Add a third data stream (app_logs), distinct from the signed ledger and device
telemetry, for operational/diagnostic logs — an offline appliance has no Sentry to
ship to, so the host is the log store.
Backend: a pino stream tees warn/error/fatal into app_logs (info/debug stay
stdout-only) with no call-site change; the DB is built before Fastify so the logger
has its sink. Frontend (lib/logger.ts): ships failed API requests (minus 401 churn),
window.onerror, unhandledrejection, and a top-level React ErrorBoundary; console
warn/error forwarded only at debug/trace. Batched/throttled POST, sendBeacon on
pagehide, loop-safe (never logs the /api/logs call), best-effort everywhere.
POST /api/logs (any signed-in user, CSRF, tolerant) + GET /api/logs gated by a new
log:read permission (new `log` RBAC resource; admin holds it). Retention: pruned by
age + row cap, hourly + at startup. UI: a Logs screen under /setup (filter
level/source/since, expand to context+stack), sq+en. Migration 0009_app_logs.
Verified end-to-end via app.inject: login -> POST 204 -> GET 200 with the record;
backend warn/error persisted, info dropped; non-admin GET 403 / POST 204.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
A parking lot is one pool of spaces with a flexible set of entry/exit
points — no "lane". Direction is a property of each RELAY inside an access
controller; readers/cameras bind to a controller relay and inherit it.
Schema:
- drop `lane` from ledger_events, device_events, sessions
- rename lane_devices -> devices (no lane/direction columns)
- access config.relays=[{relay,direction,button?}]; reader/camera
config.controllerId+relay binding
- fresh 0000_baseline migration (history reset; dev data was throwaway)
Signed ledger:
- remove `lane` from canonicalize(); bump signer keyId sw-hmac-v1 -> v2
(v1 events won't verify under v2 — intentional, gated per-event by keyId)
Server:
- new device-resolve.ts (replaces lane-map.ts): relayForButton,
relayForDevice, firstRelayByDirection, devicesByDirection
- entry-flow: button terminal -> its relay; exit/permit: reader's bound
relay; dispatcher resolves the bound relay + inherited direction
- camera snapshots fire by direction site-wide, async, never block open
- DeviceConfig widened to nested JSON for relays[]
Web:
- wizard: no lane selector; add controllers (relay map + entry-button
terminal) first, then bind readers/cameras/printers to a controller relay
Wiki: new entry-exit-points.md (replaces lane-direction); reworked
entry-exit-readers, parking-session, first-run-setup, device-registry,
append-only-event-chain, device-events; removed stale lane/LaneMap mentions.
Correction before schema work: the events table conflated the anti-fraud
business ledger with device telemetry. Decision: ledger_events (signed,
chained, reconciled) holds only business facts; device_events (unsigned,
prunable) holds relay/printer/camera/reader/input telemetry. A raw button
press is telemetry; the entry flow mints a signed vehicle_entry. Drops
input_received-as-signed-event.
New: decisions/event-streams-split, concepts/device-events; updated
append-only-event-chain, index, log.