Files
ESP32-S3-Touch-LCD-5B/docs/UART_PROTOCOL.md
T
julian f60bdac268 Link protocol v2, ESP-NOW leg, gauge tunables + tuning screen; remove Home screen
Protocol v2 (shared header, byte-identical with the 1.3 repo):
- typed DATA/CONFIG frames: 0xAA | ver | type | len | payload | XOR | 0x55
- gear split into lever (P/R/N/D/S/M) + target/engaged nibbles, engine rpm,
  alert bitmap decided here from tunable thresholds, link_config_t tunables
- docs/UART_PROTOCOL.md rewritten for v2

Controller A modules:
- tunables: gauge calibration + alert thresholds in NVS, 'cfg' serial console,
  bench override (never persisted)
- espnow_link: every frame also broadcast on ESP-NOW ch 1; radio stays in STA
  (WiFiManager no longer powers it off)
- uart_manager: DATA at 5 Hz + CONFIG on change/5 s on both transports
- can_driver: publishes gear pieces and rpm, evaluates alerts
- tuning_screen: hand-coded Gauge Tuning page (swipe right from Driveline),
  -/+ rows, enable switches, override sliders, Driveline/Defaults buttons

UI: SquareLine Home screen (3 meters + battery) and meters_manager removed;
Driveline is the boot screen; Settings back-gesture calls app_show_driveline().

tools/fix_penv_deps.ps1: repairs the shared PlatformIO penv after a 1.3 build.
Bench-verified with Controller B: both transports alive, dedupe, override
rpm 2000 -> 133.3 Hz tach output.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-09-21 19:12:31 +02:00

6.0 KiB
Raw Blame History

Link Protocol Specification (v2)

Version: 2 (PACKET_VERSION 0x02) Last Updated: 2026-09-21 Source of truth: include/protocol/automotive_data.h — byte-identical in both repos. Direction: Controller A (ESP32-S3-Touch-LCD-5B) → Controller B (ESP32-S3-LCD-1.3), one way.


Transports

The same frames are sent on two paths at once. B accepts either and deduplicates DATA frames on packet_id + timestamp_ms.

Path A side B side Notes
UART1 GPIO 44 TX → SP3485 → terminal 485_A / 485_B IO1 RX (left header pin 4) 115200 8N1. Bench: 485_A straight into IO1 + GND works (unterminated, biased high). Car: RS485 transceiver on B, or rely on ESP-NOW.
ESP-NOW broadcast, Wi-Fi channel ESPNOW_CHANNEL (1) listens; hops channels 1–13 while silent, locks when frames arrive A's radio stays in STA mode permanently. If A joins an access point the channel follows the AP; B finds it by hopping.

Frame format (both transports)

0xAA | version | type | length | payload[length] | checksum | 0x55
Field Size Value
start 1 0xAA
version 1 0x02 — B rejects any other value (counted as version error)
type 1 0x01 DATA, 0x02 CONFIG
length 1 payload bytes (21 for DATA, 27 for CONFIG)
payload length see below, little-endian, packed
checksum 1 XOR of version, type, length and every payload byte
end 1 0x55

DATA frame = 27 bytes, CONFIG frame = 33 bytes. Helpers: frame_build(), frame_parse() in the header.


DATA payload — automotive_data_t (21 bytes, every 200 ms)

Offset Size Field Unit / encoding
0 1 packet_id rolling counter
1 4 timestamp_ms A's millis()
5 1 gear_lever gear_lever_t: 0 P, 1 R, 2 N, 3 D, 4 S, 5 M, 0xFF unknown
6 1 gear_nibbles high nibble = gearbox target gear (CAN 0x0BA), low nibble = engaged gear (CAN 0x1D2 byte 1); 0 = none/P/R/N, 1–6 forward gears. target != engaged ⇒ shift in progress
7 2 engine_rpm 1/min (CAN 0x0AA)
9 2 gearbox_oil_temp 0.1 °C signed
11 2 engine_oil_temp 0.1 °C signed — no sensor on this M57N, never valid
13 2 coolant_temp 0.1 °C signed
15 2 battery_voltage 0.01 V
17 2 alerts bitmap, decided on A (below)
19 1 valid_flags bitmap (below)
20 1 debug_enabled 0/1, B mirrors A's debug overlay toggle

valid_flags: bit0 gear, bit1 gearbox temp, bit2 engine oil temp, bit3 coolant, bit4 battery, bit5 alerts, bit6 rpm. A field is meaningful only when its bit is set. On the bench without CAN, A sends default temperatures/voltage marked valid but never marks rpm or gear nibbles valid.

alerts (thresholds come from A's tunables):

Bit Name Condition
0 ALERT_GEAR_MISMATCH lever (0x1D2) and gearbox target (0x0BA) disagree beyond the debounce
1 ALERT_COOLANT_HOT coolant ≥ coolant_hot_c
2 ALERT_GEARBOX_HOT gearbox oil ≥ gearbox_hot_c
3 ALERT_GEARBOX_COOLING gearbox's own cooling demand (0x0B5 ST_OTMP_GRB ≥ 1)
4 ALERT_BATTERY_LOW battery < battery_low_x100

Severity for display: bits 0, 1, 2, 4 are red alarms; bit 3 is amber.


Tunables edited on A (serial console cfg ..., NVS-backed), executed on B's gauge outputs.

Field Size Default Meaning
cfg_version 1 1 bumped on every change; B applies when it changes
tach_ppr 1 4 tach pulses per engine revolution
tach_trim_pct 1 0 fine trim −50…+50 %
tach_min_hz 2 0 0 = no clamp
tach_max_hz 2 600 0 = no clamp
temp_pwm_hz 2 1000 coolant PWM frequency
temp_slope_x100 2 150 duty per °C ×100
temp_offset 2 50 duty at 0 °C
temp_min_c 2 40 output off below this coolant temperature
temp_duty_max 1 255 clamp
out_enable 1 0x03 bit0 tach, bit1 temp
override_mode 1 0 bit0 force tach rpm, bit1 force temp duty (bench tool, never persisted)
override_rpm 2 0
override_duty 1 0
coolant_hot_c 2 100 alert threshold
gearbox_hot_c 2 130 alert threshold
battery_low_x100 2 1100 alert threshold (0.01 V)

Coolant duty law: duty = temp_slope_x100 × T°C / 100 + temp_offset, clamped to 0…temp_duty_max, 0 while T < temp_min_c. Defaults reproduce the user's earlier CANNY program (1.5·T + 50).

Tach: f = rpm × tach_ppr / 60 × (1 + trim/100), clamped, 50 % duty. Output low when rpm is invalid, zero, the link is down, or the output is disabled.


Controller A console commands (USB serial)

cfg show
cfg set <name> <value>    tach_ppr tach_trim tach_min_hz tach_max_hz
                          temp_hz temp_slope temp_offset temp_min temp_duty_max
                          tach_en temp_en coolant_hot gearbox_hot batt_low
cfg override off | rpm <n> | duty <n> | both <rpm> <duty>
cfg reset

set values are saved to NVS and pushed to B immediately. override is pushed but not saved on either side.

The same tunables are editable on A's touchscreen: Home → swipe right → Driveline → swipe right → Gauge Tuning (−/+ per field, enable switches, override sliders).


Receiver behaviour (B)

  • Link considered lost after 1000 ms without an applied DATA frame on any transport; display shows N/A and both gauge outputs go low.
  • Gear label: letter from gear_lever; digit = engaged gear, or the target gear (pulsing) while target ≠ engaged.
  • Icons turn red from the alerts bits, never from local thresholds.
  • Last CONFIG is cached in B's NVS so a B reboot drives the gauges before A resends.

Changing the protocol

  1. Edit automotive_data.h on A, bump PACKET_VERSION.
  2. Copy the header to B unchanged.
  3. Update this document.
  4. Flash both. A stale B logs version errors and applies nothing.