julian c08e232339 feat(firmware): relay-proxy PoC — NodeMCU as a Dingtian DT-R004 + cloud proxy/watchdog
A NodeMCU v3 (ESP8266) that speaks the Dingtian wire contract (binary UDP 60000 with
relay_pw, string UDP 60001, config CGI incl. the setconfig gotcha, userset.cgi, Digest
input push) so the booth's existing driver needs no change, plus a heartbeat/command/
watchdog path to an ephemeral cloud stand-in (poc/cloud-standin.mjs). Verified at park-lab:
the booth's assign flow configured it like real hardware and a button press reached the
booth (401→Digest→200) and the cloud with the booth's status. Watchdog probes /health and
power-cycles the PC via a spare relay with backoff. IO behind one interface for the ESP32/
Dingtian port.

wiki: relay-proxy-firmware page; esp32-flashability-test runbook (esptool lock test);
dingtian-relay "can we flash our own firmware" (vendor locks the standard SKU);
site-device-installation: booth ufw must allow device-net → 3000 (push targets PORT, not
Caddy's 80); open-questions: cloud takeover vs signed ledger (parked).

.gitignore: firmware venv/.pio/secrets.h.
2026-10-22 12:08:20 +02:00
julian 30a1180108 feat(review): sample every detected car, not only ticketed entries
Build & push images / images (push) Successful in 5m20s
The entry stream for the reviewer was fed from the session-tied read only (ticket
printed / exit signed). park-2 ran an afternoon with its barriers up: hundreds of
camera vehicle pushes, zero tickets, zero samples.

- anpr-entry: keep the best-framed vehicle of each poll loop (highest body-type
  confidence with a box), store that frame as a snapshot (identity pass:<id>, no
  session) and emit a vehicle read with the camera id — plate or no plate. One
  sample per detection, fire-and-forget, never on the ANPR path.
- snapshot.ts: normalizedBoxes() shared by the session-tied read and the bridge;
  vehicle reads now carry deviceId.
- review-outbox: sampleEntry(deviceId) dedups per camera for 30 s so the pass
  sample and a ticket entry's read (same car, seconds apart) go once.
- wiki: outbox page (entry stream, troubleshooting checklist for 'nothing arrives':
  the month-long silence was a missing Netbird policy, not code), park-2 camera
  port-forward procedure (site-device-installation §7), log.
2026-10-08 19:30:03 +02:00
julian b7efa081ec feat(devices): DT-008 reader discovery + auto-configuration over the vendor UDP protocol
Build & push images / images (push) Successful in 3m7s
The Dingtian DT-008's Windows-only config tool speaks a small binary UDP protocol
(reader :24680 unicast get/set, :24582 broadcast search/set-network), reversed in
wiki/raw/dingtian_qr_linux (PROTOCOL.md + dingtian_qr.py, copied to scripts/). Reading
park-2's readers with it from the booth found both in WG26 output mode — the "beeps but
captures nothing" enrolment failure: they never pushed HTTP at all.

The app now speaks the protocol itself (packages/devices dingtian-qr-config.ts, Node dgram,
host-network container) and the dingtian-qr-reader driver uses it:
- discover(): first driver to implement the wizard's Scan capability; rows show serial, IP,
  output mode, current server target, card format, firmware.
- preconditions: output type must be HTTP (fixable — save switches it); typed serial must
  equal the reported one and the reader must answer on UDP (both block the save).
- configureInputPush(): set-network the reader's server to this booth's IP + listen port,
  confirmed by polling (the reader applies it without an ack and is silent for seconds).
- usesPushAuth=false: the scan GET carries no credentials, so no push secret is stored.
- a reader saved without an IP warns instead of failing (legacy vendor-tool setup).

Verified on the bench unit: WG26→HTTP, target 8080→8081→8080, struct byte-identical after.
15 protocol tests against a fake reader + 17 adapter tests. Wiki: device-discovery,
first-run-setup, dingtian-dt008-reader, site-device-installation §2 (SSH procedure; the
"needs a Windows laptop" claim withdrawn), new source page dingtian-qr-linux-tool.
2026-10-08 15:22:33 +02:00
julian 4593a397dd fix(devices): Dahua snapshot channel is 1-based; add Dahua clock sync; wiki page for the bench IPC-HFW2549T
Build & push images / images (push) Successful in 3m25s
The dahua driver decremented the wizard's channel on the belief the CGI is
0-based. On real hardware (IPC-HFW2549T-AS-IL, fw V2.880, 2026-09-17)
snapshot.cgi?channel=0 answers HTTP 400 and channel=1 returns the 2880x1620
JPEG — so every Dahua assignment sat at degraded "HTTP 400". The channel is
now sent as entered (clamped >= 1) and the URL is pinned in camera.test.ts.

DahuaCamera.syncClock reads global.cgi getCurrentTime and, past the drift
limit, writes setCurrentTime with the host's naive local wall time (no offset):
the OSD burned into snapshots must match the booth clock; the camera's tz/DST
config is left alone. Verified live: a 2h-off set, set back, 1s drift -> no
write. The device monitor picks it up via isClockSyncable unchanged.

Wiki: new entities/dahua-ipc-hfw2549t.md (endpoint table, verbatim
eventManager attach parts — VideoMotion Start/Stop, VideoMotionInfo,
TimeChange — RealUTC is the camera's belief of UTC, 5-strike login lockout,
unit not factory-fresh); lpr-camera Dahua bullet corrected; runbook §3 Dahua
paragraph; index + log. The server-side attach-stream subscriber is not built.
2026-10-08 08:03:50 +02:00
julian 4d1d245680 docs(wiki): DT-008 card-technology findings, box leaflet source, install checklist; add scripts/reader-sink.py
Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only)
although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as
unresolved with the EM4100 test that settles it (open question #18). Phone taps give a
random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID
bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification
checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink
answering the push with the SDK verdict and Connection: close.

Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
2026-09-17 09:47:40 +02:00
julian 4a02e5fed3 docs(wiki): site device installation — the field runbook for what to know before the booth
Build & push images / images (push) Successful in 2m50s
Per device (Dingtian relay board, DT-008 readers, Hikvision G3H camera, radar,
K200L / Rongta / Cashino printers): factory address and login, the tool needed,
what the wizard configures by itself on assign vs what is done by hand on the
device, how to verify, and the traps already paid for (unauthenticated Dingtian
CGI + session_en brick, duplicate reader IP, reader settings lost on reset, sub
stream mandatory, Alarm Server after assign + Vehicle target filter, close the
camera web UI, radar idle level, "Test" only probes a printer). Bring list, the
10.0.10.x address plan beside each factory address, the on-site order of work,
and the gaps still unrecorded. Linked from appliance-provisioning and the K200L
page; log entries for the day.

Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
2026-09-09 12:34:59 +02:00