--- type: decision tags: [parking, decision, devices, transport] sources: [] updated: 2026-11-23 status: settled --- # Transport for the Relay Controller: HTTP/UDP now, MQTT parked **Decision (2026-06-15): use direct HTTP + UDP for the [[dingtian-relay]] controller now. MQTT is deliberately skipped, but kept on the radar** for when the system scales. ## Options the device supports The Dingtian relay board speaks several protocols: Dingtian string (UDP/TCP), Dingtian binary (UDP, optional multicast/password), **HTTP CGI**, **HTTP input-link push** (`input_link_url`), **Modbus** (RTU/TCP/ASCII), and **MQTT**. ## Why not MQTT (yet) - **A broker is new infrastructure** on a deliberately **single-purpose hardened appliance** ([[disk-os-hardening]]) — another service to install, secure, supervise, and keep alive. - **Extra failure mode on the critical path.** Today host→UDP→relay. MQTT inserts a broker on both control and event paths; if it stalls, the lane stalls — and there are 3 processes to debug, not 2. - **Doesn't fit [[offline-first]] for this scale.** MQTT earns its keep with *many* devices/consumers and intermittent links. Here it's **one host + a few devices on one isolated LAN, metres apart** — request/response control + a single input event, no fleet. - **The device's MQTT input publish is periodic** ("default every 30 s"), so it's not even a clean on-press event without relying on unverified on-change behaviour. ## Why HTTP/UDP fits - **Relay control:** direct **UDP string protocol** (port 60001) — `11`=relay1 on, `21`=off, `T1`=toggle, `11*`=jog/pulse. No deps, no broker. - **Input/button events:** the device's **`input_link_url`** can **HTTP POST to the host backend when an input fires** — real push, device calls our existing Fastify server directly, no broker. (Polling `00` status over UDP every ~50 ms is the self-contained fallback.) - Fewest moving parts; matches the local same-origin model already in use. ## When to revisit MQTT If the system grows to **many lanes / many controllers**, or multiple subsystems (LPR, payment, signage) all need to share events, a broker becomes a worthwhile central event bus. That aligns with the [[autonomous-direction|unmanned]] roadmap at multi-lane scale — re-evaluate then. Until then, direct HTTP/UDP wins on simplicity and reliability. ## The condition is met (2026-11-23) The user decided a bus between the vision side, the server and the booth screen, as part of an event-driven refactor of the repository ([[event-driven-refactor]]). That is the case named above: several subsystems sharing events. Which bus is not decided, and nothing here says the relay controller moves onto it. The objections above (new infrastructure on the appliance, one more thing on the path that opens the barrier) still want an answer in that plan.