# Launch live-data capture — rail pressure decoded (2026-09-23)
The capture-with-Launch session that [[obd-diagnostic-polling]] had been pointing at since July, finally run. Engine idling, our read-only logger (`tools/serial_logger.py`) on Main CTRL's USB recording the full `CANRAW` stream while the Launch polled the DDE; then the user selected **Rail Pressure (actual)** and blipped to 2500 rpm for a second calibration point. Raw: `raw/serial-COM10-20260923-163511.log` (~13 MB, both halves of every exchange).
## Headline: rail pressure actual is decoded and VERIFIED
**`(verified 2026-09-23, two operating points against the Launch display)`**
| Direction | CAN ID | Payload | Meaning |
|---|---|---|---|
| Launch → DDE | `0x6F1` | `12 04 2C 10 00 DF` | target `12` (DDE), 4-byte req, service `2C` local-id `10`, operand `00 DF` |
| DDE → Launch | `0x612` | `F1 04 6C 10 HH LL` | `6C` = `2C`+0x40, id `10`, then **16-bit rail value `HHLL`** |
**Rail pressure (bar) = (HH·256 + LL) × 0.03** — linear through zero, no offset.
Calibration points (sustained, not transient):
- idle: raw `0x27EF` (10223) → 307 bar vs Launch **~305** ✓
- 2500 rpm: raw `0x3768` (14184) → 425 bar vs Launch **~430** ✓
- factor from the two points: 0.0298 and 0.0303 → adopt **0.03 bar/count** (≈ raw / 33.3)
Transient spikes to `0x4E31` (20017 → 600 bar) occurred at the instant of throttle tip-in (rail overshoot); they are real but not the steady value the gauge reads.
## How the Launch reads it — the mechanism `(observed 2026-09-23)`
The live poll is **service `2C`** (KWP dynamicallyDefineLocalIdentifier family): on connect the Launch sends `2C 10 15 E0` once (define), then polls `2C 10 00 DF` repeatedly (~200 ms), each returning a fresh `6C 10 HHLL`. So the value ID `00 DF` is the rail-pressure block. Interpreting `00 DF` / `15 E0` as memory addresses vs block numbers is unconfirmed — for replay only the request bytes matter. The Launch also runs a constant `1A 80` ident keep-alive and did `22`/`23` (readData / readMemoryByAddress) reads on connect (ident/programming data, ASCII `"090"` etc.).
### Services the Launch used — and did NOT use `(verified from the full capture)`
Every `0x6F1` request in the ~13 MB log, by service: **`1A`** (ident keep-alive), **`2C`** (live-data define/read), **`22`/`23`** (connect-time ident/memory), plus flow control. **Absent entirely: `10` StartDiagnosticSession, `27` SecurityAccess, `3E` TesterPresent.**
This is the key operational finding: **rail pressure is served in the DDE's default state — no diagnostic session, no security seed/key, no tester-present keep-alive.** The earlier `21 xx` NRCs (0x22 conditions-not-correct, 0x33 security-denied) in [[diag-route-b-2026-09-23]] were specific to the `21` read-by-local-id mechanism — a *different door* — and do **not** apply to the `2C` path. There is no secret algorithm between us and this value.
## Consequences
- **The method generalises**: any value the Launch will display can be decoded the same way — capture the `2C`/`6C` pair while its screen shows the number, calibrate scale against the display at two points. Boost, MAF, injection quantity, EGTs are each one session away. See [[obd-diagnostic-polling]] "Beyond the probe".
- **Self-poll is feasible without any secret.** To read rail pressure ourselves: send the one-time define `2C 10 15 E0`, then poll `2C 10 00 DF` → parse `6C 10 HHLL`. **No `10` session, no `27` security, no `3E` tester-present required** (proven above). The only barriers are our own choices, not the ECU's — see the two below.
- **It is still a transmit-on-the-bus action, and `2C` is not strictly read-only** (it writes a definition into the ECU's dynamic-identifier table — harmless, but a state change). So it stays outside the current probe whitelist by policy.
- **Intended home (design decision, 2026-09-23):** any active polling belongs behind a **password-protected "Diagnostics" screen** on Main CTRL — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records [[open-questions]]; not built yet.
- No EGS traffic (`0x618`) — only the DDE (`0x612`) answered; the Launch was on an engine page.
## Related