--- type: entity tags: [parking, hardware, barrier, relay, wiring] sources: [] updated: 2026-11-14 --- # ZKTeco CMP200 Barrier Gate The boom barrier on hand. Its mainboard (silkscreen on our unit: `TT-DZ-200504E-A1`) drives an **AC capacitor-start motor** through on-board relays; limits are Hall switches. Mains 110/220 V AC, 100 W rated. Not to be confused with the [[zkteco-controller]] (access panel, rejected). Web research 2026-11-14. Sources: ZKTeco CMP200 user manual v1.0 (2019) and v1.2 (March 2022), wiring diagrams read from the PDFs: , . No public document names the `TT-DZ-200504E-A1` board, but a photo of our unit (user, 2026-11-14) matches the **v1.2** layout: `MOTOR UP/COM/DOWN`, `COM/RED/GREEN`, `L/N/E`, `O.LM OUT`, `C.LM OUT`, `STOP/DOWN/UP/STUDY` keys, status LEDs, and a 2x8 socket marked `RS485`. MCU is an **STC 15W408AS** (8051 family); on-board transformer 220 V to 12 V / 600 mA; PCB date code 230602. The labels of the low-voltage terminals sit under the plug-in connectors and were not visible — pull the plugs to confirm them against the table. ## Terminal map (manual) | Terminal | Function | Signal | | --- | --- | --- | | `G` / `STOP` / `DOWN` / `UP` | "Line-controlled interface": wired open/close/stop | dry contact, short to `G` | | `G` / `DET` | vehicle (loop) detector | dry contact to `G` | | `G` / `PHO` | infrared / "crash proof" sensor | dry contact to `G` | | `CAR` (v1.2 only) | "count input" | dry contact to `G`; behaviour undocumented | | `RS485 B / A / G` (v1.2 only) | "communication module" | see below | | `+12V` / `G`, `+5V` / `G` | auxiliary supply | 12 V total under 100 mA | | `O.LM OUT`, `C.LM OUT` | open-limit and close-limit relay outputs | volt-free NO/COM/NC each | | `G` / `C.LM` / `O.LM` | external limit junction | — | | `MOTOR UP/COM/DOWN`, `LAMP COM/RED/GREEN`, `L/N/E` | motor, AC traffic lamp, mains | **mains voltage** | The v1.0 board has no RS485 and no `CAR`. The 4-pin `REMOTE` header takes the 433 MHz receiver. ## Behaviour the manual states - `UP` during a fall reverses to rising at once. `DOWN` during a rise is ignored. `STOP` halts. - `PHO` shorted during a fall: reverse to open, then **stay open**. - `DET` shorted during a fall: reverse to open, then **close automatically** when released. `DET` shorted while open or rising: the boom **falls by itself** once the detector clears. So `DET` is both anti-smash and auto-close-after-passage, done in the barrier's own firmware. - Timeout protection stops the motor if a travel exceeds the rise/fall time. - No menu, no parameters, no auto-close timer are documented. Power-loss behaviour is not stated beyond "manual release motor" — the boom does not lift by itself. ## Driving it from the [[dingtian-relay]] **Relay contact, not RS485.** ZKTeco's own integration drawings (LPR camera, inBio260) wire a relay `COM → G` and `NO → UP`. That is exactly our `pulseOpen`: one Dingtian relay, `COM` to `G`, `NO` to `UP`, jogged. It expresses intent only and never times a close ([[barrier-not-a-door]]). - **Closing** normally comes from the loop/radar on `DET`, in barrier firmware. Without a vehicle tripping `DET` the boom stays up — the abandoned-entry free pass of [[passage-confirmation]]. - **Host close (only under [[passage-confirmation]]'s conditions):** a second relay on `DOWN`, interlocked in series so it is dead while the open relay is active — relay 1 `COM → G`, `NO → UP`, `NC →` relay 2 `COM`; relay 2 `NO → DOWN`. Never one relay with `NC → DOWN` (a permanent close command; closes on controller power loss). Per the manual a `DET` or `PHO` contact reverses a falling boom, so the close is not blind **if a detector is fitted** — to be proven on the unit (test plan steps 2–3 there) before any use. - **Status back to the host:** `O.LM OUT` and `C.LM OUT` are volt-free contacts, so they can go straight onto two Dingtian inputs (contact to GND, like the button). That gives the host a real "boom reached open / closed" signal for [[device-status-monitoring]] and for the anomaly "boom opened with no signed host command" ([[threat-model]]). - **Sharing a detector:** a radar/loop with one dry contact cannot feed both `DET` and a Dingtian input directly (two different supplies on one contact). Use a detector with two relay outputs or an interposing relay. - Keep the low-voltage terminals apart from the mains block on the same board edge. **RS485 — not a usable path today.** 1. The barrier's RS485 protocol is **undocumented**. The manual labels the terminals and a plug-in "RS485 communication module" header and says nothing else: no baud, no address, no frames. On our board the **socket is empty — no module fitted**, so the `B/A/G` terminals have no transceiver behind them and are dead as shipped. Manuals for similar Chinese `DZ`-family boards show a 4-byte, 9600 bps, XOR-checksum frame, but nothing ties that to this board — unverified. 2. The Dingtian's RS485 port is an **inbound control channel** (Modbus-RTU / Dingtian string: a master commands the Dingtian). Stock firmware is not documented as an RS485 master or an Ethernet-to-RS485 bridge, and our `harden()` disables that channel. `(unsourced beyond the programming manual's protocol list — check the vendor manual before relying on either way)` 3. A serial "open" command would also be an unauthenticated open path on a wire in the lane cabinet — worse than the password-carrying relay frame we already have. ## Open - Pull the low-voltage plugs and read the silkscreen under them (`G DET CAR +12V G +5V G C.LM O.LM` and `G STOP DOWN UP / B A G / G PHO` expected). - What `CAR` does (probably queues several opens for a convoy) — test on the bench. - Fail-state: on power loss the boom holds position, so "exit fails open" ([[fail-state-safety]]) needs the manual release or a UPS, not this board.