feat(devices): DT-008 reader discovery + auto-configuration over the vendor UDP protocol
The Dingtian DT-008's Windows-only config tool speaks a small binary UDP protocol
(reader :24680 unicast get/set, :24582 broadcast search/set-network), reversed in
wiki/raw/dingtian_qr_linux (PROTOCOL.md + dingtian_qr.py, copied to scripts/). Reading
park-2's readers with it from the booth found both in WG26 output mode — the "beeps but
captures nothing" enrolment failure: they never pushed HTTP at all.

The app now speaks the protocol itself (packages/devices dingtian-qr-config.ts, Node dgram,
host-network container) and the dingtian-qr-reader driver uses it:
- discover(): first driver to implement the wizard's Scan capability; rows show serial, IP,
  output mode, current server target, card format, firmware.
- preconditions: output type must be HTTP (fixable — save switches it); typed serial must
  equal the reported one and the reader must answer on UDP (both block the save).
- configureInputPush(): set-network the reader's server to this booth's IP + listen port,
  confirmed by polling (the reader applies it without an ack and is silent for seconds).
- usesPushAuth=false: the scan GET carries no credentials, so no push secret is stored.
- a reader saved without an IP warns instead of failing (legacy vendor-tool setup).

Verified on the bench unit: WG26→HTTP, target 8080→8081→8080, struct byte-identical after.
15 protocol tests against a fake reader + 17 adapter tests. Wiki: device-discovery,
first-run-setup, dingtian-dt008-reader, site-device-installation §2 (SSH procedure; the
"needs a Windows laptop" claim withdrawn), new source page dingtian-qr-linux-tool.
2026-10-08 15:22:33 +02:00

3.2 KiB
Raw Permalink Blame History

Dingtian QR reader – Linux configuration tool

Replacement for the Windows-only QRCode_v1_6_5.exe shipped in the Dingtian QR code reader SDK. Lets you find readers on the LAN, read their configuration and change network, output-format and behaviour settings from Linux (or any OS with Python 3).

file purpose
PROTOCOL.md the reverse engineered UDP protocol: frame format, command list, field tables, 720 byte parameter struct, verification status
dingtian_qr.py reference implementation and CLI (discover, info, get, set, set-network); importable as a module

Requirements

  • Python 3.6 or newer, standard library only.
  • The PC must be on the same layer 2 network as the readers for discover and set-network (they use UDP broadcast). info, get and set are unicast and work across routers.
  • Host firewall: allow inbound UDP replies to the tool's socket. Readers reply from arbitrary source ports, so do not filter on the reader's source port.

Usage

python3 dingtian_qr.py discover --broadcast 192.168.1.255      # list readers (serial, ip, server...)
python3 dingtian_qr.py info 192.168.1.99                        # model / firmware / serial
python3 dingtian_qr.py get 192.168.1.99                         # full configuration (add --raw for numeric codes)
python3 dingtian_qr.py set 192.168.1.99 --output-type 3 --buzzer 1 --qr-suffix "hex:0d"
python3 dingtian_qr.py set-network --serial HC002721 --ip 192.168.1.50 --netmask 255.255.255.0 \
        --gateway 192.168.1.1 --dns1 8.8.8.8 --dns2 8.8.4.4 --server 192.168.1.10 \
        --server-port 8080 --http-language 0 --broadcast 192.168.1.255
python3 dingtian_qr.py set --help                                # every field with its numeric codes

set reads the current configuration first and only changes the fields you pass; it then sends the same command sequence as the exe's Set button that owns those fields (Format group and/or External group). set-network broadcasts and the reader whose serial matches applies the new values, so it also works for a reader whose current IP is in the wrong subnet.

A factory reset (pin in the RESET hole on the back) returns the reader to 192.168.1.99.

Using it from your own code

import dingtian_qr as dq
for ip, info in dq.discover(broadcast='192.168.1.255'):
    print(info['serial'], ip)
params = dq.get_params('192.168.1.99')        # dict, keys documented in parse_params()
params['output_type'] = 3                     # HTTP
params['buzzer'] = 1
dq.set_format('192.168.1.99', params)         # commands 6,8,10,38,12,14,44,28
dq.set_external('192.168.1.99', params)       # commands 40,18,16,22

Caveats

  • The DHCP setting cannot be written: the original exe never transmits it (see PROTOCOL.md), so the reader's behaviour for it is unknown.
  • The External commands (buzzer, work mode, fill light, restart interval) were verified on a real reader. The Format commands and set-network were validated only against the exe's own packets and a simulated reader. Test on one reader before rolling out.
  • Parameter struct words 0x1f4 and the area 0x050–0x197 are not understood (the exe does not use them either).