Files
ESP32-S3-Touch-LCD-5B/wiki/sources/launch-capture-2026-09-23.md
T
julian 6bdf4d43a9 Launch capture: decode rail pressure (service 2C, bar = raw x 0.03)
- capture-with-Launch session: live data on this DDE comes via KWP service
  2C (2C 10 00 DF -> 6C 10 HHLL), not the 22 D1xx identifiers (absent) or
  the session-gated 21 blocks
- rail pressure actual VERIFIED two-point vs the Launch display:
  bar = HHLL x 0.03 (idle ~305, 2500 rpm ~430)
- recipe now generalises to any Launch-visible value; self-poll needs the
  session/define handshake (captured, deferred design decision)
- wiki: sources/launch-capture-2026-09-23.md, obd-diagnostic-polling,
  open-questions #7, index; raw serial capture (~13 MB)

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-09-23 16:48:10 +02:00

3.3 KiB
Raw Blame History

type, tags, updated
type tags updated
source
can-bus
obd
dde
kwp2000
launch
rail-pressure
live-data
capture
2026-09-23

Launch live-data capture — rail pressure decoded (2026-09-23)

The capture-with-Launch session that obd-diagnostic-polling had been pointing at since July, finally run. Engine idling, our read-only logger (tools/serial_logger.py) on Controller A's USB recording the full CANRAW stream while the Launch polled the DDE; then the user selected Rail Pressure (actual) and blipped to 2500 rpm for a second calibration point. Raw: raw/serial-COM10-20260923-163511.log (~13 MB, both halves of every exchange).

Headline: rail pressure actual is decoded and VERIFIED

(verified 2026-09-23, two operating points against the Launch display)

Direction CAN ID Payload Meaning
Launch → DDE 0x6F1 12 04 2C 10 00 DF target 12 (DDE), 4-byte req, service 2C local-id 10, operand 00 DF
DDE → Launch 0x612 F1 04 6C 10 HH LL 6C = 2C+0x40, id 10, then 16-bit rail value HHLL

Rail pressure (bar) = (HH·256 + LL) × 0.03 — linear through zero, no offset.

Calibration points (sustained, not transient):

  • idle: raw 0x27EF (10223) → 307 bar vs Launch ~305 ✓
  • 2500 rpm: raw 0x3768 (14184) → 425 bar vs Launch ~430 ✓
  • factor from the two points: 0.0298 and 0.0303 → adopt 0.03 bar/count (≈ raw / 33.3)

Transient spikes to 0x4E31 (20017 → 600 bar) occurred at the instant of throttle tip-in (rail overshoot); they are real but not the steady value the gauge reads.

How the Launch reads it — the mechanism (observed, semantics unverified)

Not the simple 21/22 identifier reads the diag-route-b-2026-09-23 blind scan tried (those NRC'd — session/security gated). The live poll is service 2C (KWP dynamicallyDefineLocalIdentifier family): on connect the Launch sends 2C 10 15 E0 once (define), then polls 2C 10 00 DF repeatedly (~200 ms), each returning a fresh 6C 10 HHLL. So the value ID 00 DF is the rail-pressure block. Interpreting 00 DF / 15 E0 as memory addresses vs block numbers is unconfirmed — for replay only the request bytes matter. The Launch also runs a constant 1A 80 ident keep-alive and did 23 (readMemoryByAddress) reads on connect (ident/programming data, ASCII "090" etc.).

Consequences

  • The method generalises: any value the Launch will display can be decoded the same way — capture the 2C/6C pair while its screen shows the number, calibrate scale against the display at two points. Boost, MAF, injection quantity, EGTs are each one session away. See obd-diagnostic-polling "Beyond the probe".
  • Decode ≠ self-poll. Replaying 2C 10 00 DF ourselves needs the connect-time session/define handshake first (2C 10 15 E0, and the session the blind 21 scan showed is required). Stepping a running DDE into a diagnostic session is a transmit-on-the-bus design decision, not something the read-only probe does today. The bytes to do it are in this log if we choose to.
  • No EGS traffic (0x618) — only the DDE (0x612) answered; the Launch was on an engine page.

obd-diagnostic-polling · diag-route-b-2026-09-23 · diag-route-a-2026-09-23 · bmw-m57n-engine · open-questions