Files
ESP32-S3-LCD-1.3/wiki/log.md
T

10 KiB
Raw Blame History

Log

Append-only. grep "^## \[" log.md | tail -5 for recent activity.

[2026-09-21] setup | Wiki instantiated

Created schema (CLAUDE.md, modelled on the sibling 5B wiki with a sibling-reference convention and a no-files-outside-this-repo directive), index.md, log.md, and four seed pages from repo knowledge plus the day's investigation: esp32-s3-lcd-1-3, controller-link, link-redundancy, patrol-gauge-outputs, open-questions. Two sources: pinout-photo-details-7 (photo copied from .docs/ into raw/) and waveshare-wiki-esp32-s3-lcd-1-3 (condensed web fetch, flagged for a verbatim re-clip). Deleted Obsidian's default Welcome.md.

Findings recorded during setup:

  • Header pinout verified from the photo: IO1–5 and IO7–14, 13 free-function GPIOs; the wiring guide's IO35–42 table is wrong.
  • Controller A cannot drive the Patrol gauges (no free native GPIO; DO terminals are I2C-expander + optocoupler). B can, via LEDC on IO7/IO8 — proposal only.
  • A transmits on GPIO 44 (code), not 43 (two stale docs). GPIO 44 leaves the 5B only as an RS485 A/B pair — how that reaches B's IO1 is unknown and is now open question #1.
  • The two repos' gear_position_t enums have drifted (Sport/Manual vs M1–M6 at values 4+). Open question #2.
  • The packet has no RPM field; A has RPM verified from CAN 0x0AA. engine_oil_temp has no real source on this engine.
  • Redundancy design space captured (RS485 / BLE GATT / ESP-NOW; failover on B; A transmits on both paths always). Nothing decided.

[2026-09-21] update | .docs folder retired; root CLAUDE.md created

The repo's .docs/ folder (14 files) was deleted (user decision). Its still-true content — verified display pins, brightness API, SquareLine export rules, CH343 serial notes, link facts — was distilled into a new root CLAUDE.md; the stale parts (backlight on GPIO 2/15, SPI on 10/11, native USB-CDC, the IO35–IO42 header table, the phase roadmap, the pin-hunting guides) were dropped. UART_PROTOCOL.md now exists only in the 5B repo at docs/UART_PROTOCOL.md. README.md repointed to CLAUDE.md and wiki/. Wiki citations that named .docs/ files were reworded to "former … (deleted 2026-09-21)"; open-questions wishlist gained the Waveshare schematic and demo-zip URLs recovered from the old troubleshooting doc. No page content changed otherwise.

[2026-09-21] update | Tach = 4 pulses/rev (user); coolant gauge characterisation procedure

User states the Patrol cluster's tachometer expects 4 pulses per revolution (recorded as user-stated, not bench-verified). Clarified that the coolant gauge is a current/resistance meter with no pulse count; added a bench procedure (pot sweep for the resistance → needle curve, sender-wire voltage to tell bimetal/regulated from series coil, series current for MOSFET sizing, PWM 500 Hz–2 kHz clear of any instrument-voltage-regulator chopper, empirical °C → duty lookup, tach pull-up check and two-frequency verification) to patrol-gauge-outputs. open-questions #3 and #7 reworded accordingly.

[2026-09-21] ingest | temp_stage.cfd — the user's old CANNY 5.3 pico temp-gauge program decoded

raw/temp_stage.cfd (CannyLab, proprietary binary) walked as 165 [type][len][payload] records; block names, constants, wiring and an Albanian comment recovered → temp-stage-cfd. Result: CAN 500k, filter 0x1D0, low byte of D1:D0 minus 48 = °C (matches the 5B's verified decode), duty = ((T − 40)·15 + 1100)/10 = 1.5·T + 50 on a 0–255 PWM period, output enabled above a minimum temperature, push-pull pin with PWM pull-up. Not in the file: PWM base clock and the external drive circuit. patrol-gauge-outputs gained a prior-art section and a starting LEDC law; open-questions #7 partly answered, #13 added; index updated.

[2026-09-21] update | Calibration parameters to live on A; ESP32 as frequency meter for the CANNY

User has the CANNY unit but no scope, and wants tunable variables on the 5B for both gauges. Recorded on patrol-gauge-outputs: the proposed gauge_calibration_t (tach ppr/trim/clamps; temp PWM Hz, slope/offset, min-temp gate, clamp; enables; calibration override) pushed A → B in a v2 config packet, and the plan to measure the CANNY's PWM frequency/duty with a 1.3 header GPIO + pulse counter instead of a scope. Suggested order: counter sketch → v2 header → A NVS/config TX/serial tuning → B RX + LEDC → A settings UI.

[2026-09-21] update | Frequency-counter sketch demoted to fallback

User decision: do not measure the CANNY's PWM first; implement the v2 protocol and B's LEDC outputs directly, and only feed the CANNY's PWM pin into a free 1.3 header GPIO for troubleshooting if the gauges misbehave. Coolant PWM frequency will default to 1 kHz (tunable from A) in the absence of a measurement. Proposed implementation defaults awaiting the user's go: split gear bytes (lever + target/engaged nibbles), A-side alert bitmap (coolant ≥ 100 °C, gearbox ≥ 130 °C, gearbox cooling demand, battery < 11.0 V, gear mismatch), 16-bit rpm, config packet from A's NVS via serial console first, B outputs tach IO7 / temp IO8 on separate LEDC timers, off when link down or value invalid.

Added a bench-wiring section to controller-link: 3.3 V RS485→TTL module on B (MAX3485/SP3485), 5B 485_A/485_B/GND → module → RO to IO1, VCC from 3V3, DE/RE low; termination note (shared CAN/RS485 switch, OFF before the car); the bare-A-line shortcut flagged as unreliable; a v1 baseline check (CAN toggle ON → default packets at 5 Hz → B reports established, zero errors) to run before the v2 protocol work. Running this check answers open question #1.

[2026-09-21] update | No RS485 module on hand — zero-parts bench options

User has no RS485→TTL module. Re-assessed the bare 485_A → IO1 shortcut against the 5B schematic: SP3485 at 3.3 V, auto-direction drives only zeros, 4.7 kΩ bias holds A high → effectively a 3.3 V UART signal when unterminated; recorded on controller-link as the bench-only first try (unverified). Wireless leg (ESP-NOW first, BLE later) to be built alongside the v2 protocol regardless; B-as-I2C-slave noted and not pursued.

Both boards flashed from current sources (5B → COM11, 1.3 → COM10). Bench check with 485_A → IO1 + GND, no transceiver on B, 120 Ω OFF: B reports connection established, 38 packets / 10 s, 0 checksum / 0 framing errors, valid flags 0x3F, debug flag mirrored; A logs 23-byte packets on GPIO 44 every 200 ms (UART auto-started from NVS). Open question #1 answered for the bench and re-scoped to "will it survive the car". controller-link updated. Note: opening the 5B's USB-CDC port from the PC resets the board.

[2026-09-21] update | Protocol v2 + ESP-NOW + gauge outputs implemented and bench-verified

Implemented in both repos (not yet committed): shared header v2 (typed DATA/CONFIG frames, gear_lever + target/engaged nibbles, engine_rpm, alerts bitmap, link_config_t); A: Tunables (NVS + cfg serial console), EspNowLink (broadcast leg, radio held in STA), UART manager sends every frame on both paths, CAN driver publishes gear pieces + evaluates alerts; B: UARTReceiver::processFrame() shared by the UART framing task and the new EspNowReceiver (channel hopping), dedupe on packet_id, CONFIG cache in NVS, GaugeOutputs (tach IO7 14-bit LEDC, coolant IO8 8-bit PWM), gear label pulses while target != engaged and turns red on mismatch, icons driven by A's alert bits. Bench: 42/42/42 frames applied/uart/espnow with 42 duplicates and 0 errors; ESP-NOW locked on ch 1; CONFIG on both paths; cfg override rpm 2000 -> 133.3 Hz on IO7; coolant 89 C -> duty 183. Two bench-found fixes: tach needs 14-bit LEDC resolution (8-bit cannot reach 100 Hz) and the shared temperature formatter must not emit a degree sign (B's font lacks the glyph). Pages updated: controller-link, link-redundancy, patrol-gauge-outputs, open-questions (#2, #4, BLE-vs-ESP-NOW and tunables-location moved to Answered; #5/#5b reworded); index updated.

[2026-09-21] update | Gauge Tuning touchscreen page on A; calibration procedure filed

A gained a hand-coded LVGL Gauge Tuning screen (Home → right → Driveline → right): −/+ rows for every link_config_t field, enable switches, and an override panel with RPM/duty sliders; changes go through Tunables (saved + pushed), overrides never persisted (A's NVS save strips them). Built and flashed. Step-by-step needle calibration procedure added to patrol-gauge-outputs.

[2026-09-27] update | SquareLine retired on Controller B; LVGL lock; oil quadrant dropped; 16 MB flash declared

Mirror of the A-side clean-up. include/ui/ (SquareLine export) deleted; the screen is now src/modules/gauge_screen.cpp - same layout minus the engine-oil cell (user decision, closes open question #8: the M57N has no oil temperature sensor), battery centred at the bottom. Kept the two fonts and six icons the screen uses as plain LVGL arrays in src/assets/. New DisplayInit::lock()/unlock() recursive mutex: lvglTask renders under it and loop() updates under it - before, the higher-priority render task could preempt loop() mid-lv_label_set_text(), the bug class that froze A. Labels, colours and icons are written only on change. DebugMonitor now records A's debug flag in the receiver and applies it from loop() under the lock (it used to touch LVGL from the ESP-NOW callback). lv_conf.h: 128 KB pool in PSRAM, logging off, LV_TICK_CUSTOM from millis(). platformio.ini: flash declared 16 MB with default_16MB.csv (two 6.5 MB OTA slots; NVS unchanged so the cached gauge config survives), stale -mfix-esp32-psram-cache-issue and include paths removed. Waveshare's page adds nothing new for firmware (Arduino core 2.0.x, LVGL 8.3.7 demo, 800 mA LDO); no operating-temperature figure. Built and flashed COM13. Updated esp32-s3-lcd-1-3, open-questions #8, index; root CLAUDE.md and README.