--- type: source tags: [parking, hardware, readers, qr, dingtian, protocol, linux, tooling] sources: [dingtian-qr-linux-tool] updated: 2026-10-08 --- # Source: Dingtian QR reader — Linux configuration tool + reversed UDP protocol `raw/dingtian_qr_linux/` (`README.md`, `PROTOCOL.md`, `dingtian_qr.py`; October 2026). A reverse engineering of `QRCode_v1_6_5.exe` ([[qrcode-sdk]]) — static analysis of the Qt binary plus captures against the bench reader `HC002721` and a fake reader — and a dependency-free Python 3 replacement for the Windows tool. The script is copied to **`scripts/dingtian_qr.py`** for use on booths. Entity: [[dingtian-dt008-reader]]; runbook: [[site-device-installation]] §2. ## Why it matters Until now a DT-008's settings (IP, server target, output type, prefixes, card format) could only be read or changed with the vendor's Windows exe on a laptop plugged into the device VLAN. The exe's "Search device" / "Get parameter" / "Set" are a small binary **UDP** protocol; `get` and `set` are **unicast**, so they run from the booth itself over SSH/Netbird. The 2026-10-08 park-2 enrolment failure ([[site-device-installation]] §2 trap) was diagnosed in one command this way instead of a site visit. ## Protocol (PROTOCOL.md §2–4) - Frame: `'XXXX'` + id u32 + cmd u32 + len u32 + checksum byte (`0xFF − Σpayload`) + payload; all little-endian. Even cmd = request, reply = cmd+1. - **Quirk:** the exe sends header and payload as **two datagrams**; a single-datagram frame is silently ignored by the reader. The script mimics this. - Ports: reader listens on **24680/udp** (unicast: 0 firmware info → 64 B, 30 get params → 720 B struct, every write) and **24582/udp** (broadcast: 2 search → 3 with a 96 B DeviceInfo, 32 set-network matched by serial). Replies come from arbitrary source ports — a host firewall must allow inbound UDP to the tool's socket. - Writes: one small command per field group (6 output type, 8 card input format, 10 enter/ newline, 38 serial+QR format, 12/14 QR prefix/suffix, 44 card output+prefix/suffix, 28 Wiegand pulses; 40 fill light, 18 work mode, 16 restart interval, 22 buzzer). Ack = cmd+1 with one status byte (0 applied immediately, 1 rejected). The exe's Format Set button sends 6, 8, 10, 38, 12, 14, 44, 28 back to back; External Set sends 40, 18, 16, 22; `set` reproduces whichever group owns the changed field, after reading the struct so untouched fields are re-sent as-is. - Enumerations on the wire: output type 1 USB keyboard, 2 USB serial, **3 HTTP**, 4 MQTT, 5 RS232, 6 WG26, 7 WG34, 8 RS485, 9 AC Output, 10 TCP; card input 1 6H, 2 8H, 3 8H10D, 4 6H10D, 5 2H3D+4H5D; HTTP language 0 PHP, 1 JSP, 2 C#, 3 ASP, 4 CGI. - IPv4 fields are little-endian u32 (bytes of `inet_aton` reversed). - **DHCP is never transmitted** by the exe (its set-network code overwrites the DHCP word with the serial) — the combobox has no effect; the script cannot write it either. - Not understood: Params `0x1f4` and the reserved area `0x050–0x197` (probably MQTT/TCP settings). **Symbologies are not in this protocol** (the exe has no such field) — the phantom-read fix in [[dingtian-dt008-reader]] still has no known configuration path. ## Verification status - By the author: search/info/get and the ack format captured from the real reader; the write payloads matched against the exe talking to a fake reader; commands 18, 22, 40 proven on the real reader by diffing the struct. - **Ours, 2026-10-08, bench `HC002721` @ `10.0.10.12`:** `set --output-type 6` then `--output-type 3` — all eight Format commands acked with status 0, the diff of the 720 B struct was exactly byte `0x198` (3 → 6 → 3), final struct byte-identical to the original. So the full Format sequence (6, 8, 10, 38, 12, 14, 44, 28) is now proven on real hardware too. - **Ours, park-2, read-only** from the booth over SSH: both readers answered `info` + `get` (`HC009E84` @ `.7`, `HC00D3B0` @ `.8`, firmware `ver_client1_1.1`, chip `v3s`, hw `h42`). - Still unverified on a real reader: `set-network` (cmd 32). ## In the app `packages/devices/src/drivers/dingtian-qr-config.ts` is a TypeScript port of the protocol (frame, DeviceInfo/Firmware/Params codecs, two-datagram writes, discover, set-network) with a fake-reader test suite; `reader.ts` uses it for the DT-008 driver's `discover()`, preconditions and `configureInputPush()` ([[first-run-setup]], [[device-discovery]]). Extra hardware facts learned while wiring it (2026-10-08, bench HC002721): **cmd 6 alone** (no Format group) is accepted and applied; **set-network is applied but never acknowledged**, and the reader answers nothing for ~2–6 s afterwards (poll the params; the driver waits up to 12 s); the Python and TS tools build byte-identical set-network payloads. ## Usage (from a booth) ``` python3 -I scripts/dingtian_qr.py discover --broadcast 10.0.10.255 # LAN search (same L2 only) python3 -I scripts/dingtian_qr.py get 10.0.10.7 # full config, human-readable python3 -I scripts/dingtian_qr.py get 10.0.10.7 --raw --hexdump # numeric codes + 720 B dump python3 -I scripts/dingtian_qr.py set 10.0.10.7 --output-type 3 # HTTP mode (reads first, re-sends the Format group) ``` Booth hosts ship Python 3 (park-2: 3.14); copy the one file over `scp` and run it on the host (the server container has no Python). Readers are per-site on `10.0.10.x`; `set-network` needs the L2 broadcast, so it works from the booth but not across Netbird.