fix(devices): Dahua snapshot channel is 1-based; add Dahua clock sync; wiki page for the bench IPC-HFW2549T
The dahua driver decremented the wizard's channel on the belief the CGI is
0-based. On real hardware (IPC-HFW2549T-AS-IL, fw V2.880, 2026-09-17)
snapshot.cgi?channel=0 answers HTTP 400 and channel=1 returns the 2880x1620
JPEG — so every Dahua assignment sat at degraded "HTTP 400". The channel is
now sent as entered (clamped >= 1) and the URL is pinned in camera.test.ts.

DahuaCamera.syncClock reads global.cgi getCurrentTime and, past the drift
limit, writes setCurrentTime with the host's naive local wall time (no offset):
the OSD burned into snapshots must match the booth clock; the camera's tz/DST
config is left alone. Verified live: a 2h-off set, set back, 1s drift -> no
write. The device monitor picks it up via isClockSyncable unchanged.

Wiki: new entities/dahua-ipc-hfw2549t.md (endpoint table, verbatim
eventManager attach parts — VideoMotion Start/Stop, VideoMotionInfo,
TimeChange — RealUTC is the camera's belief of UTC, 5-strike login lockout,
unit not factory-fresh); lpr-camera Dahua bullet corrected; runbook §3 Dahua
paragraph; index + log. The server-side attach-stream subscriber is not built.
2026-10-08 08:03:50 +02:00

9.1 KiB
Raw Blame History

type, tags, sources, updated
type tags sources updated
entity
parking
hardware
camera
dahua
snapshot
events
bench
2026-09-17

Dahua IPC-HFW2549T-AS-IL — the lab bench unit (inspected 2026-09-17)

A 5 MP Dahua WizSense bullet (IPC-HFW2549T-AS-IL-0360B, 3.6 mm, "IL" = smart dual illuminators), firmware V2.880.0000000.22.R, build 2026-05-14, serial 9J0E4EFPAGECB23, MAC fc:5f:49:48:42:ac, processor SSC378Q. Sits on the bench at 10.0.10.11, login admin / the lab password. It is not an ANPR camera — plates come from the host-side opencv-anpr-service off its snapshot, exactly as with the Hikvision units. Everything below was read off the unit over its CGI with curl --digest; nothing was written to it.

It is not factory-fresh. Hostname DAHUA_PORTA_KRYESORE ("main gate"), an Alarm Server already pointed at 10.7.8.9:8888, DNS 8.8.8.8, SMD tuned to vehicles only — this unit was configured for a gate somewhere before it reached the bench. Treat its settings as inherited, not defaults.

What the CGI surface gives us

Need Endpoint (all HTTP Digest, port 80; 443 is off) Result on this unit
identity magicBox.cgi?action=getSystemInfo / getSoftwareVersion / getSerialNo / getVendor model, firmware, serial, vendor=Dahua
snapshot snapshot.cgi?channel=1 200, image/jpeg, 2880×1620, ~270 KB, ~0.5 s
snapshot channel 0 / 2 same 400 — the channel index is 1-based; subtype=1 is ignored (still 2880×1620)
clock read global.cgi?action=getCurrentTime result=2026-09-17 09:03:50
clock write global.cgi?action=setCurrentTime&time=YYYY-MM-DD%20HH:MM:SS 200 OK; read-back matches within 1 s (verified, now the Dahua clock-sync)
events eventManager.cgi?action=attach&codes=[All]&heartbeat=5 200, multipart/x-mixed-replace, a Heartbeat part every N s, event parts in between
event caps eventManager.cgi?action=getCaps snapshot/record/mail/alarm-out linkage; no HTTP push cap
streams RTSP 554 cam/realmonitor?channel=1&subtype=0 / 1 H.265 Main 2880×1620 @ 20 fps; sub 704×576 @ 20 fps (probed with ffprobe)
ports 80 (HTTP), 554 (RTSP), 37777 (Dahua SDK/DHIP) open; 443, 37778, 5000, 8000 closed

Snapshot: the driver decremented the channel — this unit said no (fixed 2026-09-17)

dahuaDriver (packages/devices/src/drivers/camera.ts) builds /cgi-bin/snapshot.cgi?channel=${ch-1} on the note "Dahua channels are 0-based". On this firmware channel=0 → HTTP 400, channel=1 → the JPEG. Dahua's HTTP API numbers snapshot.cgi and realmonitor channels from 1 (only the configManager tables are 0-indexed — the usual source of the confusion). So an admin who enters "channel 1" in the wizard gets a permanent degraded "HTTP 400" from healthCheck() and no snapshot ever. The Dahua driver was never run against hardware before today (lpr-camera §Verified only covers Hikvision). Fixed the same day: the driver now sends the channel as entered (clamped to ≥1) and camera.test.ts pins the URL. The fixed driver was then run against this unit: healthCheck → ready (≈256 KB), captureSnapshot → image/jpeg, 273 KB, JPEG magic.

The snapshot always comes off the main stream at full resolution — there is no per-stream snapshot as on Hikvision, and subtype on snapshot.cgi is ignored. Fine for us: the app re-encodes to 1280 px on capture (snapshot-storage-optimization) and the recognizer keeps the full frame.

Events: Dahua PULLS-with-a-held-socket, it does not HTTP-POST

Dahua has an "Alarm Server" too (configManager.cgi?action=getConfig&name=AlarmServer), but its protocol is DAHUA (proprietary, port 8888) — not the Hikvision-style HTTP POST that routes/hikvision-alarm.ts consumes. The HTTP way to get events is the subscription stream: the host opens eventManager.cgi?action=attach&codes=[SmartMotionVehicle,CrossLineDetection,…]&heartbeat=5 and keeps it open; the camera writes one multipart part per event (Code=…;action=Start|Stop;index=…) and a Heartbeat part every 5 s. Verified on the bench: the stream stays up, heartbeats arrive, Digest auth applies to the attach. This inverts the Hikvision model:

  • the camera never needs to know the booth's address — no pushesToBackend, no "assign first, then go back to the camera" step, no source-IP guard, and the WSL mirrored-mode source-IP problem does not exist;
  • the server owns the connection: reconnect with backoff, treat a missing heartbeat as camera-offline, one long-lived socket per Dahua camera;
  • vehicle events come from SMD (SmartMotionDetect: Enable=true, ObjectTypes.Vehicle=true, Human=false on this unit — inherited, and exactly the "Detection Target = Vehicle" the Hikvision runbook step asks for) → code SmartMotionVehicle; tripwire/intrusion (CrossLineDetection, CrossRegionDetection) with ObjectTypes=Vehicle are the IVS equivalents, none configured on this unit (only disabled FaceDetection and HeatMap rules exist).

Verbatim event parts captured on a 25-minute codes=[All] listen (bench motion + the clock write below). Each part is Content-Type: text/plain with a Code=…;action=…;index=…;data={JSON} body:

Code=VideoMotion;action=Start;index=0;data={
   "EventID" : 31927,
   "Id" : [ 0 ],
   "RealUTC" : 1789634136,
   "RegionName" : [ "Region1" ],
   "SmartMotionEnable" : true,
   "WithSnap" : true
}
Code=VideoMotion;action=Stop;index=0;data={ …same EventID… }
Code=VideoMotionInfo;action=State;index=0;data={ "RealUTC" : 1789634137, "WithSnap" : false }
Code=TimeChange;action=Pulse;index=0;data={
   "BeforeModifyTime" : "17-09-2026 09:35:51",
   "ModifiedTime" : "17-09-2026 10:35:49",
   "RealUTC" : 1789637749,
   "WithSnap" : false
}
  • action=Start / Stop with a shared EventID is the busy/free edge (the Hikvision active/inactive equivalent); VideoMotionInfo State is a per-second chatter part to ignore.
  • The motion arrived as plain VideoMotion with SmartMotionEnable: true, not as SmartMotionVehicle — whether the SMD filter suppresses VideoMotion for non-vehicles, or only adds the SmartMotion* codes on top, is unconfirmed (nobody drove a car past the bench). Subscribe to both and log which fires before gating anything on it.
  • RealUTC is the camera's belief of UTC, i.e. its wall time minus its configured offset. After the clock write it read 09:35:49 for a real 08:35:49 UTC (UTC+1, DST off). Never use it as an absolute time — stamp events on receipt from the booth clock, as the Hikvision route does.
  • TimeChange is emitted for our own clock sync; harmless, but filter it from any "activity" view.

Clock: one hour behind, NTP off — clock-sync built the same day

getCurrentTime returned 09:03 while the bench wall clock read 10:03 CEST: NTP.Enable=false (address time.windows.com, unreachable on an isolated VLAN anyway), NTP.TimeZone=1 (Belgrade) and Locales.DSTEnable=false, so the unit runs at UTC+1 year-round. The Hikvision units get their clock from the booth at every offline→ready edge (clock-integrity); until today the Dahua driver did not claim isClockSyncable. Now DahuaCamera.syncClock (camera.ts) reads global.cgi?action=getCurrentTime (result=YYYY-MM-DD HH:MM:SS) and, past the drift limit, writes setCurrentTime&time=<host wall time> — the host's naive local wall time, no offset, because what has to match the booth is the OSD burned into every snapshot, not the camera's notion of UTC (its tz/DST config is left alone, as on Hikvision). Verified on the bench with the real driver: a 2 h-off host time set (drift 7200 → synced), set back, then read as 1 s drift → no write. The device monitor picks it up unchanged (it gates on isClockSyncable, not on the driver id). A wrong DST setting on the camera therefore no longer matters for the evidence trail — only RealUTC in event bodies stays skewed (above).

Login lockout — the device monitor must never poll with a wrong password

General.LockLoginEnable=true, LockLoginTimes=5, LoginFailLockTime=300: five bad Digest logins lock admin out for 5 minutes. A wizard assignment with a mistyped password, polled every few seconds by the device monitor, locks the camera and then every login (including the browser) fails until the poll stops. Verify the password with one curl before assigning; on a mysterious "401 then nothing works" wait five minutes.

Bench notes

  • 10.0.10.11 is the runbook's address for the lab k200l-printer (site-device-installation §address plan) — the camera has taken it on the bench; keep the two off the wire together or move one.
  • The other HTTP APIs newer Dahua firmware carries (RPC2 JSON, /onvif/device_service) were not exercised — the CGI above covers everything the app needs.
  • devVideoInput.cgi?action=getCaps and magicBox.cgi?action=getProductDefinition answer "Bad Request" / "Not Implemented" on this firmware.

Related: lpr-camera · opencv-anpr-service · lane-presence-and-anpr-entry · clock-integrity · site-device-installation · device-registry