d7b17d9cb2
One FastAPI process on port 9000 (the charger's hardcoded URL), replacing
discovering/station.py for production:
- csms.py: OCPP 1.6J handlers ported from the proven discovery code; the
decide() gate now supports per-gun RFID restriction ("connectors": [2])
enforced at StartTransaction
- users.py: username/password auth (PBKDF2), stateless HMAC sessions
(cookie + bearer, 30 days), fnmatch permission scopes
(charger:<cp>:<gun>, relay:<name>, admin) and a user CLI
- relays.py: local tinytuya control of the SmartLife/Tuya WiFi relays
(no cloud; needs one-time id/local-key extraction via tinytuya wizard)
- store.py: SQLite consumption tracking — who charged, when, how many kWh,
per-minute energy/power/SoC samples; tx ids survive restarts
- routes.py: /api/* with per-scope checks, allowlist/user CRUD, runtime
learn-mode flip, session history with visibility rules
- static/: self-contained vanilla-JS PWA — login, per-gun start/stop gated
by scope + gun readiness, relay toggles, history, admin tab
config.json (password hashes, session secret, Tuya keys) and sessions.db
are gitignored; config.example.json documents the shape. Covered by a
37-check smoke test incl. a fake charge point over the real WS route.
11 lines
188 B
Plaintext
11 lines
188 B
Plaintext
# Runtime state + secrets (Tuya local keys live in config.json)
|
|
config.json
|
|
events.jsonl
|
|
seen_tags.json
|
|
sessions.db
|
|
discovery_*.json
|
|
snapshot.json
|
|
tinytuya.json
|
|
devices.json
|
|
tuya-raw.json
|