docs(wiki): DT-008 card-technology findings, box leaflet source, install checklist; add scripts/reader-sink.py

Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only)
although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as
unresolved with the EM4100 test that settles it (open question #18). Phone taps give a
random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID
bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification
checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink
answering the push with the SDK verdict and Connection: close.

Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
This commit is contained in:
2026-09-17 09:47:40 +02:00
parent 5afdcc78ae
commit 4d1d245680
7 changed files with 290 additions and 5 deletions
+80 -3
View File
@@ -2,7 +2,7 @@
type: entity
tags: [parking, hardware, readers, qr, dingtian]
sources: [dingtian-dt008]
updated: 2026-07-04
updated: 2026-09-17
status: open
---
@@ -25,8 +25,9 @@ or RFID [[subscription]]** credentials. Product page: dingtian-tech.com/en_us/qr
- **QR/barcode + card.** Reads **QR / simple barcode** AND **ID/IC/NFC cards** (~0.2 s, 0–10 cm).
(An earlier note guessed "ER80-EM = 125 kHz EM4100 prox" — that was part of the same mis-id.)
- **Interfaces: Wiegand 26/34, TCP/IP, USB, RS485.** (NOT RS-232 — that was a fictional-datasheet
claim.) For our integration it talks **HTTP over TCP/IP**; Wiegand is the reader's *output line*
- **Interfaces: Wiegand 26/34, TCP/IP, USB, RS485** per the product page; the box leaflet
([[dingtian-dt008-box-manual]]) also lists **RS232**. (An earlier note dismissed RS-232 as a
claim from the mis-identified GEE PDF — withdrawn 2026-09-17.) For our integration it talks **HTTP over TCP/IP**; Wiegand is the reader's *output line*
on a valid read, not the host transport.
- **Power** 9–16 V DC, 800 mA; **86×86×42 mm**; −30…70 °C. Fits the [[disk-os-hardening|appliance]].
@@ -182,6 +183,82 @@ symbology except **QR + Code128** (all our credentials); if offered, set **minim
re-enables the phantom symbologies — re-apply after any reset/replacement. Physical fallback if any
noise survives: hood/visor the window, tilt it down, avoid facing the striped arm.
## ⚠️ Two units, two card sets, no overlap — 125 kHz vs 13.56 MHz (2026-09-17, unresolved)
The product page says the DT-008 reads "ID/IC/NFC cards" and the **box leaflet**
([[dingtian-dt008-box-manual]]) claims EM-ID, M1, ISO 14443A/B and ISO 15693 in one unit. Yet on
the bench 2026-09-17, with two card sets, the two units we own read **disjoint** sets:
| Unit | Serial family | Reads | Does not read |
| --- | --- | --- | --- |
| park-buzi entry/exit (bought 2026-06) | `H05M…` (`H05M2AFA`, `H05MA5B0`) | the site's enrolled cards (**125 kHz "ID"**, EM4100-class) | 13.56 MHz cards |
| lab unit (fresh, 2026-09) | `HC002721` | **13.56 MHz "IC/NFC"** cards (e.g. UID `A238BC`) | the park-buzi card set |
**The decisive test needs no hardware:** hold each card on an NFC-capable phone. A 13.56 MHz card
is detected; a **125 kHz card is invisible to a phone**. The lab reader and the phone agreed on
exactly the same set, and the other set was invisible to both — so the park-buzi set is 125 kHz and
the park-buzi readers are the 125 kHz variant. Card bodies help too: EM4100 / TK4100 / T5577 (often
a printed 10-digit decimal) = 125 kHz; Mifare / S50 / 1K / NTAG = 13.56 MHz.
Nothing in `QRCode_v1_6_5.exe` selects the frequency (no card-type field — see the screenshot in
[[site-device-installation]] §2).
**Why the lab unit does not read them is NOT settled** — the phone test only proves the park-buzi
cards are *not* 13.56 MHz. Three explanations remain, with different fixes:
1. **The park-buzi cards are 125 kHz but not EM4100** (HID Prox / Indala / AWID / a T5577 in a
non-EM format): invisible to a phone, not decoded by an EM-only front end, but read by the older
batch. Card bodies help: EM cards usually print a 10-digit decimal; HID cards carry the HID logo.
2. **The lab unit's 125 kHz front end is dead or disabled** — the leaflet says it should be there;
a firmware setting the v1.6.5 tool does not expose is possible.
3. **The leaflet is generic and units ship per variant** — the vendor can say from the two serials.
**Decisive test (cheap):** a known **EM4100 125 kHz card/keyfob** on the lab unit, held at 1–10 cm.
Reads → its 125 kHz radio works and the park-buzi cards are a different 125 kHz format (→ 1).
Does not read → unit defect or variant (→ 2/3, vendor with the serial). A USB keyboard-wedge
EM4100 reader (~10 €) additionally says outright whether the park-buzi cards are EM4100.
**Consequences (hold regardless of which explanation wins)**
- **A site's card stock and its readers must be proven together.** A card enrolled at park-buzi
is not readable by the lab unit today, whatever the reason; a replacement reader must be tested
against the site's actual cards **before** it ships, or every enrolled card is orphaned — same
class of trap as the `Card Input format`.
- **Purchase spec must name the card technology and format** the site uses (the serial family is
only a hint: `H05M…` reads park-buzi's cards, `HC…` does not). Ask the vendor (support address in
the tool's title bar) which card types a given serial decodes.
- **Bench testing park-buzi card problems on the lab unit is meaningless** until the lab unit is
shown to read the site's card type.
- **Open:** with a 13.56 MHz unit the native UID is 4 or 7 bytes, so `Card Input format = 6H`
truncates it — check on the lab unit which bytes survive and whether two cards can collide on the
6-hex value before enrolling anything against a 13.56 MHz reader ([[open-questions]]).
Record the variant on the site record next to the serial ([[site-device-installation]] §"Record").
**A phone is not a card (2026-09-17).** Tapping a phone on the 13.56 MHz unit beeps and logs a
*different* id every time (`18CA08`, `37F108`, `D5A908` three seconds apart). Read backwards
those are `08 CA 18`, `08 F1 37`, `08 A9 D5`: a first UID byte of **`08`** is the ISO 14443
marker for a **random UID**, which every phone in card-emulation mode generates per tap so that
readers cannot track the handset. So a phone can never be enrolled as an RF credential, and a
phone tap in the logs is not a clone attempt — just noise with a fresh id each time. Same for
cards with a "random ID" feature (DESFire / Mifare Plus in random-UID mode): if a card ever
enrolls but "stops matching", check whether its id changes between taps.
Incidentally this shows what **`6H` does on a 13.56 MHz unit**: the tool prints the **first three
bytes of the 4-byte UID, byte order reversed, fourth byte dropped**. Confirm against a card with
its UID printed on the body before enrolling; the dropped byte is the collision risk in
[[open-questions]] #18.
## Bench sink — `scripts/reader-sink.py` (2026-09-17)
A stdlib-only Python HTTP server that answers the push on any `/qa/mcardsea.*` path with the SDK
verdict (`--accept` → status 1 / two beeps, default status 0 / one beep), `Connection: close`, and
prints one line per read: time, source IP, `serial`, `dev`, `dir` (from the `status` low digit),
`ch` (from the `Q:`/`K:` prefix), `cardid`, path. Point the reader's *Server address / Server Port*
at the laptop (`python3 scripts/reader-sink.py -p 3000 --accept`, port 80 needs admin rights). Use it
to see the raw `cardid` a card yields, to prove a reader pushes at all, and to time the beep against
the reply. No app, no DB, no Docker.
## ⚠️ Reply MUST set `Connection: close` (verified on hardware)
The reader sends `Connection: keep-alive` but **only acts on the verdict (beep/output) once the TCP