The Dingtian DT-008's Windows-only config tool speaks a small binary UDP protocol
(reader :24680 unicast get/set, :24582 broadcast search/set-network), reversed in
wiki/raw/dingtian_qr_linux (PROTOCOL.md + dingtian_qr.py, copied to scripts/). Reading
park-2's readers with it from the booth found both in WG26 output mode — the "beeps but
captures nothing" enrolment failure: they never pushed HTTP at all.
The app now speaks the protocol itself (packages/devices dingtian-qr-config.ts, Node dgram,
host-network container) and the dingtian-qr-reader driver uses it:
- discover(): first driver to implement the wizard's Scan capability; rows show serial, IP,
output mode, current server target, card format, firmware.
- preconditions: output type must be HTTP (fixable — save switches it); typed serial must
equal the reported one and the reader must answer on UDP (both block the save).
- configureInputPush(): set-network the reader's server to this booth's IP + listen port,
confirmed by polling (the reader applies it without an ack and is silent for seconds).
- usesPushAuth=false: the scan GET carries no credentials, so no push secret is stored.
- a reader saved without an IP warns instead of failing (legacy vendor-tool setup).
Verified on the bench unit: WG26→HTTP, target 8080→8081→8080, struct byte-identical after.
15 protocol tests against a fake reader + 17 adapter tests. Wiki: device-discovery,
first-run-setup, dingtian-dt008-reader, site-device-installation §2 (SSH procedure; the
"needs a Windows laptop" claim withdrawn), new source page dingtian-qr-linux-tool.
An early wrong assumption named the QR/RFID access reader "GEE" /
"GEE/Fondvision" / "GEE-QR-ER80" (and summarized a raw GEE PDF as its
datasheet). There is no GEE device — it's the Dingtian DT-008
(dingtian-tech.com/en_us/qr_code_reader.html), the same vendor as the relay
board, which is why it integrates the identical HTTP-GET-push way.
Code:
- Driver symbol geeQrReaderDriver → dingtianQrReaderDriver; label →
"Dingtian DT-008 QR/RFID reader (HTTP push)"; comments/description rewritten
to the real DT-008 facts (Wiegand 26/34, TCP/IP, USB, RS485 — not RS-232;
QR/barcode + ID/IC/NFC — not DataMatrix/1D).
- Persisted driverId "gee-qr-reader" → "dingtian-qr-reader" (the registry
lookup key + the row created on assign in qr-reader.ts).
- Migration 0015 rewrites existing devices.driver_id rows so configured readers
keep resolving (applied to the dev DB — 2 rows; the booth applies it on boot).
Behaviour is unchanged: naming + the persisted id only.
Wiki + memory:
- Renamed entities/gee-qr-er80.md → dingtian-dt008-reader.md and
sources/gee-qr-er80.md → dingtian-dt008.md; rewrote both to the real DT-008
product-page specs while KEEPING all the verified-on-hardware protocol facts
(cjihao serial, .jsp path, Connection: close). Fixed every cross-reference +
"GEE" mention in 6 other pages. Memory gee-reader-serial-binding →
dingtian-reader-serial-binding. The only surviving "GEE" mentions are
deliberate naming-correction notes, the raw PDF filename, and the
append-only log history.
Full workspace build/lint/test green; dev DB readers verified resolving to the
registered dingtian-qr-reader driver.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
Two genuinely-offline QR readers showed GREEN: the adapter's healthCheck was
hardcoded to { ready, "stub" } and never probed. These are PUSH devices (scan →
GET our backend, resolve by serial) with NO TCP port, so a connect probe has
nothing to hit — the stub "solved" that by lying. False-healthy is the worst
failure for a status bar.
- Optional reader IP field (monitor-ONLY; scans still resolve by serial,
operation unchanged).
- Unprivileged ICMP ping (drivers/icmp.ts): shells /bin/ping -c1, exit-0 = reply.
No native dep, no CAP_NET_RAW. docker-compose.prod.yml sets
net.ipv4.ping_group_range so it works for the non-root container user.
- healthCheck: replies → ready, no reply → offline, NO IP → degraded
("set IP to monitor") — never a false green.
Verified on hardware: readers (10.0.10.7/.8) answer ICMP on the device VLAN;
UI Test connection → "● ready — ping 10.0.10.7". Tests: reader.test.ts (4).
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V