The dahua driver decremented the wizard's channel on the belief the CGI is 0-based. On real hardware (IPC-HFW2549T-AS-IL, fw V2.880, 2026-09-17) snapshot.cgi?channel=0 answers HTTP 400 and channel=1 returns the 2880x1620 JPEG — so every Dahua assignment sat at degraded "HTTP 400". The channel is now sent as entered (clamped >= 1) and the URL is pinned in camera.test.ts. DahuaCamera.syncClock reads global.cgi getCurrentTime and, past the drift limit, writes setCurrentTime with the host's naive local wall time (no offset): the OSD burned into snapshots must match the booth clock; the camera's tz/DST config is left alone. Verified live: a 2h-off set, set back, 1s drift -> no write. The device monitor picks it up via isClockSyncable unchanged. Wiki: new entities/dahua-ipc-hfw2549t.md (endpoint table, verbatim eventManager attach parts — VideoMotion Start/Stop, VideoMotionInfo, TimeChange — RealUTC is the camera's belief of UTC, 5-strike login lockout, unit not factory-fresh); lpr-camera Dahua bullet corrected; runbook §3 Dahua paragraph; index + log. The server-side attach-stream subscriber is not built.
9.1 KiB
type, tags, sources, updated
| type | tags | sources | updated | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| entity |
|
2026-09-17 |
Dahua IPC-HFW2549T-AS-IL — the lab bench unit (inspected 2026-09-17)
A 5 MP Dahua WizSense bullet (IPC-HFW2549T-AS-IL-0360B, 3.6 mm, "IL" = smart dual illuminators),
firmware V2.880.0000000.22.R, build 2026-05-14, serial 9J0E4EFPAGECB23, MAC
fc:5f:49:48:42:ac, processor SSC378Q. Sits on the bench at 10.0.10.11, login admin / the lab
password. It is not an ANPR camera — plates come from the host-side opencv-anpr-service
off its snapshot, exactly as with the Hikvision units. Everything below was read off the unit
over its CGI with curl --digest; nothing was written to it.
It is not factory-fresh. Hostname DAHUA_PORTA_KRYESORE ("main gate"), an Alarm Server already
pointed at 10.7.8.9:8888, DNS 8.8.8.8, SMD tuned to vehicles only — this unit was configured
for a gate somewhere before it reached the bench. Treat its settings as inherited, not defaults.
What the CGI surface gives us
| Need | Endpoint (all HTTP Digest, port 80; 443 is off) | Result on this unit |
|---|---|---|
| identity | magicBox.cgi?action=getSystemInfo / getSoftwareVersion / getSerialNo / getVendor |
model, firmware, serial, vendor=Dahua |
| snapshot | snapshot.cgi?channel=1 |
200, image/jpeg, 2880×1620, ~270 KB, ~0.5 s |
snapshot channel 0 / 2 |
same | 400 — the channel index is 1-based; subtype=1 is ignored (still 2880×1620) |
| clock read | global.cgi?action=getCurrentTime |
result=2026-09-17 09:03:50 |
| clock write | global.cgi?action=setCurrentTime&time=YYYY-MM-DD%20HH:MM:SS |
200 OK; read-back matches within 1 s (verified, now the Dahua clock-sync) |
| events | eventManager.cgi?action=attach&codes=[All]&heartbeat=5 |
200, multipart/x-mixed-replace, a Heartbeat part every N s, event parts in between |
| event caps | eventManager.cgi?action=getCaps |
snapshot/record/mail/alarm-out linkage; no HTTP push cap |
| streams | RTSP 554 cam/realmonitor?channel=1&subtype=0 / 1 |
H.265 Main 2880×1620 @ 20 fps; sub 704×576 @ 20 fps (probed with ffprobe) |
| ports | 80 (HTTP), 554 (RTSP), 37777 (Dahua SDK/DHIP) open; 443, 37778, 5000, 8000 closed |
Snapshot: the driver decremented the channel — this unit said no (fixed 2026-09-17)
dahuaDriver (packages/devices/src/drivers/camera.ts) builds
/cgi-bin/snapshot.cgi?channel=${ch-1} on the note "Dahua channels are 0-based". On this firmware
channel=0 → HTTP 400, channel=1 → the JPEG. Dahua's HTTP API numbers snapshot.cgi and
realmonitor channels from 1 (only the configManager tables are 0-indexed — the usual source
of the confusion). So an admin who enters "channel 1" in the wizard gets a permanent degraded
"HTTP 400" from healthCheck() and no snapshot ever. The Dahua driver was never run against
hardware before today (lpr-camera §Verified only covers Hikvision). Fixed the same day: the
driver now sends the channel as entered (clamped to ≥1) and camera.test.ts pins the URL. The
fixed driver was then run against this unit: healthCheck → ready (≈256 KB), captureSnapshot →
image/jpeg, 273 KB, JPEG magic.
The snapshot always comes off the main stream at full resolution — there is no per-stream
snapshot as on Hikvision, and subtype on snapshot.cgi is ignored. Fine for us: the app
re-encodes to 1280 px on capture (snapshot-storage-optimization) and the recognizer keeps the
full frame.
Events: Dahua PULLS-with-a-held-socket, it does not HTTP-POST
Dahua has an "Alarm Server" too (configManager.cgi?action=getConfig&name=AlarmServer), but its
protocol is DAHUA (proprietary, port 8888) — not the Hikvision-style HTTP POST that
routes/hikvision-alarm.ts consumes. The HTTP way to get events is the subscription stream:
the host opens eventManager.cgi?action=attach&codes=[SmartMotionVehicle,CrossLineDetection,…]&heartbeat=5
and keeps it open; the camera writes one multipart part per event (Code=…;action=Start|Stop;index=…)
and a Heartbeat part every 5 s. Verified on the bench: the stream stays up, heartbeats arrive,
Digest auth applies to the attach. This inverts the Hikvision model:
- the camera never needs to know the booth's address — no
pushesToBackend, no "assign first, then go back to the camera" step, no source-IP guard, and the WSL mirrored-mode source-IP problem does not exist; - the server owns the connection: reconnect with backoff, treat a missing heartbeat as camera-offline, one long-lived socket per Dahua camera;
- vehicle events come from SMD (
SmartMotionDetect:Enable=true,ObjectTypes.Vehicle=true,Human=falseon this unit — inherited, and exactly the "Detection Target = Vehicle" the Hikvision runbook step asks for) → codeSmartMotionVehicle; tripwire/intrusion (CrossLineDetection,CrossRegionDetection) withObjectTypes=Vehicleare the IVS equivalents, none configured on this unit (only disabled FaceDetection and HeatMap rules exist).
Verbatim event parts captured on a 25-minute codes=[All] listen (bench motion + the clock
write below). Each part is Content-Type: text/plain with a Code=…;action=…;index=…;data={JSON}
body:
Code=VideoMotion;action=Start;index=0;data={
"EventID" : 31927,
"Id" : [ 0 ],
"RealUTC" : 1789634136,
"RegionName" : [ "Region1" ],
"SmartMotionEnable" : true,
"WithSnap" : true
}
Code=VideoMotion;action=Stop;index=0;data={ …same EventID… }
Code=VideoMotionInfo;action=State;index=0;data={ "RealUTC" : 1789634137, "WithSnap" : false }
Code=TimeChange;action=Pulse;index=0;data={
"BeforeModifyTime" : "17-09-2026 09:35:51",
"ModifiedTime" : "17-09-2026 10:35:49",
"RealUTC" : 1789637749,
"WithSnap" : false
}
action=Start/Stopwith a sharedEventIDis the busy/free edge (the Hikvisionactive/inactiveequivalent);VideoMotionInfo Stateis a per-second chatter part to ignore.- The motion arrived as plain
VideoMotionwithSmartMotionEnable: true, not asSmartMotionVehicle— whether the SMD filter suppressesVideoMotionfor non-vehicles, or only adds theSmartMotion*codes on top, is unconfirmed (nobody drove a car past the bench). Subscribe to both and log which fires before gating anything on it. RealUTCis the camera's belief of UTC, i.e. its wall time minus its configured offset. After the clock write it read 09:35:49 for a real 08:35:49 UTC (UTC+1, DST off). Never use it as an absolute time — stamp events on receipt from the booth clock, as the Hikvision route does.TimeChangeis emitted for our own clock sync; harmless, but filter it from any "activity" view.
Clock: one hour behind, NTP off — clock-sync built the same day
getCurrentTime returned 09:03 while the bench wall clock read 10:03 CEST: NTP.Enable=false
(address time.windows.com, unreachable on an isolated VLAN anyway), NTP.TimeZone=1 (Belgrade)
and Locales.DSTEnable=false, so the unit runs at UTC+1 year-round. The Hikvision units get
their clock from the booth at every offline→ready edge (clock-integrity); until today the
Dahua driver did not claim isClockSyncable. Now DahuaCamera.syncClock (camera.ts) reads
global.cgi?action=getCurrentTime (result=YYYY-MM-DD HH:MM:SS) and, past the drift limit, writes
setCurrentTime&time=<host wall time> — the host's naive local wall time, no offset, because
what has to match the booth is the OSD burned into every snapshot, not the camera's notion of UTC
(its tz/DST config is left alone, as on Hikvision). Verified on the bench with the real driver:
a 2 h-off host time set (drift 7200 → synced), set back, then read as 1 s drift → no write. The
device monitor picks it up unchanged (it gates on isClockSyncable, not on the driver id). A wrong
DST setting on the camera therefore no longer matters for the evidence trail — only RealUTC in
event bodies stays skewed (above).
Login lockout — the device monitor must never poll with a wrong password
General.LockLoginEnable=true, LockLoginTimes=5, LoginFailLockTime=300: five bad Digest
logins lock admin out for 5 minutes. A wizard assignment with a mistyped password, polled every
few seconds by the device monitor, locks the camera and then every login (including the
browser) fails until the poll stops. Verify the password with one curl before assigning; on a
mysterious "401 then nothing works" wait five minutes.
Bench notes
10.0.10.11is the runbook's address for the lab k200l-printer (site-device-installation §address plan) — the camera has taken it on the bench; keep the two off the wire together or move one.- The other HTTP APIs newer Dahua firmware carries (
RPC2JSON,/onvif/device_service) were not exercised — the CGI above covers everything the app needs. devVideoInput.cgi?action=getCapsandmagicBox.cgi?action=getProductDefinitionanswer "Bad Request" / "Not Implemented" on this firmware.
Related: lpr-camera · opencv-anpr-service · lane-presence-and-anpr-entry · clock-integrity · site-device-installation · device-registry