own serial (H05MA5B0) → physical device,
   not a network source; snapshot shows nobody present; code shapes are the
   giveaway (6-digit numerics = checksum-less Interleaved 2-of-5, lone "C" =
   Code39/Codabar artifact) → 1D engine decoding sun-made stripe patterns
   (striped arm, fence shadows, glare). No fraud exposure (11-digit Luhn ids
   can't match); noise only. Fix on the entity page: vendor-tool symbology cut
   to QR+Code128 + min decode length, BOTH readers; config lives ON the device
   → re-apply after any factory reset/swap. Deliberately NOT filtering
   impossible codes server-side — probe recording is the anomaly path's job.

2. Backfilled two shipped-but-undocumented features (six code files already
   linked the first page as if it existed):
   - concepts/entry-presence-bypass.md — admin drops a FAULTY presence signal
     (granular radar/camera by decision, not a master switch); every flip is a
     signed config_change; persists till off; tickets stamped presenceBypassed;
     radar-bypass cooldown tradeoff; "the admin is not the adversary, but
     trusted never means invisible".
   - concepts/setup-relay-test.md — admin-only commissioning pulse, signed
     barrier_open_command BEFORE the fire so a test open never reads as the
     out-of-band-open fraud signal; saved controllers/declared relays only;
     radarAlert lamps excluded; pulseOpen only.
   Cross-linked from operator-issued-entry.md, cataloged in index.md, logged.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-07-04 19:00:49 +02:00
julian f6e35bbebf fix(reader): correct the QR reader's identity — Dingtian DT-008, not "GEE"
Build desktop / desktop (push) Successful in 4m16s
Build & push images / images (push) Successful in 2m46s
CI / check (push) Successful in 38s
An early wrong assumption named the QR/RFID access reader "GEE" /
"GEE/Fondvision" / "GEE-QR-ER80" (and summarized a raw GEE PDF as its
datasheet). There is no GEE device — it's the Dingtian DT-008
(dingtian-tech.com/en_us/qr_code_reader.html), the same vendor as the relay
board, which is why it integrates the identical HTTP-GET-push way.

Code:
- Driver symbol geeQrReaderDriver → dingtianQrReaderDriver; label →
  "Dingtian DT-008 QR/RFID reader (HTTP push)"; comments/description rewritten
  to the real DT-008 facts (Wiegand 26/34, TCP/IP, USB, RS485 — not RS-232;
  QR/barcode + ID/IC/NFC — not DataMatrix/1D).
- Persisted driverId "gee-qr-reader" → "dingtian-qr-reader" (the registry
  lookup key + the row created on assign in qr-reader.ts).
- Migration 0015 rewrites existing devices.driver_id rows so configured readers
  keep resolving (applied to the dev DB — 2 rows; the booth applies it on boot).
  Behaviour is unchanged: naming + the persisted id only.

Wiki + memory:
- Renamed entities/gee-qr-er80.md → dingtian-dt008-reader.md and
  sources/gee-qr-er80.md → dingtian-dt008.md; rewrote both to the real DT-008
  product-page specs while KEEPING all the verified-on-hardware protocol facts
  (cjihao serial, .jsp path, Connection: close). Fixed every cross-reference +
  "GEE" mention in 6 other pages. Memory gee-reader-serial-binding →
  dingtian-reader-serial-binding. The only surviving "GEE" mentions are
  deliberate naming-correction notes, the raw PDF filename, and the
  append-only log history.

Full workspace build/lint/test green; dev DB readers verified resolving to the
registered dingtian-qr-reader driver.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V