julian 2a86e578a8 Dingtian harden(): rotate the admin/admin web login (cosmetic)
harden() now rotates the device's default admin/admin web-UI login via
GET /userset.cgi?<old>&<old>&<new>&<new>& (best-effort: a failure logs
and doesn't fail the assign). The new password is stored back in config
(webUser/webPassword) so a re-run can rotate again, and is stripped from
the assign response like the push secret.

Documented the load-bearing caveat: this device's CGI API is fully
UNAUTHENTICATED — config read/write, relay fire, and userset.cgi itself
all return 200 with no credentials (verified on hardware). admin/admin
gates only the browser UI, and there's no inbound-auth setting (only
session_en, which bricks the read API). So the rotation is defence-in-
depth for the UI, NOT a boundary; the signed event log remains the real
anti-fraud guarantee. Verified rotation end-to-end on 10.0.10.5
(success &0&, wrong-old-pw &2&); device left at admin/admin.
2026-06-14 19:00:42 +02:00

7.6 KiB
Raw Blame History

type, tags, sources, updated
type tags sources updated
entity
parking
hardware
access-control
relay
2026-06-14

Dingtian Relay Controller

A network relay + input board (the unit on hand is the 4-channel variant: 4 relays + 4 inputs). Chosen to drive the entry/exit lane because — unlike the uhppote-controller — its inputs are independent of its relays, which solves the access-controller-button-flow blocker (a button on an input does not auto-open a relay; the host decides).

SDK: dingtian/4ch/sdk_v2_0_0/ (programming manual, examples). MIT-compatible use; no vendor runtime needed.

By default the device links each input to auto-fire its matching relay (input_link_relay: 1, on_action_on: [[0],[1],…] in the config) — i.e. the same auto-open problem as the UHPPOTE. The difference: it is configurable. Set input_link_relay: 0 (or clear the action mappings) so an input only reports and the host commands the relay. This config step is mandatory for the ticket-first entry flow. See autonomous-direction.

Protocol (Dingtian string — what we use)

Transport options: UDP/TCP string, UDP binary, HTTP CGI, Modbus, MQTT. We use HTTP + UDP — see dingtian-vs-mqtt.

  • Relay control — UDP binary, port 60000 (authenticated): the driver's pulseOpen sends a binary "write relay with jogging" frame carrying the relay_pw (the only relay option with a password). Frame (verified on hardware): FF AA <session> 03 <pwLo> <pwHi> <relayByte> <jogLo> <jogHi> — relayByte bit0=on, bits1-7= channel-1; jog is 100 ms units, LSB-first; password 16-bit LSB-first (0 = none). The relay jogs ON then auto-releases, so we never time a close (barrier-not-a-door). (The simpler string protocol — 1+ch on, 2+ch off, 11* jog — works too but has no auth; we use it only for the read-only status query.)
  • Status / inputs — send 00 → 「relays」:「inputs」:「count」, e.g. 0000:1111:4 (4ch: relays off, inputs high). 0 = OFF/Low, 1 = ON/High. Poll-based.
  • Input push — input_link_url: device HTTP POSTs to a host URL on input change — the push path for button events without a broker.
  • Discovery: UDP multicast 224.0.2.11:60000, send \x05\xAA (devices reply). Defaults: IP 192.168.1.100, UDP 60000 (binary) / 60001 (string).
  • Binary protocol (port 60000) adds optional password + multicast; bitmask relay/input maps.

Driver & config API

The dingtian driver (device-registry) implements three capabilities: AccessControlDevice (relay pulse/latch over UDP), InputDevice (read inputs + poll-based press/release events ~50 ms), and PreconditionDevice (below). Config fields include a separate httpPort — the device's web/config API is on a configurable HTTP port (default 80), distinct from the UDP control port 60001.

The driver reads the device's JSON config (GET /api/v2/config.cgi) and checks input_link_relay; if enabled it reports a fixable issue, and fixPreconditions() writes the correction (POST /api/v2/config_set.cgi) — setting the flag to 0 and clearing on_action_on, preserving everything else (network, etc.). This is the generic device-registry capability: the app doesn't own full device config (that's the vendor web UI), only the few settings our flow depends on.

Write gotcha (cost real debugging): the GET config payload omits a "command" field, but the set endpoint requires "command":"setconfig" injected right after "status". Without it the POST returns/looks like success but silently does nothing (and the device may reset). With it, POST returns {"status":0} and the change sticks. JSON node order must be preserved.

Input push (no polling) — the chosen architecture

The device pushes button events to the backend; the backend decides. No polling. The driver's configureInputPush() writes the device's input_link_url config to point each input at the backend: input N HTTP-GETs …/api/devices/dingtian/<deviceId>/input/<N>/on (and /off) on press/release. The backend (fastify route routes/devices.ts) translates each push into an internal device event (device-input-flow); the entry flow then prints a ticket and commands the relay via UDP. See device-input-flow for the full path + trust model.

The input-poll path in the driver (onInput) remains as a dev/fallback aid, but push is the real path — lower latency, and it can be authenticated (the device supports Basic/Digest + HTTPS on the push), unlike the open UDP control direction.

Hardening (harden()) — and why HTTP auth is not a boundary here

On assign the driver runs harden() (the device-registry capability):

  1. relay_pw — set a random relay password so binary relay commands (UDP 60000) need it.
  2. Disable unused channels — set p:255 on rs485/can/tcp×2/mqtt; keep only UDP1 binary (relay control) + UDP2 string (status read).
  3. Rotate the admin/admin web login — GET /userset.cgi?<old_u>&<old_p>&<new_u>&<new_p>& (response &0&…& = success, verified on hardware). The new password is stored back in config (webUser/webPassword) so a re-run can rotate again (the device checks the old creds). This step is best-effort — a failure logs and does not fail the assign.

⚠️ The device CGI API is UNAUTHENTICATED. Verified on hardware: GET /api/v2/config.cgi, /, and even /userset.cgi all return 200 with no credentials. The admin/admin login gates only the interactive browser UI — the CGI control plane (read/write full config, fire relays, change the password) bypasses it entirely. The http config block has no setting to require Basic/Digest on inbound requests; the only inbound gate is session_en, which bricks the config-read API on this firmware (the factory-reset incident — do not enable it). So rotating the login is cosmetic (stops a casual browser reaching settings); it is not a boundary. On this flat, no-VLAN network the device control plane is effectively open — the signed event log is the real anti-fraud guarantee. See device-input-flow.

⚠️ session_en must stay OFF. Enabling the HTTP CGI session check makes the config-read API drop connections (ECONNRESET), locking out the API the driver depends on — recoverable only by factory reset. harden() deliberately never touches it.

Status — VERIFIED on hardware (DT-R004, sw V3.1.5461A, 10.0.10.172)

  • ✅ status read (0000:1111:4), relay pulse, input press/release events (active-LOW, idle HIGH).
  • ✅ input_link_relay disabled via the driver → pressing an input reports the event and fires NO relay (0000 after presses). The access-controller-button-flow blocker is solved.
  • ✅ Input HTTP-push end to end — configured the device via configureInputPush(), then real button presses (all 4 inputs) pushed to the backend (/input/N/on + /off per press, source = the device IP). No polling. Host-in-the-loop entry (button → backend → ticket → backend opens relay) is real.
  • ✅ Web-login rotation — userset.cgi rotates admin/admin (response &0&/&; wrong old password → &2&/&). Confirmed the device validates the old creds. Also confirmed the CGI API needs NO auth (config dump + userset.cgi return 200 unauthenticated) → rotation is cosmetic.
  • ⬜ Next: wire the actual entry flow (input event → signed event + print ticket → pulseOpen).