Footer camera chips open/close a tile per camera (bottom right, ~15% wide, stacking
leftwards); the open set is a per-user preference (users.open_cameras). A tile shows the
camera's newest entry/exit snapshot and switches to live video while that camera pushes
vehicle events (per-camera activity, same 30 s TTL as lane status).
- devices: RTSP MJPEG client + RFC 2435 RTP/JPEG reassembly; Hikvision openLiveStream()
on the sub-stream (x02, must be MJPEG — H.264 is refused with that reason)
- server: CameraLiveHub (one shared upstream per camera, latest-frame delivery, fps cap,
linger, backoff), CameraActivity, /api/cameras/:id/latest-snapshot, WS
/api/cameras/:id/live (shared handshake auth with /api/ws + device:read),
PUT /api/auth/open-cameras, migration 0033 (open_cameras + snapshot device/time index)
- web: CameraDock, footer toggles, binary frames in the platform socket (Tauri too)
- .gitattributes: *.jpg / *.bin binary (byte-exact test fixtures)
Verified on park-lab cameras end to end and in headless Firefox.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
park-2's cameras burned Beijing time into every frame: factory zone CST-8,
and the sync compared instants only, so zero drift meant the zone was never
touched. The G3H firmware also accepts a POSIX zone with a DST rule, echoes
it back, and ignores the rule.
syncClock now derives the site's current UTC offset as a fixed Hikvision
zone (hikvisionFixedZone) and rewrites it when it differs, sending the clock
with it. The device monitor adds a third trigger beside offline->ready and
the 24h backstop: the moment the site's UTC offset changes, so a DST switch
is handled within one poll. ClockSyncResult reports zoneChanged/timeZone.
Both park-2 cameras were set to CST-2:00:00 by hand on 2026-10-09; this
must be deployed there before 2026-10-25 or the OSD reads 1h ahead from
that day until it is.
Measured on park-2 minutes after a redeploy: 128 server lines / 15 min, 60 of them the Docker
HEALTHCHECK's /health logged as "incoming request" + "request completed"; 160 vision lines,
143 of them uvicorn access lines for GET /health (Docker's probe + the booth server's footer
chip polling every 8 s). Levels were never the problem — all of it was info.
- server: /health route logLevel "silent"; disableRequestLogging + an onResponse hook that
logs one line "METHOD url → status Nms". That flag also stops Fastify's default error
handler from logging handler errors, so an onError hook logs 5xx with the stack
(fastify 5.8.5 lib/error-handler.js checks the same flag). Pinned by request-logging.test.ts.
- vision: a logging.Filter on uvicorn.access drops /health access lines (tested).
- devices: stubLog gains a level; the per-snapshot "captureSnapshot (N bytes)" line is
debug; the hik-alarm HIT line is debug (ACCEPTED/REJECTED carry everything).
LOG_LEVEL=debug restores all of it. Wiki: app-logs §Noise cut.
The dahua driver decremented the wizard's channel on the belief the CGI is
0-based. On real hardware (IPC-HFW2549T-AS-IL, fw V2.880, 2026-09-17)
snapshot.cgi?channel=0 answers HTTP 400 and channel=1 returns the 2880x1620
JPEG — so every Dahua assignment sat at degraded "HTTP 400". The channel is
now sent as entered (clamped >= 1) and the URL is pinned in camera.test.ts.
DahuaCamera.syncClock reads global.cgi getCurrentTime and, past the drift
limit, writes setCurrentTime with the host's naive local wall time (no offset):
the OSD burned into snapshots must match the booth clock; the camera's tz/DST
config is left alone. Verified live: a 2h-off set, set back, 1s drift -> no
write. The device monitor picks it up via isClockSyncable unchanged.
Wiki: new entities/dahua-ipc-hfw2549t.md (endpoint table, verbatim
eventManager attach parts — VideoMotion Start/Stop, VideoMotionInfo,
TimeChange — RealUTC is the camera's belief of UTC, 5-strike login lockout,
unit not factory-fresh); lpr-camera Dahua bullet corrected; runbook §3 Dahua
paragraph; index + log. The server-side attach-stream subscriber is not built.
park-buzi field observation: after a power cut the Hikvision cameras
reboot at the 1970 epoch (no/dead RTC battery, no NTP) and stay there
until a human logs into the web UI (which silently pushes the browser
clock) — corrupting the snapshot OSD timestamps (the evidence trail) and
ANPR push times meanwhile.
The host is the site's time authority (offline-first, no NTP infra):
- Device monitor triggers a sync at each camera's offline→ready edge —
exactly the power-restored moment — plus a 24h backstop; the attempt
is stamped before the async call so a failing camera retries at
backstop cadence, never every poll.
- HikvisionCamera.syncClock: GET /ISAPI/System/time; drift ≤60s → leave
alone; beyond (or unparseable = infinite drift) → PUT timeMode=manual
with the site wall-clock now WITH explicit utc offset
(localIsoWithOffset), echoing the camera's timeZone verbatim — correct
the clock, never fight its tz/DST config.
- Jumps >1h (the power-cut signature) log warn (persisted to app_logs);
small corrections info. Capability-guarded (isClockSyncable) —
hikvision only; dahua's CGI has no such endpoint.
- http-digest generalised to digestRequest (GET/PUT/POST + body); the
handshake was already method-aware. digestGet delegates unchanged.
8 new tests: in-sync no-op, 1970 PUT shape (manual + host instant +
echoed tz), unparseable→sync, failed-set surfaces, dahua non-capability,
DST-both-sides pins on the offset formatter.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
The device monitor logs + re-emits a status only when state OR detail
changes, but the camera probe's detail was the exact snapshot byte count,
which differs on every JPEG frame — so healthy cameras "changed" on
nearly every poll, writing a log line + websocket event each time
(inflating the freshly budgeted container logs). The detail is now a
stable power-of-two bucket ("snapshot ≈16 KB" / "≈256 KB") that moves
only on a real shift (stream/resolution change); an empty-ish 200 body
is flagged as "<1 KB" rather than bucketed away. Failure details
(auth/HTTP/timeout) unchanged. 3 tests pin the no-flap behavior.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
The Hikvision driver's create() had a leftover `console.log(c)` that dumped the
ENTIRE camera config — including the plaintext `password` — to stdout every time
the adapter was built, on every request that resolves a camera. That puts a device
credential in the logs (which get shipped/cached/read — the booth operator is the
adversary). Removed. Swept the rest of the shipped source: no other console.* leaks.
A Hikvision DS-2CD1047G3H-LIU returned HTTP 503 (statusCode 2 / deviceBusy)
on EVERY main-stream snapshot — its main encoder is persistently saturated.
Probed on hardware: channels/101/picture → 503 on 5 consecutive tries, while
channels/102/picture (sub stream) → 200 clean JPEG every time. A retry loop
can't fix a persistent busy; the real fix is stream selection.
- Add a `stream` config field to the Hikvision driver (1=main, default for
back-compat; 2=sub). ISAPI channel id is <channel><stream> (101 main, 102 sub).
Verified live: setting the G3H to Sub flips its status degraded→ready (14.7KB
JPEG in ~87ms).
- captureSnapshot also retries the TRANSIENT case (503/500, linear backoff
250/500/750ms ×4) then fails naming it "(device busy)"; does NOT retry 401/404
(config errors won't self-heal). Complements captureSnapshotShared (concurrent
de-dup). healthCheck still reports a live 503 as degraded (surfaces a saturated
main stream rather than hiding it).
Tests: camera.test.ts (10) — retry behaviour + main/sub path selection.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
Diagnosed why no camera push ever landed: (1) the route only registered
POST/GET, so a probe with another method got a generic 404 the camera
reads as "service available" while our handler never ran; (2) more
fundamentally, WSL mirrored mode REWRITES the inbound source IP to the
host's own address (10.0.10.203), so the camera's real IP (10.0.10.12)
never survives and the source-IP guard rejected every push as a mismatch.
- Register the event route on POST/GET/PUT/PATCH/DELETE/OPTIONS (HEAD comes
with GET) so ANYTHING hitting the path reaches the handler and is recorded.
- Log + store the HTTP method of each hit; log every hit on arrival, before
any guard, so even a rejected probe is visible immediately.
- Add per-device skipSourceIpCheck (a Setup checkbox) to bypass the
source-IP guard where the network rewrites the source (WSL). Digest auth +
the signed ledger remain the real guards.
Tests: hik-alarm 10 (skip-IP accept + method capture). server green;
web build green (new checkbox renderer + this field).
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
Newer Hik firmware can PUSH events to us: Event -> Smart/VCA with
"Detection Target: Human/Vehicle" + Notify Surveillance Center + Alarm
Settings -> Alarm Server makes the camera HTTP-POST an
EventNotificationAlert on each detection.
- New POST /api/devices/hikvision/:deviceId/event (routes/hikvision-alarm.ts):
same machine-push pattern as the Dingtian Input Link — source-IP guarded
+ optional HTTP Digest, not behind the SPA cookie/CSRF.
- Discovery-first / permissive: a wildcard content-type parser accepts ANY
body as raw bytes (event XML, multipart+JPEG, or JSON — Hik varies by
firmware), records it verbatim as a kind:"alarm" device_event, and
best-effort extracts eventType/target/plate/dateTime/channelID for the
summary + a loud log line. The point is to SEE exactly what a camera
sends before wiring it further.
- hikvision driver gains alarmPushEnabled + pushUser/pushPassword config and
pushesToBackend:true (setup offers the backend push IP).
- NOT yet a barrier trigger / DeviceReadEvent — records only. A plate read
is advisory, never the sole reason a barrier opens; the read-bus/ANPR
wiring is a deliberate next step once the real payload is known.
Tests: hikvision-alarm.test.ts (6: vehicle XML summary, ANPR plate, raw
JSON, wrong-IP 404, disabled 404, unknown-device 404). server 109/109;
build+lint 14/14. Wiki: lpr-camera.md + log.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
A parking lot is one pool of spaces with a flexible set of entry/exit
points — no "lane". Direction is a property of each RELAY inside an access
controller; readers/cameras bind to a controller relay and inherit it.
Schema:
- drop `lane` from ledger_events, device_events, sessions
- rename lane_devices -> devices (no lane/direction columns)
- access config.relays=[{relay,direction,button?}]; reader/camera
config.controllerId+relay binding
- fresh 0000_baseline migration (history reset; dev data was throwaway)
Signed ledger:
- remove `lane` from canonicalize(); bump signer keyId sw-hmac-v1 -> v2
(v1 events won't verify under v2 — intentional, gated per-event by keyId)
Server:
- new device-resolve.ts (replaces lane-map.ts): relayForButton,
relayForDevice, firstRelayByDirection, devicesByDirection
- entry-flow: button terminal -> its relay; exit/permit: reader's bound
relay; dispatcher resolves the bound relay + inherited direction
- camera snapshots fire by direction site-wide, async, never block open
- DeviceConfig widened to nested JSON for relays[]
Web:
- wizard: no lane selector; add controllers (relay map + entry-button
terminal) first, then bind readers/cameras/printers to a controller relay
Wiki: new entry-exit-points.md (replaces lane-direction); reworked
entry-exit-readers, parking-session, first-run-setup, device-registry,
append-only-event-chain, device-events; removed stale lane/LaneMap mentions.
Replace the camera stub with HttpCamera: Hikvision ISAPI and Dahua CGI
snapshots over client-side HTTP Digest (new drivers/http-digest.ts).
healthCheck() now pulls a real frame instead of returning ready/stub.
Snapshot carries bytes (driver fetches); storage/imageRef is the caller's
job, keeping the adapter free of storage deps.
Fix the cosmetic Backend-push-IP field: add pushesToBackend to DeviceDriver
(only Dingtian sets it), expose as pushCapable in the catalog, and gate the
wizard's backend-IP fetch + field on it so pull-only devices hide it.
Verified on hardware (Hikvision 10.0.10.121): healthCheck ready,
captureSnapshot returns a valid JPEG.
Make the device-adapter pattern selectable so the admin chooses hardware at
install — per lane, from a catalog of supported drivers. Adding a device =
registering one more driver; no business-logic change.
packages/devices:
- interfaces.ts: AccessControlDevice / ReaderDevice / CameraDevice / PrinterDevice
(adds CameraDevice for entry/exit snapshot-on-event; access relay stays
intent-only per "a barrier is not a door").
- registry.ts: driver catalog with per-driver config fields + factory, config
validation, and a catalog payload for the setup UI.
- drivers/: stub adapters — access (zkteco, esp32-relay), reader (wiegand,
tcp-ip), camera (hikvision, dahua). Real vendor protocols TBD.
packages/db:
- lane_devices + setup_state tables (migration 0001); re-export query helpers.
apps/server:
- routes/setup.ts: GET /api/setup/catalog (public schema), and admin-only
/assign, /state, /complete with registry validation before persisting.
- extract auth.ts (requireJwtSecret, requireRole, JWT type aug).
apps/web:
- SetupWizard scaffold + api client: pick a driver per category for a lane,
render its config fields.
wiki: device-registry + first-run-setup concept pages; cross-link from
device-adapter-pattern; index + log updated.
Verified: full turbo build (5/5); catalog lists all drivers; admin assign
persists; missing-config and no-token requests are rejected.