CANNY 5.3 pico vs ESP32-S3: driving the Patrol cluster

Why the user's old CANNY-based setup moves the Patrol tach and our ESP32 (Inst. Cluster, IO7) does not. Researched 2026-09-22 after the first in-car test of the dual-controller rig: temp needle parked mid-scale, tach dead (dual-controller-architecture).

The working reference setup (verified)

The user previously drove this same instrument cluster with a CANNY 5.3 pico (Russian visual-PLC automotive controller, cannylogic.com / canny.ru), using "Default Negative Output" in DIO mode on IO channel 8 (contact 4 — the channel that also carries the high-resolution PWM function). The cluster's needles respond in that setup — this is our known-good electrical reference.

What the CANNY output stage is (source: cannylogic.com/docs/c53pico, canny.ru)

  • Channels are 12 V-domain: "output operating voltage on the controller channels matches the supply voltage" (7–16 V, 18 V abs max).
  • Each channel is a configurable-polarity switch: "positive" mode connects the line to +12 V (high-side source), "negative" mode connects the line to GND (low-side sink). Two strengths: weak ~1 mA (pull) and strong 100 mA.
  • Rated for inductive/resistive/capacitive loads, 100 mA per channel, 300 mA total, automatic shutoff on over-current.
  • "Negative output" therefore produces the classic automotive sender signal: the line is pulled to ground when active and floats up to the cluster's own internal pull-up (~battery) when released — a 0 ↔ ~12 V swing without the controller ever sourcing voltage.

What our ESP32-S3 GPIO is

  • 3.3 V push-pull logic pin, absolute max ~3.6 V, source/sink a few tens of mA, no protection (unverified — standard ESP32-S3 datasheet values).
  • LEDC PWM on B's IO7 (tach square wave) and IO8 (temp duty) drives the line actively to 3.3 V and 0 V (repo).

Why this explains the test-day symptoms (verified 2026-09-22 for the tach — needle tracks rpm through the 2SK3069 low-side stage; see [[patrol-instrument-cluster]] for calibration)

  • The Patrol tach input expects negative-going pulses on a line it pulls up internally toward battery. With the ESP32 push-pull output attached, the "high" half of every cycle is 3.3 V instead of ~12 V — likely below the input threshold, so the tach sees no edges at all → dead needle, exactly what the CANNY's negative output provides and we don't.
  • The temp gauge input is a sender-resistance-to-ground circuit. A 3.3 V push-pull PWM can bias it to some fixed effective level — a needle that parks at one position and ignores duty changes is consistent with this (mid-scale at 89 °C may have been coincidence, not the duty law working). Re-test after the drive stage is fixed before trusting the temp calibration in dual-controller-architecture.
  • It is not PWM polarity in firmware: a 50 % square wave is its own inverse, and inverted temp duty would move the needle backwards, not freeze it.

The fix (per channel): replicate "negative output"

Small low-side switch between the ESP32 pin and the gauge line:

gauge line ──────────────┬──── (cluster's internal pull-up to ~12 V)
                         │
                    D (drain/collector)
ESP32 IOx ──[R ~1k]── G/B   N-MOSFET (logic-level, e.g. 2N7002/AO3400) or NPN (2N2222 + base R)
                    S (source/emitter)
                         │
                        GND (common with cluster!)
  • ESP32 high → line pulled to GND; ESP32 low → line released to the cluster's pull-up. This inverts the logic: tach unaffected (50 % square), temp duty becomes 255 − duty at the gauge — recalibrate temp_slope/temp_offset (dual-controller-architecture tunables) or invert in B's firmware.
  • If the cluster input turns out to have no internal pull-up, add an external ~4.7–10 kΩ to +12 V.
  • On hand (2026-09-22): a 2SK3069 (N-ch, 60 V / 75 A, 4 V-drive class) — hugely oversized but suitable; planned for the tach channel with 220 Ω gate series + 10 kΩ gate pulldown (source: alltransistors.com 2SK3069).
  • Never connect the 12 V-pulled gauge line directly to an ESP32 pin, including in open-drain mode — the pin is not 12 V tolerant.
  • Grounds must be common: cluster GND ↔ Inst. Cluster GND.

Open items

  • Scope or multimeter the tach line at rest: does it float high (~12 V) with nothing attached? Confirms the internal pull-up assumption.
  • After the transistor stage: re-run the override test (Force tach rpm / Force coolant duty on A's tuning screen) and re-derive the temp duty law; promote this page's hypothesis to (verified).

dual-controller-architecture · nissan-patrol-swap · open-questions