Commit Graph

34 Commits

Author SHA1 Message Date
julian 420542ce10 fix(setup): add Dingtian relay-password field + secure secret re-merge on test
The relay control password (relay_pw) was read by the driver but had NO form field,
so Test connection sent it as 0 → the device ignored the probe → a controller showed
"offline" even though it pinged. Add a "Relay control password" config field (secret;
blank keeps the stored value).

Because relayPassword is redacted from the client, the edit form can't resend it — so
the test endpoint now re-merges the stored secret by device id (mirroring save). It is
re-merged ONLY when the submitted config addresses the SAME device: matching driverId
and every connection-identity field it sets (host/port/binaryPort/httpPort/serial). A
redirected host/port or mismatched driver yields NO secret, so a probe can't exfiltrate
the password to an attacker host (the booth operator is the threat-model adversary).
testDevice() now passes the device id; setup-secrets.test.ts covers the identity guard.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-24 19:03:53 +02:00
julian 2915d141aa feat(devices): radar presence input + button-light output on the controller
Model the entry button (I1) and a Hikvision radar (I2) as named children of the
access controller, and drive the button's 12V lamp on a spare relay.

- Radar = the existing relays[].presenceInput one-car-one-ticket gate, now labelled
  presenceKind: loop|radar. A radar may idle opposite the button, so add a per-input
  active-level override: relays[].presenceActiveLow -> driver inputActiveLow set,
  inverting just that terminal (pure helper inputActive()). The Dingtian has one
  board-wide resting level otherwise.
- AuxOutputDevice.setAux(channel,on) capability on the device interface (Dingtian
  latch) so business logic drives a NON-barrier lamp through the interface. Barriers
  still only pulseOpen — barrier-not-a-door preserved.
- ButtonLightController: subscribes to the radar input edge + the camera lane status
  and drives a 3-state lamp — radar+car=solid, radar-only=blink (~1Hz), else off.
  Fails OFF on host loss/error; de-duped. A radar detection never opens a barrier on
  its own (advisory; threat model).
- SetupWizard: presence kind + active-low + a button-light relay picker; sq+en i18n.

Tests: button-light.test.ts (truth table + blink + fail-OFF + de-dupe),
access-dingtian.test.ts (active-level inversion). Workspace build+lint+test green
(158 server tests). Wiki: hikvision-radar, button-light-indicator + updates.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-24 11:45:22 +02:00
julian b7300ec080 fix(hik-alarm): listen on all methods + skippable source-IP guard (WSL)
Diagnosed why no camera push ever landed: (1) the route only registered
POST/GET, so a probe with another method got a generic 404 the camera
reads as "service available" while our handler never ran; (2) more
fundamentally, WSL mirrored mode REWRITES the inbound source IP to the
host's own address (10.0.10.203), so the camera's real IP (10.0.10.12)
never survives and the source-IP guard rejected every push as a mismatch.

- Register the event route on POST/GET/PUT/PATCH/DELETE/OPTIONS (HEAD comes
  with GET) so ANYTHING hitting the path reaches the handler and is recorded.
- Log + store the HTTP method of each hit; log every hit on arrival, before
  any guard, so even a rejected probe is visible immediately.
- Add per-device skipSourceIpCheck (a Setup checkbox) to bypass the
  source-IP guard where the network rewrites the source (WSL). Digest auth +
  the signed ledger remain the real guards.

Tests: hik-alarm 10 (skip-IP accept + method capture). server green;
web build green (new checkbox renderer + this field).

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-22 11:02:17 +02:00
julian 6133923094 feat(camera): Hikvision Alarm Server event-push ingress (discovery-first)
Newer Hik firmware can PUSH events to us: Event -> Smart/VCA with
"Detection Target: Human/Vehicle" + Notify Surveillance Center + Alarm
Settings -> Alarm Server makes the camera HTTP-POST an
EventNotificationAlert on each detection.

- New POST /api/devices/hikvision/:deviceId/event (routes/hikvision-alarm.ts):
  same machine-push pattern as the Dingtian Input Link — source-IP guarded
  + optional HTTP Digest, not behind the SPA cookie/CSRF.
- Discovery-first / permissive: a wildcard content-type parser accepts ANY
  body as raw bytes (event XML, multipart+JPEG, or JSON — Hik varies by
  firmware), records it verbatim as a kind:"alarm" device_event, and
  best-effort extracts eventType/target/plate/dateTime/channelID for the
  summary + a loud log line. The point is to SEE exactly what a camera
  sends before wiring it further.
- hikvision driver gains alarmPushEnabled + pushUser/pushPassword config and
  pushesToBackend:true (setup offers the backend push IP).
- NOT yet a barrier trigger / DeviceReadEvent — records only. A plate read
  is advisory, never the sole reason a barrier opens; the read-bus/ANPR
  wiring is a deliberate next step once the real payload is known.

Tests: hikvision-alarm.test.ts (6: vehicle XML summary, ANPR plate, raw
JSON, wrong-IP 404, disabled 404, unknown-device 404). server 109/109;
build+lint 14/14. Wiki: lpr-camera.md + log.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-22 10:02:35 +02:00
julian 742653aefb feat(setup): "Test ANPR" probe on ANPR-enabled cameras
Adds a bottom-of-modal "Test ANPR" button (shown only when a camera's
Plate recognition opt-in is checked) that captures a live snapshot off
the camera and runs it through the vision service, reporting the plate
read + confidence + elapsed time, or which stage failed.

- New POST /api/setup/test-anpr: builds the camera from the unsaved
  config (no DB write/device change, like /test), captures a snapshot,
  runs vision.analyze. Fail-soft like the runtime path (snapshot.ts):
  camera/vision failures are reported results, never a 500.
- Thread the existing VisionClient into setupRoutes; add an isCamera()
  type guard to @parking/devices.
- Web: testAnpr() client + AnprTestResult; button, hint, result line.
- i18n keys in sq + en (Catalog parity).

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-22 00:02:31 +02:00
julian 352c643009 test(devices): Phase 2 — ESC/POS byte stream + printer routing
Pins the device-layer bugs we kept hand-verifying, as pure byte-stream assertions
(no sockets, no hardware):

- printer-escpos.test.ts (12): CP852 codepage select; the ë→0x89 / Ë→0xD3 mapping
  and the em-dash/⚠ ASCII fallbacks (never a stray 0x3f "?"); and the Code128 MODULE
  WIDTH contract — a short ticket id at width 3, but the ~20-char out-of-window
  occurrence id at width 2 so it fits the 80mm head (width 3 overflows ~576 dots and
  the firmware silently aborts the barcode). Plus the QR-and-Code128 dual encoding and
  the Albanian stamp() format.
- printer-routing.test.ts (6): the failover order (booth printer is a fallback for
  entry tickets; a receipt never prints on the outside dispenser), rank-then-id
  tiebreak, and printWithFailover walking the order + NoPrinterAvailableError.

Wires Vitest into @parking/devices. devices 18/18 green.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-21 16:17:51 +02:00
julian 31f116a068 fix(print): center the out-of-window slip barcode again
The previous width fix also forced ALIGN_LEFT inside code128(), which moved the
slip's barcode to the left. But the no-print bug was the barcode WIDTH (too wide
to fit the head at module width 3), not the centering — at width 2 it fits and
centers fine. So code128() no longer touches alignment; the caller controls it.
The out-of-window slip block is ALIGN_CENTER, so the Code128 + QR center as they
did before, just narrow enough (width 2, ~510 dots) to actually print. The
voucher receipt barcode likewise centers as it originally did.

Verified: alignment-in-effect at the barcode = CENTER, module width = 2, QR
present; build+lint 14/14.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-21 13:52:42 +02:00
julian 663bf0e925 fix(print): out-of-window slip Code128 was too wide to print — width 2 + left-align
The slip printed the QR but NOT the Code128 barcode on the Rongta. Root cause:
the ~20-char occurrence id (SUBSESS-…) at module width 3 is ~765 dots wide —
over the 80mm head's ~576 printable dots — so the firmware silently aborts the
barcode (prints nothing). It was also emitted while ALIGN_CENTER (set for the
title) was active, which shifts the start point right and makes it overflow
even sooner. The QR, being compact, rendered fine — hence QR-only output.

code128() now takes a moduleWidth (default 3, so the shorter entry-ticket id is
unchanged) and forces ALIGN_LEFT (a wide barcode must hug the margin). The slip
passes width 2 (~510 dots — fits with quiet zones) and re-centers the QR/text
after. renderReceipt's voucher barcode re-asserts ALIGN_CENTER for the lines
that follow it.

Verified: width n=2 in the byte stream, est 510 dots; Code128 + QR both present;
build+lint 14/14.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-21 13:44:01 +02:00
julian df5caf8d87 feat(subs): scannable out-of-window slip + two-step booth flow
The advisory out-of-window slip for a subscriber had two problems:

1. Faulty character codes. It rendered via the generic text printReport,
   which has no CP852 mapping for the em dash, ellipsis, or warning sign in
   the composed strings — so they printed as "?" ("PARKIM ? JASHTE ORARIT").
   Added ASCII transliterations for that typographic punctuation in the
   ESC/POS encoder (— → -, ⚠ → !, … → ..., curly quotes/bullet), so they
   degrade to a readable glyph instead of "?".

2. Not scannable. The slip printed only "Nr: SUBSESS-…" as plain text, so
   the operator had to hand-key it. Gave the notice its own render function
   (renderWindowChargeNotice) + a printWindowChargeNotice device method that
   prints the occurrence id as a Code128 AND a QR — the same scan path as a
   transient ticket, so the operator scans it straight into the booth pay
   modal, which then quotes the combined window charge. Implemented on both
   the rongta and cashino drivers.

Also fixed the booth pay modal: "Open barrier" no longer shows by default
for a subscriber. A prepaid subscriber with nothing owed sees only a small
"assist open" reveal (the audited manual open for a faulty reader / lost
card stays available, just not the default). A subscriber owing an
out-of-window charge is now two steps — take payment first, then "Open
barrier" appears — instead of an always-on open button.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-21 13:12:05 +02:00
julian bbf61c48df fix(ticket): 11-digit IDs — fix KP-300H barcode line-overflow
The Cashino KP-300H printed entry tickets as raster garbage (solid black
bars / banding) while the Rongta printed the same byte stream fine. Root
cause: the barcode overflowed the print line, not data corruption.

A 13-digit Code128 at module width 3 is ~534 dots. The KP-300H prints 72mm
(512 usable dots at 203 dpi), so the symbol overran the line and the firmware
rendered the overflow as raster noise. The Rongta runs 80mm (576 dots) and had
just enough room — which is why only the Cashino failed. Confirmed on hardware:
plain text printed clean, the barcode was the trigger, and an 11-digit code at
width 3 (~468 dots) both fits and scans the full value at the exit reader.

- Ticket IDs reduced 13 → 11 digits (10 random + Luhn). Length is driven by
  guess-resistance (10^10 space, ~1-in-10^7 to hit a live OPEN ticket even with
  thousands parked — the booth-operator threat model), not volume.
- validateTicketCode is now length-agnostic (\d{10,14} + Luhn) so legacy
  13-digit tickets still in circulation keep validating; the id stays opaque.

Also: sendRaw now closes the print socket GRACEFULLY (end()+FIN, wait for
close) instead of write-then-destroy, which could RST mid-stream and truncate a
job. A separate latent bug found while diagnosing, fixed here.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-19 11:35:13 +02:00
julian 00f3d141b6 feat: human + relative dates; fix language/theme toggle stale-context
Dates were raw ISO on printed slips and time-only in the UI (a session from
two days ago showed just "10:48"). Make them human and day-relative. Also fix
a latent toggle bug surfaced while testing.

Dates:
- Printed tickets/receipts/subscription cards now show "19 Qershor 2026
  10:48:25" (Albanian month, 24h with seconds) instead of YYYY-MM-DD HH:MM.
  stamp() exported as formatStampSq so the shift Z-report shares it.
- Shift Z-report is now Albanian (Operatori/Nga/Deri/Para në dorë/Arka…),
  was English-only with ISO dates.
- Web sessions/logs/history show relative days: "Sot 10:48" / "Dje 17:33" /
  "17 Qershor 10:48" via formatRelativeDateTime(). Month names come from the
  i18n catalog (common.months), NOT Intl — the appliance browser's ICU lacks
  Albanian locale data and Intl silently falls back to English month names.

Toggle fix:
- The language + theme toggles read the active value from the TanStack Router
  context `user`, which is captured at route-resolution time and does not
  re-render on setUser. After one switch the highlight froze and the equality
  guard blocked switching back until a page refresh. Drive them off live state
  instead: language from i18n.language (useTranslation subscribes to
  languageChanged), theme from local useState. (Bug dated to 040c0ff.)

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-19 11:14:06 +02:00
julian d71ba82999 feat(booth): payment receipt / exit voucher — transparency slip + CP852 fixes
After a completed payment the customer always gets a transparency record:
entry time, payment time, duration parked, amount + tender. One shared
ESC/POS renderer (renderReceipt + ReceiptData in @parking/devices), two
modes: VOUCHER = those figures PLUS the scannable Code128 barcode and an
emphasised walk-back-grace line, so the one slip both proves payment and
self-exits at a distant exit reader (replaced the old barcode-only voucher);
STANDALONE = detail-only, auto-printed at payment when no voucher is issued.
Figures fold from the SIGNED ledger (latest payment event); printed on the
booth printer (failover to dispenser). Best-effort: a printer fault never
blocks the exit that already happened — the modal shows a note and offers
"Reprint receipt".

Server: booth-print.ts printPaymentReceipt() + receiptFigures(); routes
POST /api/voucher (voucher) + new POST /api/receipt (standalone/reprint).
Both ESC/POS drivers gained printReceipt(). Web: BoothPayModal auto-prints
after a non-voucher payment + reprint button; api.ts printReceipt().

CP852 fixes found on a real printout: (1) uppercase Ë was mapped to 0xEB
(that's ű) — correct byte is 0xD3; (2) Intl.NumberFormat injects a NO-BREAK
SPACE (U+00A0/U+202F) that isn't in CP852 and printed as "?" — line() now
normalises it to a plain space ("1000 Lekë"); (3) grace line wrapped
mid-word — split into two short lines.

Full build green; both receipt modes render-verified; routes live.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-18 20:46:38 +02:00
julian 3e6773a6d5 fix(devices): Cashino printer — ping-only driver (no false status) + Albanian role wording
The Cashino 80mm printer reported wrong status: it ran on the `rongta`
driver, whose readStatus() scrapes the Rongta board's /prn_stat.htm status
page — which the Cashino does not serve — yielding a bogus degraded/page-
error verdict while the printer was online and printing fine. Root cause:
the Cashino is an ESC/POS PRINT clone with no trustworthy STATUS mechanism.

Fix: extract the shared ESC/POS rendering + transport (renderTicket/
renderReport/renderSubscriptionCard/sendRaw/probe + CP852 map + code128/
qrCode) from printer-rongta into drivers/printer-escpos.ts, and add a
dedicated `cashino` driver that reuses that print path but is deliberately
NOT MonitorableDevice (no readStatus). isMonitorable() is then false, so the
device monitor falls back to healthCheck() — a plain TCP reachability ping:
reachable -> ready, unreachable -> offline, never a guessed paper/cover
state it cannot sense. Rongta driver unchanged (still scrapes its page,
still monitorable). Register + re-export cashinoDriver.

Verified at runtime (cashino registered, isMonitorable=false, no readStatus,
healthCheck->offline on unreachable) and live: /api/devices/status shows both
printers ready (lane via ping, booth via page). The live entry-dispenser at
10.0.10.9 was switched rongta->cashino in the operator DB (backed up).

Also fix the Albanian device-role chip wording, which read wrong as a
"{category} {role}" label: access mixed "i përzier" -> "hyrje/dalje"
(it means a barrier spanning both directions); printer lane "korsia" ->
"në korsi"; booth "kabina" -> "në kabinë". English tidied to match
(mixed->entry/exit, lane->at lane, booth->at booth).

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-18 20:00:42 +02:00
julian bba988c4e8 feat(subscription): QR credentials — operator-choose (QR-only now), auto-generate, multi-month, printed card
Builds out subscription credentials on top of the rename.

- Operator chooses the credential type; only QR is live (RFID shown disabled
  "soon"). Backend/schema keep accepting both — re-enabling RFID is UI-only.
- QR codes are AUTO-GENERATED server-side (SUB-<base32>, crypto-random,
  globally-unique-checked) — the customer/operator never picks the value.
  RF stays operator-entered (the physical card id). Reader output decided =
  TCP/IP full string (Wiegand-numeric fallback noted).
- Multi-month: form takes a `months` count → server sets validTo =
  validFrom + N months (day-clamp); one record/one window; total = N×monthly.
- The QR card is PRINTED so the operator can hand it over: real ESC/POS 2D QR
  (GS ( k) added to the Rongta driver (printSubscriptionCard); auto-print on
  create (best-effort — never fails the create; returns {printed,printError})
  + reprint via POST /api/subscriptions/:id/print and a "Print code" button.

Verified via buildServer+inject incl. a TCP capture of the on-wire QR bytes
(autogen+uniqueness, Jan31+3mo→Apr30, auto-print, GS ( k QR with embedded
code, reprint, no-QR→409). Updated wiki (subscription, rongta-printer). No
migration.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-18 14:48:38 +02:00
julian 727c62da90 ticket: site metadata header + scannable Albanian ticket; widen barcode
- site_config gains optional park identity (park_name, operator_name, nius,
  address, phone, email); additive Drizzle migration 0001. GET/PUT
  /api/site-config read/write the full config (PUT partial patch, admin only);
  SiteSettings + SetupWizard expose the fields.
- renderTicket() prints an Albanian header sourced from site_config, the
  all-numeric 13-digit ticket id (12 random + Luhn) as Code128, large digits,
  and a lost-ticket footer. CP852 codepage so ë/ç render.
- Widen the Code128 module width 2->3 and height 80->100 dots so the
  short-range "Simple" QR/barcode reader decodes reliably (was barely reading
  at module width 2 on the 80mm head).

See wiki/concepts/site-metadata.md and ticket-encoding.md.
2026-06-17 12:17:21 +02:00
julian 1efa77bf56 devices: pool-of-spaces model — drop lane, per-relay direction
A parking lot is one pool of spaces with a flexible set of entry/exit
points — no "lane". Direction is a property of each RELAY inside an access
controller; readers/cameras bind to a controller relay and inherit it.

Schema:
- drop `lane` from ledger_events, device_events, sessions
- rename lane_devices -> devices (no lane/direction columns)
- access config.relays=[{relay,direction,button?}]; reader/camera
  config.controllerId+relay binding
- fresh 0000_baseline migration (history reset; dev data was throwaway)

Signed ledger:
- remove `lane` from canonicalize(); bump signer keyId sw-hmac-v1 -> v2
  (v1 events won't verify under v2 — intentional, gated per-event by keyId)

Server:
- new device-resolve.ts (replaces lane-map.ts): relayForButton,
  relayForDevice, firstRelayByDirection, devicesByDirection
- entry-flow: button terminal -> its relay; exit/permit: reader's bound
  relay; dispatcher resolves the bound relay + inherited direction
- camera snapshots fire by direction site-wide, async, never block open
- DeviceConfig widened to nested JSON for relays[]

Web:
- wizard: no lane selector; add controllers (relay map + entry-button
  terminal) first, then bind readers/cameras/printers to a controller relay

Wiki: new entry-exit-points.md (replaces lane-direction); reworked
entry-exit-readers, parking-session, first-run-setup, device-registry,
append-only-event-chain, device-events; removed stale lane/LaneMap mentions.
2026-06-16 20:29:38 +02:00
julian 5705098054 devices: stub-access driver (bench-test flows without a relay)
A live QR scan reached the app but rejected: 'reader not on an access-equipped
lane' — the dispatcher requires an access device on the reader's lane. Add a
no-op stub-access driver (access category, no config) whose pulseOpen only logs
and does no device I/O, so the QR->permit->accept flow (incl. the beep) can be
tested without the Dingtian relay connected. Not for production; registered in
the catalog.
2026-06-16 12:50:05 +02:00
julian 68d61f2d99 qr-reader: gee-qr-reader driver — assign in wizard, resolve lane by serial
The QR reader is a push device and the setup wizard assigns random-UUID ids, so
'id = serial' can't be set via the UI. Add a dedicated gee-qr-reader driver
(reader category) with a single 'serial' config field; the admin assigns it
normally and enters the device's serial (its cjihao).

The QR endpoint now resolves the lane by matching lane_devices.config.serial to
the scan's cjihao (instead of row id == cjihao), so no DB hand-editing. An
unassigned serial resolves to no lane -> status:0, gracefully.

Verified via inject through the real /api/setup/assign: assign {serial:
H05M2AFA} -> .jsp scan with a matching permit QR -> status:1 (accept) + open;
re-scan -> permit exit; unknown card -> status:0; unassigned serial -> status:0.
2026-06-16 12:36:58 +02:00
julian 644bfa1462 server+web: shifts — open/close + signed Z-report (manned mode)
A shift is two signed ledger events, no mutable table: new shift_open event
type + existing shift_z_report. The operator is the logged-in user (carried in
event identity); a shift is open iff their latest shift event is a shift_open.

ShiftService: close sums payment events in [start,end] by tender (cash/card, by
payment time), appends the signed shift_z_report (totals/counts/window), and
prints via a new generic PrinterDevice.printReport(title, lines) (Rongta ESC/POS
text) to a booth-receipt printer. Print is best-effort — a failed print does not
undo the signed close.

Routes (cashier/operator/admin): GET /api/shift/current, POST /api/shift/open
(409 if open), POST /api/shift/close (409 if none). Web ShiftControl in the
shell (non-readonly): Start/End + Z-report totals.

Verified: open -> double-open 409 -> payments (cash+card; one outside the window
excluded) -> close totals correct + signed + printed -> close-again 409 ->
re-open ok; readonly 403; verifyChain ok.
2026-06-16 08:01:59 +02:00
julian fa65b2df86 Real Hikvision/Dahua camera driver; gate Backend-push-IP on capability
Replace the camera stub with HttpCamera: Hikvision ISAPI and Dahua CGI
snapshots over client-side HTTP Digest (new drivers/http-digest.ts).
healthCheck() now pulls a real frame instead of returning ready/stub.
Snapshot carries bytes (driver fetches); storage/imageRef is the caller's
job, keeping the adapter free of storage deps.

Fix the cosmetic Backend-push-IP field: add pushesToBackend to DeviceDriver
(only Dingtian sets it), expose as pushCapable in the catalog, and gate the
wizard's backend-IP fetch + field on it so pull-only devices hide it.

Verified on hardware (Hikvision 10.0.10.121): healthCheck ready,
captureSnapshot returns a valid JPEG.
2026-06-15 16:17:49 +02:00
julian f5fd61984a Dingtian web password: set the admin's chosen password, verified
Fix two bugs found running the real assign flow: the saved web password
didn't match the device (login stayed admin/admin), and the UDP2 warning
never reached the admin.

Web password:
- Split the conflated field into webPassword (the DESIRED login; blank ->
  auto-generate) and webPasswordCurrent (the device's EXISTING password used
  as the old cred, default admin). Before, an admin typing a desired password
  made harden send it as the old cred -> rotation failed -> but the DB still
  saved the typed value, so it claimed a password the device never accepted.
- harden() now rotates current -> desired, VERIFIES by re-authenticating with
  the new password, and only returns secrets.webPassword on success (else a
  warning, nothing saved). Stores webPasswordCurrent for future re-runs.
- assign strips the typed webPassword/webPasswordCurrent and persists only the
  verified secret -- the DB never claims an unapplied password.

Warnings to the UI:
- assignDevice returns warnings[]; SetupWizard shows them in an amber
  "saved, but action needed" banner per category. This is how the admin learns
  the firmware wouldn't disable UDP2 (finish in the device web UI).

Verified on hardware: after harden the device rejects admin/admin and accepts
the chosen password; the UDP2 warning surfaces.
2026-06-15 12:26:34 +02:00
julian 7db5cfa0e4 Dingtian: close password-less string-protocol relay-fire hole
The string protocol (UDP 60001) has no password field but can fire relays
("11" = relay 1 on), bypassing relay_pw entirely. Proven on hardware: an
unauthenticated packet opened a relay. harden() had left it enabled "for
status reads".

- #status() now reads via the authenticated binary command (relay cmd 0x00)
  instead of the string protocol, so the string protocol is no longer needed.
- harden() disables the string protocol (udp2.p=255). BEST-EFFORT: firmware
  V3.6J's config API silently refuses to disable udp2 (the device web UI can),
  so it's not part of the blocking verify -- harden() re-checks and returns a
  warning instead of throwing. After a web-UI disable, the attack is dead and
  binary control/status still work (verified on hardware).
- HardenResult gains an optional `warnings[]`; the assign route surfaces them
  to the admin and logs them.
- Corrected the false comment claiming relay_pw stops an attacker (it is
  defence-in-depth on plaintext UDP, not a boundary).
- Thread localAddress through the driver's UDP/HTTP calls so a multi-homed
  host sources device traffic from the device-facing NIC.
- Device web login (webUser/webPassword) is no longer redacted from setup
  state -- it's an operational credential for the admin-only device area;
  pushPassword/relayPassword stay machine-only.

Wiki: document the vuln + fix, the firmware caveat, and the out-of-band
actuation gap (the log captures host actions only; reconciliation vs. an
independent witness is the real control and is not yet built).
2026-06-15 11:29:55 +02:00
julian b2a0471b08 Rongta 80mm printer: driver, role-based failover, live status monitoring
Add the rongta PrinterDevice driver (ESC/POS over raw TCP 9100) and the
device-agnostic pieces around it:

- Roles + failover: each printer declares a role (entry-dispenser/booth-
  receipt) and failoverRank; printer-routing.ts picks the best healthy printer
  and falls back outside->booth for entry tickets (never the reverse).
- Live status: MonitorableDevice.readStatus()/PrinterStatus capability. The
  Rongta driver scrapes the device's own /prn_stat.htm (Cover/Cutter/Paper
  End/Near End/Off-Line) rather than hand-decoding DLE EOT, whose reply bytes
  on this clone don't match the canonical ESC/POS bit layout (verified on
  hardware) -- avoids a false-healthy. Maps to ready/degraded/offline, fail
  safe on an unreachable or unexpected page.
- Server PrinterMonitor polls enabled printers (PRINTER_POLL_MS, default 5s),
  caches latest, emits "printer-status" on change. Exposed via
  GET /api/printers/status and an SSE stream for the booth UI.

Verified against 10.0.10.6: ready when healthy, offline when unreachable
(no throw), bus emits on change and suppresses unchanged reads.

Wiki: new rongta-printer entity, printer-roles-failover and
printer-status-monitoring concepts; BOM/index/log updated.
2026-06-14 20:26:45 +02:00
julian 2a86e578a8 Dingtian harden(): rotate the admin/admin web login (cosmetic)
harden() now rotates the device's default admin/admin web-UI login via
GET /userset.cgi?<old>&<old>&<new>&<new>& (best-effort: a failure logs
and doesn't fail the assign). The new password is stored back in config
(webUser/webPassword) so a re-run can rotate again, and is stripped from
the assign response like the push secret.

Documented the load-bearing caveat: this device's CGI API is fully
UNAUTHENTICATED — config read/write, relay fire, and userset.cgi itself
all return 200 with no credentials (verified on hardware). admin/admin
gates only the browser UI, and there's no inbound-auth setting (only
session_en, which bricks the read API). So the rotation is defence-in-
depth for the UI, NOT a boundary; the signed event log remains the real
anti-fraud guarantee. Verified rotation end-to-end on 10.0.10.5
(success &0&, wrong-old-pw &2&); device left at admin/admin.
2026-06-14 19:00:42 +02:00
julian 7fd407ac82 Harden Dingtian: authenticated binary relay + disable unused channels
Lock down the relay device for the flat (no-VLAN) network.

Relay control:
- pulseOpen/setRelay now use the Dingtian BINARY protocol (:60000) with a
  relay password — the only relay option with auth (string :60001 has none, and
  is kept only for the read-only status query). Frame verified on hardware.

HardenableDevice capability (driver harden()):
- set a random relay_pw (1-9999); disable unused channels (rs485/can/tcp x2/mqtt
  -> p:255), keeping UDP1 binary (control) + UDP2 string (status).
- write-verified (device reboots on apply).

Assign/Save flow now does: fix preconditions -> harden -> set up input push;
the relay password is stored in lane_devices so the runtime device can command
the relay.

DELIBERATELY NOT touching the device's HTTP CGI session check (session_en):
enabling it on this firmware breaks the config-READ API (ECONNRESET) and locked
the backend out — required a factory reset to recover. The open CGI API is
accepted as flat-network reality; the signed event log is the real guarantee.

Verified end to end on hardware: assign hardens + configures the device, config
API stays reachable, pulseOpen with the stored password fires the relay, without
it is rejected. wiki: device-input-flow + dingtian-relay updated.
2026-06-14 18:34:35 +02:00
julian 3294f188dd Dingtian input push: HTTP Digest auth + auto-config on assign
Secure the device→backend input push, and configure it automatically when the
admin assigns the device (no manual URL/secret entry).

Auth — HTTP Digest (chosen by hardware testing: the device can't push to a
self-signed HTTPS backend, but does Digest correctly; a URL token is sniffable/
logged):
- digest-auth.ts: MD5 qop=auth challenge/verify, single-use nonces (replay
  resistance). Password never crosses the wire.
- push route: Digest + source-IP allowlist; per-device pushUser/pushPassword from
  lane_devices. Still not behind the SPA cookie/CSRF auth (machine call). The
  signed event log remains the real anti-fraud guarantee.

Auto-config on assign:
- setup assign: for push-capable devices, generate Digest creds, call
  configureInputPush to write them + the push URLs to the device, store the creds
  (password not echoed back). net.ts derives the backend IP on the device's
  subnet (BACKEND_HOST_IP override).
- driver configureInputPush sets auth=2 + creds; PushConfig carries the creds.
- removed the earlier URL-token approach.

Two hard-won device-write bugs fixed in the driver:
- configApi now sets an explicit Content-Length — the device silently ignores
  chunked request bodies (Node's default without Content-Length), so every config
  write looked successful ({"status":0}) but did nothing. This was the root cause
  of the session's "writes don't apply" mystery.
- #writeConfig polls until the change is verified, retrying (the device reboots on
  apply; back-to-back writes were lost). The `pass` field caps at 31 chars, so the
  generated password is 24 hex chars.

Verified on hardware: assign auto-configures the device; all 4 inputs then push
with Digest auth, zero failures. wiki/device-input-flow updated.
2026-06-14 16:39:08 +02:00
julian 23919164ee Dingtian input HTTP-push to backend (no polling)
The device pushes button events to the backend via its Input Link URL feature;
the backend decides. No polling — the chosen entry architecture.

packages/devices:
- dingtian driver: configureInputPush() writes the device's input_link_url
  config (per-input server/port/path, en=1, active-LOW, plain HTTP) so each
  input HTTP-GETs the backend on press/release. Extracted #readConfig/#writeConfig
  (with the required command:setconfig injection + post-write reset tolerance).

apps/server:
- routes/devices.ts: public GET/POST
  /api/devices/dingtian/:deviceId/input/:n/{on,off} — translates a device push
  into an internal device event. Not behind cookie/CSRF (machine call from the
  device); trust comes from the signed event log, not this request.
- device-events.ts: internal EventEmitter bus so the entry flow subscribes to
  input events without coupling to HTTP. Wired into the server.

Verified on hardware: configured the device, then real presses on all 4 inputs
pushed to the backend (input N on+off, source = device IP). No polling.

wiki: device-input-flow concept (path + trust model for the flat/no-VLAN
network); dingtian-relay updated; index + log.
2026-06-14 15:10:50 +02:00
julian 355026dcf7 Remove UHPPOTE/ZKTeco; Dingtian is the only access driver
Neither UHPPOTE nor ZKTeco is used — the Dingtian relay controller was chosen
and verified. Remove their code and re-scope the wiki.

Code:
- delete access-uhppote.ts, uhppoted.d.ts, access.ts (zkteco/esp32-relay stubs),
  and the three uhppote-*.mjs hardware test scripts.
- remove the `uhppoted` npm dependency from @parking/devices and @parking/server.
- unregister uhppote/zkteco/esp32-relay from the driver registry; drop their
  exports. Catalog access drivers = dingtian only. Build green (5/5).
- refresh now-stale example comments (registry/interfaces/setup/api) to use
  current examples; keep the two "UHPPOTE blocker" references that explain why
  the precondition capability exists.

Wiki (kept pages, re-scoped):
- uhppote-controller, zkteco-controller -> rejected/historical with callouts;
  uhppote-vs-esp32 -> historical (detection-vs-prevention lens still useful).
- re-point all "current device" framing (standing-decisions, bom, overview,
  open-questions, device-registry, device-discovery, index) to dingtian-relay.
- transferable concepts (network-isolation, event-log-ingestion, barrier-not-a-
  door, threat-model) untouched. Raw source immutable. Links lint clean.
2026-06-14 14:28:52 +02:00
julian 1b55e2034d Dingtian relay driver — resolves the ticket-first entry blocker
The Dingtian board's inputs are independent of its relays (configurable), so a
button on an input can report to the host WITHOUT auto-firing a relay — solving
the access-controller-button-flow blocker the UHPPOTE/ZKTeco couldn't.

packages/devices:
- access-dingtian.ts: `dingtian` access driver implementing AccessControlDevice
  (relay pulse/latch via UDP string protocol :60001), InputDevice (read inputs +
  poll-based press/release events, active-LOW), and the new PreconditionDevice.
- PreconditionDevice capability on the interface: a device can report config it
  requires for parking and optionally fix it. Dingtian checks input_link_relay
  via the HTTP config API and can disable it.
- httpPort config field — the web/config API port is separate from UDP control
  (this unit uses 8080, not the default 80).
- Register dingtian; export driver objects from the package.

Verified on real hardware (DT-R004 @ 10.0.10.172): status read, relay pulse,
input events; disabled input_link_relay via the driver, then confirmed pressing
inputs fires NO relay (0000) — host-in-the-loop entry works.

Config-write gotcha recorded: config_set.cgi requires "command":"setconfig"
injected after "status" (GET omits it) or the POST silently no-ops.

apps/server/scripts/dingtian-test.mjs: status / watch / pulse hardware test.
wiki: dingtian-relay verified; button-flow marked RESOLVED; index + log.
2026-06-14 14:15:00 +02:00
julian 77606da2c9 UHPPOTE hardware bring-up + entry-flow blocker
Brought up the real UHPPOTE controller (serial 225088491, fw 09120) end to end
and recorded a procurement-level blocker.

Verified on hardware:
- discovery (LAN scan), host-commanded openDoor on doors 1 & 2 (physically
  actuated; reason="remote open door"), and live button capture
  (reason="push button ok").

Driver/networking fixes (packages/devices/src/drivers/access-uhppote.ts):
- broadcast to subnet-directed address (lib doesn't enable SO_BROADCAST for the
  global 255.255.255.255 -> EACCES);
- Config broadcast must match the target's subnet for unicast reply routing
  (fixes the health-check timeout: 5s -> 24ms ready);
- discover across all local subnets, dedupe by serial;
- serialize all controller I/O (concurrent calls collided on UDP :60001).

Server/UX:
- load .env via node --env-file-if-exists (vars weren't being read before);
- SETUP_AUTH_BYPASS hardened: env-gated, dev + loopback only, fails closed
  otherwise; surfaced as catalog.authBypass so the wizard drops the token field;
- .env.example documents all vars; inline favicon stops a 404.
- apps/server/scripts/: uhppote-listen (live events, restores prior listener)
  and uhppote-relay (guarded door-open test).

BLOCKER (wiki/decisions/access-controller-button-flow.md): the controller's
push-button input auto-opens the relay in firmware with no report-without-open
mode, so ticket-first entry (button -> print -> open, fail-closed) is impossible
as wired. UHPPOTE can't do it on that input; ZKTeco *might* via a programmable
aux input + PULL SDK but that's unverified and needs a new driver. Entry-lane
hardware decision paused to focus on the business side.

wiki: access-controller-button-flow (blocker), zkteco-controller (stub +
assessment), uhppote-controller callout, index + log.
2026-06-14 10:29:43 +02:00
julian a0e0fd9118 Add device discovery (UHPPOTE LAN scan) to setup
UHPPOTE controllers self-announce via UDP broadcast, but the frontend had no way
to find them — the admin had to type the serial blind. Add a generic discovery
capability and surface it in the setup wizard.

packages/devices:
- DiscoverableDriver capability + DiscoveredDevice type + isDiscoverable() guard
  on the registry (optional, so any driver can opt in).
- uhppote driver implements discover() via uhppoted getDevices (UDP broadcast),
  mapping each controller's serial/IP/firmware into a DiscoveredDevice; extract
  shared buildCtx().

apps/server:
- GET /api/setup/discover/:driverId (admin-only): runs discover() and
  health-checks each found device so reachability shows before assigning.
- catalog now returns a `discoverable` driver-id list.

apps/web:
- SetupWizard "Scan for controllers" button for discoverable drivers; lists found
  devices with health badges; selecting one auto-fills serial + host. api client
  gains discoverDevices().

wiki: new device-discovery concept; cross-link from registry/setup/uhppote;
note the broadcast-permission (EACCES) deployment caveat; index + log.

Verified: catalog flags uhppote discoverable; discover runs and fails gracefully
without hardware; non-discoverable driver -> 400; missing token -> 401.
2026-06-14 08:21:27 +02:00
julian 7438c0bdc2 Add real UHPPOTE access driver via official uhppoted lib
Researched Node options for the UHPPOTE controller and chose the official
`uhppoted` npm package (MIT, actively maintained, single trivial dep). Its API
covers the full design: openDoor, getStatus, the event-log set (getEvent,
getEventIndex, setEventIndex, recordSpecialEvents), and setListener/listen.
Rejected alternatives: raw-dgram DIY, node-red-contrib-uhppoted, Go sidecar.

- packages/devices: add uhppoted@0.9.0; new `uhppote` access driver implementing
  AccessControlDevice (pulseOpen -> openDoor intent-only; healthCheck/getDoorStatus
  -> getStatus). Registered in the catalog alongside zkteco/esp32-relay.
- Local ambient types (uhppoted ships none); CJS interop via default-import +
  destructure under NodeNext.
- Config fields: controller serial (required), optional host/protocol (udp|tcp),
  doors, timeout.

Security/safety unchanged: unauthenticated UDP -> isolated VLAN assumed; relay
is intent-only ("a barrier is not a door").

wiki: record the library choice on uhppote-controller + log entry.

Verified: builds; `uhppote` shows in the catalog with correct fields;
instantiates and degrades to "offline" gracefully without hardware (on-VLAN
test pending).
2026-06-14 08:12:27 +02:00
julian 72ba4099ea Device-agnostic driver registry + first-run setup
Make the device-adapter pattern selectable so the admin chooses hardware at
install — per lane, from a catalog of supported drivers. Adding a device =
registering one more driver; no business-logic change.

packages/devices:
- interfaces.ts: AccessControlDevice / ReaderDevice / CameraDevice / PrinterDevice
  (adds CameraDevice for entry/exit snapshot-on-event; access relay stays
  intent-only per "a barrier is not a door").
- registry.ts: driver catalog with per-driver config fields + factory, config
  validation, and a catalog payload for the setup UI.
- drivers/: stub adapters — access (zkteco, esp32-relay), reader (wiegand,
  tcp-ip), camera (hikvision, dahua). Real vendor protocols TBD.

packages/db:
- lane_devices + setup_state tables (migration 0001); re-export query helpers.

apps/server:
- routes/setup.ts: GET /api/setup/catalog (public schema), and admin-only
  /assign, /state, /complete with registry validation before persisting.
- extract auth.ts (requireJwtSecret, requireRole, JWT type aug).

apps/web:
- SetupWizard scaffold + api client: pick a driver per category for a lane,
  render its config fields.

wiki: device-registry + first-run-setup concept pages; cross-link from
device-adapter-pattern; index + log updated.

Verified: full turbo build (5/5); catalog lists all drivers; admin assign
persists; missing-config and no-token requests are rejected.
2026-06-14 07:59:46 +02:00
julian bfe64032d8 Initial scaffold: Turborepo monorepo + design wiki
Turborepo (pnpm workspaces) with all dependencies pinned to latest
mutually-compatible versions: turbo 2.9, TypeScript 6, Fastify 5,
React 19, Vite 8, better-sqlite3 12 + Drizzle ORM 0.45.

Layout:
- apps/server   Fastify backend (local JWT auth + role guard, /health)
- apps/web      React 19 + Vite 8 operator SPA
- packages/db   Drizzle schema on SQLite/WAL; append-only events + users
- packages/devices  reader/printer/relay adapter interfaces (intent-only relay)
- packages/shared   shared domain types

Architecture constraints from the design wiki are encoded in the scaffold:
append-only hash-chained + signed event log, device-agnostic adapters,
"a barrier is not a door" (relay expresses intent only), fully-local
offline-first auth.

wiki/ is an LLM-maintained Obsidian knowledge base (28 pages) ingested
from the architecture & design notes, with its own maintenance schema.

Verified: pnpm install, full turbo build (5/5), server boots and serves
/health, drizzle-kit generates the initial migration.
2026-06-14 00:34:11 +02:00