julian 4593a397dd fix(devices): Dahua snapshot channel is 1-based; add Dahua clock sync; wiki page for the bench IPC-HFW2549T
Build & push images / images (push) Successful in 3m25s
The dahua driver decremented the wizard's channel on the belief the CGI is
0-based. On real hardware (IPC-HFW2549T-AS-IL, fw V2.880, 2026-09-17)
snapshot.cgi?channel=0 answers HTTP 400 and channel=1 returns the 2880x1620
JPEG — so every Dahua assignment sat at degraded "HTTP 400". The channel is
now sent as entered (clamped >= 1) and the URL is pinned in camera.test.ts.

DahuaCamera.syncClock reads global.cgi getCurrentTime and, past the drift
limit, writes setCurrentTime with the host's naive local wall time (no offset):
the OSD burned into snapshots must match the booth clock; the camera's tz/DST
config is left alone. Verified live: a 2h-off set, set back, 1s drift -> no
write. The device monitor picks it up via isClockSyncable unchanged.

Wiki: new entities/dahua-ipc-hfw2549t.md (endpoint table, verbatim
eventManager attach parts — VideoMotion Start/Stop, VideoMotionInfo,
TimeChange — RealUTC is the camera's belief of UTC, 5-strike login lockout,
unit not factory-fresh); lpr-camera Dahua bullet corrected; runbook §3 Dahua
paragraph; index + log. The server-side attach-stream subscriber is not built.
2026-10-08 08:03:50 +02:00
julian 4d1d245680 docs(wiki): DT-008 card-technology findings, box leaflet source, install checklist; add scripts/reader-sink.py
Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only)
although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as
unresolved with the EM4100 test that settles it (open question #18). Phone taps give a
random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID
bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification
checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink
answering the push with the SDK verdict and Connection: close.

Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
2026-09-17 09:47:40 +02:00
julian 4a02e5fed3 docs(wiki): site device installation — the field runbook for what to know before the booth
Build & push images / images (push) Successful in 2m50s
Per device (Dingtian relay board, DT-008 readers, Hikvision G3H camera, radar,
K200L / Rongta / Cashino printers): factory address and login, the tool needed,
what the wizard configures by itself on assign vs what is done by hand on the
device, how to verify, and the traps already paid for (unauthenticated Dingtian
CGI + session_en brick, duplicate reader IP, reader settings lost on reset, sub
stream mandatory, Alarm Server after assign + Vehicle target filter, close the
camera web UI, radar idle level, "Test" only probes a printer). Bring list, the
10.0.10.x address plan beside each factory address, the on-site order of work,
and the gaps still unrecorded. Linked from appliance-provisioning and the K200L
page; log entries for the day.

Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
2026-09-09 12:34:59 +02:00