backend.db (renamed from sessions.db) now holds everything: the sessions
and samples tables plus a settings table with the app-state sections
(users, allowlist, relays, chargers, learn_mode, session_secret) as JSON
blobs. All mutations go through the API/panel and take effect immediately;
there is no config file and no hand-edit-then-restart ambiguity.
- legacy config.json auto-imports into the db on first start (renamed to
config.json.migrated as a backup)
- new admin endpoints: PUT/DELETE /api/relays/{name} (how tinytuya wizard
results are registered now) and PUT /api/chargers/{cp_id} (panel labels)
- BACKEND_DB env override so tests run on an isolated temp database
- smoke test: 45 checks, real db verified untouched
5.1 KiB
type, updated, tags
| type | updated | tags | |
|---|---|---|---|
| meta | 2026-07-11 |
|
Overview — Anfu Home Charger OCPP Project
Goal: a private, self-hosted ocpp backend (CSMS) for a home EV charger. No billing, no public charging. Authorization via existing RFID cards ✅ and a mobile-friendly web app reached over netbird (by-vehicle ❌ closed — firmware never forwards a vehicle id). Scope expanded 2026-07-11: the same backend also controls the household wifi-relays, locally via tinytuya.
Current state (2026-07-11)
Connectivity: ✅ solved. The jc-6620 controller inside the anfu-charger reliably dials out to the CSMS — verified both on the charger's own LAN (192.168.2.114:9000) and across the NAT boundary on the WAN subnet (10.0.10.203:9000). Getting here required the fixes catalogued in troubleshooting; the network layout is in network-topology.
Software: production backend built (2026-07-11), including the web panel. station.py was ported into the ../backend/ package: one FastAPI process on port 9000 = CSMS WebSocket + /api/* (charger control, allowlist CRUD, runtime learn-mode flip) + wifi-relays on/off/toggle + multi-user auth (username/password, per-resource scopes: gun 1 / gun 2 / per-relay / admin, per-gun-restrictable RFID cards — authorization) + consumption tracking (SQLite: who charged, when, how many kWh, per-minute meter samples) + the PWA control panel at / (login, scope-filtered start/stop buttons, relay toggles, history, admin). Smoke-tested (45 checks incl. a fake charge point over the real WS route); ✅ live charger connects to it since 2026-07-11 evening; ⚠️ panel untested from a real phone. All state lives in one SQLite file (backend.db) — no config file, every change via API/panel takes effect immediately. The csms-toolkit (../discovering/) remains as diagnostic tooling.
Capabilities: ✅ known. The live probe (2026-07-09-discovery-eu092025) identified the pile as SimpleCharge "MultiSocketCharger" (fw 1.24.0620.1, OCPP ID eu092025) with two guns, RemoteTrigger (verified), SmartCharging, Reservation, a 6-entry local auth list, and per-minute meter data including SoC. Only Autocharge remains unknown (physical test pending; MacEnabled is a lead — authorization).
Authorization: 2 of 3 methods ✅ verified live (2026-07-09 test session, both cars plugged, both guns charging simultaneously):
- RFID ✅ — card
…393tapped → Authorize → real charging session on gun 2 (DC, ~26 kW avg, 1.8 kWh delivered). Card enrolled as "RFID card A". - Remote (app path) ✅ — RemoteStart and RemoteStop both Accepted and executed on gun 1;
app-remotetoken enrolled. - By vehicle ❌ closed — three escalating tests (plain plug-in,
MacEnabled=truelive,MacEnabled=trueafter power-cycle) all negative; this firmware never forwards a vehicle ID over OCPP (authorization).
Hardware surprise: this is a DC-capable multi-standard charger (gun 1 EU, gun 2 Chinese GB/T @ 30 kW), not the assumed basic AC unit — see anfu-charger.
What's next
Cut the live charger over to the backend— ✅ done 2026-07-11 evening:eu092025connects topython -m backend.main(verified in events.jsonl). Remaining: a card tap + a panel button-push on the live charger.- Create the real users —
python -m backend.users add <name> --scopes ...for each household member (the API stays open until the first user exists). - Extract the Tuya local keys (
tinytuya wizard— steps in wifi-relays) and register them viaPUT /api/relays/<name>→ relays become controllable. - Flip learn mode off — both cards + the app token are enrolled; switchable from the panel's Admin tab or
POST /api/mode?learn=false, no restart. (Only wait if more cards need tapping.) - Test the panel from a phone — it's built and serving at
http://<host>:9000/; verify login, a real button-push start on a ready gun, and add-to-home-screen over netbird. - Resolve the ❓ remote-stop restart question — did the gun-2 session auto-restart from auth cache after RemoteStop, or was the card re-tapped? Affects the app's Stop button UX (authorization).
Open decisions ❓
| Decision | Options | Status |
|---|---|---|
| Always-on host for CSMS + app | LAN PC · the 10.0.10.203 machine · dedicated box (e.g. Pi on charger LAN, joined to NetBird) |
open — now also needs subnet reachability to the [[wifi-relays |
| Web app auth | — | ✅ resolved 2026-07-11: username+password login with per-resource scopes (gun 1 / gun 2 / per-relay / admin) — see authorization. Bootstrap: create the first admin user via python -m backend.users add |
| Autocharge / by vehicle | — | ❌ closed 2026-07-09: not supported by this firmware (authorization) |
| Host IP stability | static IP · DHCP reservation | open (required either way — touchscreen URL is hardcoded) |
Sources
- 2026-07-09-findings-and-requirements — the founding findings/requirements doc