Files
parking_solution/wiki/entities/gee-qr-er80.md
T
julian 04135b27cf qr-reader: register all server-language extensions (reader posts .jsp)
Hardware capture: the GEE/Fondvision reader (serial H05M2AFA) scans + sends +
beeps fine — the earlier 'no beep' was just nothing answering :3000. Real
request: GET /qa/mcardsea.jsp?cardid=...&cjihao=H05M2AFA&... — the 'server
language' setting (JSP here) selects the URL EXTENSION, so it posts .jsp, not
.php. Our route was .php-only and would have 404'd it.

Register the endpoint at php/jsp/asp/aspx/cgi so it works whatever the device is
configured to. cjihao (serial) is the lane key: assign the reader as
lane_devices.id = its serial.
2026-06-16 12:30:00 +02:00

5.8 KiB
Raw Blame History

type, tags, sources, updated, status
type tags sources updated status
entity
parking
hardware
readers
qr
gee-qr-er80
2026-06-16 open

GEE-QR-ER80 (QR access reader)

The project's QR-code reader (GEE NFC LIMITED). A static optical scanner for QR / DataMatrix / 1D barcode, optional ID/IC card. This is the ticket-encoding scanner the design called for — read at the pay station and exit lane — and a path for QR permit credentials. On hand: variant -Q-W (QR scanner; Wiegand/RS-232/RS-485). (See gee-qr-er80 / raw/.)

What it is (and isn't)

  • Optical, not RFID-prox. Earlier we assumed "ER80-EM" = a 125 kHz EM4100 card reader — the datasheet corrects that: it's a QR/barcode scanner. The -EM in the original label was a mis-id; the real model is GEE-QR-ER80. Optional D/C variants add ID/IC card, but the unit on hand is QR-only (-Q).
  • Multi-interface (Wiegand 26/34, RS-232, RS-485, USB, TCP/IP); the -W variant exposes Wiegand + RS-232/RS-485.

How it integrates — HTTP-GET push, server replies the verdict (confirmed via SDK)

The protocol is settled by the qrcode-sdk (not serial as first guessed). The reader is configured (Windows tool QRCode_v1_6_5.exe) with a server IP/port and a "server language" (only picks the URL path, e.g. /qa/mcardsea.php). On each scan it HTTP-GETs the host:

GET /qa/mcardsea.php?cardid=<QR>&mjihao=<devId>&cjihao=<devSN>&status=<2 chars>&time=<utc>

cardid = scanned data; status low digit = direction (1=in / 0=out). The host replies JSON {data:[{cardid,cjihao,mjihao,status,time,output}],code:0} where reply status 1=valid (beep 2×) / 0=invalid (beep 1×), output 0=Access/1=WG26/2=WG34, time syncs the clock.

This is host-in-the-loop and SYNCHRONOUS: the GET is the access query and our reply is the decision — it drives the reader's beep + output. So unlike a fire-and-forget reader, the endpoint must decide (valid/invalid, direction from status) and reply, then also emit a DeviceReadEvent on the read bus for the entry/exit/permit flows (parking-session, permit) to open the barrier. (device-input-flow is the analogous push pattern; this one also returns a verdict.)

This explains the "no beep": feedback comes from the server's JSON reply, not locally. A non-JSON / missing reply ⇒ no beep even though the scan worked. So "no beep" ≠ "didn't scan."

  • Pushes over plain HTTP to our 10.0.10.x host (on the device subnet); no serial wiring, no Wiegand-decode hardware. Suits the host-in-the-loop model; autonomy is moot anyway (dingtian-relay has no onboard ACL).
  • Linux-supported, 4–15 VDC, default IP 192.168.1.99 — fits the disk-os-hardening.

Resolved (2026-06-16)

  • Protocol = HTTP GET poll + JSON verdict (above). The earlier "serial/Wiegand, find the baud" open questions are moot — it's HTTP. Wiegand is the reader's output line on a valid read (the reply output field), not the host transport.

As-built (2026-06-16)

  • Endpoint GET/POST /qa/mcardsea.php (apps/server/src/routes/qr-reader.ts, public — the reader has no auth, sits on the device subnet). Parses cardid/mjihao/cjihao/status/time, runs the scan through the read dispatcher (permit match → permit flow; else transient exit), and replies the SDK verdict: status 1=valid(beep 2×)/0=invalid(beep 1×), output 0, time.
  • The read flows were refactored to return a ReadOutcome { accepted, direction, reason } so the endpoint's reply reflects the real accept/reject (the dispatcher decides AND opens the barrier via the flows). A fire-and-forget reader ignores the outcome.
  • Lane mapping: the endpoint keys the reader's lane_devices id off the device serial (cjihao) for now — so assign the reader with lane_devices.id = <serial>. Refine when the setup wizard models the reader's server-side identity properly.
  • Verified via inject: valid permit QR → status:1 + open; re-scan → permit exit (still valid); unknown QR → status:0; reader on a barrier-less lane → status:0.

Verified on hardware (2026-06-16)

Captured a real scan (vendor-emulator logger on :3000). The reader does scan, send, and beep — the earlier "no beep" was simply that no server was answering on :3000 with valid JSON. Real GET:

GET /qa/mcardsea.jsp?cardid=52020056&mjihao=1&cjihao=H05M2AFA&status=11&time=1781634494
from 10.0.10.7   (referer: http://www.fondvision.com — the OEM is Fondvision)
  • PATH carries the configured "server language" EXTENSION: this unit is set to JSP, so it GETs /qa/mcardsea.jsp — NOT .php. Our endpoint was registered at .php only → it would have 404'd the real reader. Fixed: the route now registers php/jsp/asp/aspx/cgi.
  • cjihao = H05M2AFA is the device serial — the value our endpoint keys the lane on. So assign the reader with lane_devices.id = "H05M2AFA" (+ an access device on the same lane).
  • mjihao = 1 (device id). cardid = the scanned barcode (52020056). status=11.
  • The reader beeped on the vendor reply with status:0 — so it acts on the reply; 0 = invalid/1-beep as documented. A matching permit/session will return status:1 → 2-beep accept.

Open / next

  • Assign the reader as lane_devices.id = "H05M2AFA", category reader, on the same lane as an access device, so the endpoint resolves the lane. (The setup wizard doesn't yet capture a reader's serial as its id — manual row or a wizard tweak; see first-run-setup.)
  • Re-test against the real app endpoint (now .jsp-aware): scan → expect the GET to hit /qa/mcardsea.jsp and a status:1 2-beep when the credential matches a permit/open session.