2e5960fae3
- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md. - Ingested findings and requirements document into the wiki. - Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting. - Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit. - Established configuration files for Obsidian app settings and workspace layout. - Implemented core plugins and appearance settings for the wiki.
107 lines
5.6 KiB
Markdown
107 lines
5.6 KiB
Markdown
# Anfu Home Charger — OCPP Integration: Findings & Requirements
|
||
|
||
_Last updated: 2026-07-09_
|
||
|
||
## 1. Goal
|
||
|
||
Run a **private, self-hosted OCPP 1.6J backend (CSMS)** for a home EV charger.
|
||
No billing, no public charging. Authorization should be possible via:
|
||
|
||
1. **RFID cards** already owned (tap to charge).
|
||
2. **By vehicle / chassis**, if the hardware supports it (see §7 — has a caveat).
|
||
3. A **mobile / web app** (start/stop charging), hosted securely behind an existing
|
||
**NetBird** private network.
|
||
|
||
## 2. Hardware & Topology
|
||
|
||
The charging pile contains three networked devices behind its own router:
|
||
|
||
```
|
||
10.0.10.0/24 (upstream / WAN — main gateway lives here)
|
||
│
|
||
┌──┴───────────────┐
|
||
│ Four-Faith router │ WAN gets a 10.0.10.x address; NAT boundary
|
||
└──┬───────────────┘
|
||
│ LAN = 192.168.2.1 (mask 255.255.255.0)
|
||
├── 192.168.2.228 JC-6620 OCPP communication controller ← the OCPP client
|
||
├── 192.168.2.118 EV charging controller (main control board), DHCP
|
||
└── 192.168.2.114 maintenance PC (LAN side)
|
||
```
|
||
|
||
- Wiring is the manufacturer's **star** topology: the EV charging controller **and** the
|
||
JC-6620's fixed-IP (right) port each connect to a router LAN1–4 port.
|
||
- **The JC-6620 (192.168.2.228) is the device that opens the outbound OCPP WebSocket**
|
||
to the CSMS. It talks to the EV controller locally on port **2403**.
|
||
|
||
## 3. CSMS software (this repo)
|
||
|
||
| File | Purpose |
|
||
|------|---------|
|
||
| `csms.py` | Minimal OCPP 1.6J server — accepts everything, logs raw frames. Discovery/tester. |
|
||
| `rawlisten.py` | Dumb TCP listener on :9000 — shows whether *any* bytes arrive. Fallback diagnostic. |
|
||
| `station.py` | **The real controller.** Allowlist-based auth + "learn mode" + hooks for remote start/stop. |
|
||
| `station_config.json` | `{ "learn_mode": bool, "authorized": { "<idTag>": {name, kind} } }` |
|
||
| `seen_tags.json` | Auto-recorded log of every idTag observed (for discovery). |
|
||
|
||
Runtime: Python venv with `websockets` (16.0) + `ocpp`. Server listens on
|
||
`ws://0.0.0.0:9000/<chargePointId>`.
|
||
|
||
## 4. Charger-side configuration (touchscreen)
|
||
|
||
- **General Settings → Charger INEO:** `URL = ws://<CSMS-IP>:9000`, `ChargerID = <any>`
|
||
- **Back Office → Universal:** `Billing Mode = BackgroundBilling`,
|
||
`Communication Method = Ethernet`, `JC-6620 IP = 192.168.2.228`, `Port = 2403`
|
||
- **JC-6620 network config (静态 IP):** IP `192.168.2.228`, mask `255.255.255.0`,
|
||
**default gateway (默认网关) `192.168.2.1`** (DNS not needed — CSMS is a bare IP).
|
||
|
||
## 5. Findings / gotchas (hard-won — check these first if it breaks)
|
||
|
||
1. **CSMS host firewall** must allow inbound **TCP 9000**. Windows silently drops
|
||
otherwise → looks like "charger never connects."
|
||
2. **`Billing Mode` must be `BackgroundBilling`.** Until it is, the OCPP client never
|
||
dials out *at all* (zero TCP SYNs). This was the blocker for the first connection.
|
||
3. **`Communication Method` must be `Ethernet`** (not 4G/SIM).
|
||
4. **URL / network changes require a pile power-cycle** to take effect.
|
||
5. **JC-6620 default gateway must be `192.168.2.1`.** It shipped as `192.168.2.228`
|
||
(pointing at itself) — which reaches a *same-subnet* CSMS but **cannot route to the
|
||
WAN**. This is why a `192.168.2.x` CSMS worked but a `10.0.10.x` CSMS did not, until
|
||
the gateway was fixed.
|
||
6. **No port-forwarding needed on the charger router.** The JC-6620 is the *client* and
|
||
dials outbound; NAT handles LAN→WAN. Port-forwarding would only matter for inbound.
|
||
7. **The CSMS host needs a stable IP.** The touchscreen URL is hardcoded, so the host
|
||
must not change address (static IP or a DHCP reservation).
|
||
|
||
## 6. Verified working
|
||
|
||
- ✅ **Local CSMS** at `192.168.2.114:9000` — JC-6620 connected, full BootNotification
|
||
exchange.
|
||
- ✅ **Remote / WAN CSMS** at `10.0.10.203:9000` (on the router's WAN subnet) — connected
|
||
after fixing the JC-6620 default gateway. Confirms the CSMS can live upstream / off-subnet.
|
||
|
||
## 7. Requirements to build next
|
||
|
||
All three authorization methods funnel through one gate in `station.py` —
|
||
`decide(id_tag)` → Accepted/Rejected against the allowlist. So the build is:
|
||
|
||
- **Allowlist enforcement** — already implemented. Learn mode captures ids; flip
|
||
`learn_mode=false` to enforce.
|
||
- **RFID cards** — tap each card once in learn mode, harvest its idTag from
|
||
`seen_tags.json`, add to `authorized` with a name. Works with existing cards.
|
||
- **By vehicle / chassis** — ⚠️ **needs a physical test.** True VIN / Plug & Charge
|
||
(ISO 15118) is unlikely on a basic AC unit. The lighter option is **Autocharge**: some
|
||
chargers auto-send a per-vehicle idTag on plug-in (no card). Test = plug car in without
|
||
tapping; if a stable idTag appears in `seen_tags.json`, whitelist it as `kind:"car"`.
|
||
If nothing appears, "by chassis" is not achievable on this hardware.
|
||
- **Mobile / web app** — a web control panel (mobile-friendly, no app store) exposing
|
||
Start/Stop via OCPP `RemoteStartTransaction` / `RemoteStopTransaction`, plus live status
|
||
and clickable allowlist management. Bind to `0.0.0.0`, reach it over **NetBird**.
|
||
Optional access token/PIN for defense-in-depth.
|
||
|
||
## 8. Open decisions (for you)
|
||
|
||
- **Final host** for the always-on CSMS + app: the LAN PC, the `10.0.10.203` machine, or
|
||
a dedicated always-on box (e.g. a Pi on the charger LAN joined to NetBird)?
|
||
- **Web app auth:** rely on NetBird network isolation only, or also require a PIN/token?
|
||
- **Autocharge:** do we run the plug-in test to see if "by chassis" is even possible?
|
||
- **IP stability:** static IP vs DHCP reservation for the chosen host.
|