docs(wiki): DT-008 card-technology findings, box leaflet source, install checklist; add scripts/reader-sink.py
Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only) although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as unresolved with the EM4100 test that settles it (open question #18). Phone taps give a random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink answering the push with the SDK verdict and Connection: close. Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
This commit is contained in:
+29
@@ -3322,3 +3322,32 @@ schema: health, ingest, stats, legacy row reads back with defaults); trainer `Ha
|
||||
kind", /health still 200); the collector's training proxy includes the trainer's error text. Pages:
|
||||
[[vision-review-outbox]] (incident + rule), [[bodytype-classifier-training]] (what the message
|
||||
means). Deploy: nothing manual — the new collector migrates on start.
|
||||
|
||||
## 2026-09-17 — DT-008 comes in two RF variants; cards are not portable between them
|
||||
|
||||
Bench finding: the fresh lab DT-008 (`HC002721`) reads a set of cards park-buzi cannot, and cannot
|
||||
read park-buzi's enrolled cards. NFC-phone test settled it: the phone and the lab reader detect
|
||||
exactly the same set (13.56 MHz), the park-buzi set is invisible to both (125 kHz). One radio per
|
||||
unit, no setting selects it, same model name. Rule: a site's readers, its card stock and any
|
||||
replacement unit must be the same variant; name the variant in the purchase spec and on the site
|
||||
record. Also recorded the tool's Setting-tab layout (three groups, each with its own Set button).
|
||||
Pages: [[dingtian-dt008-reader]], [[site-device-installation]] §2, [[index]].
|
||||
|
||||
## 2026-09-17 — phone taps on the DT-008 are random UIDs; what `6H` keeps
|
||||
|
||||
Three phone taps logged three ids ending in `08` — reversed, a first byte `08` = ISO 14443 random
|
||||
UID, so phones cannot be RF credentials. Side effect: `6H` on a 13.56 MHz unit prints the first three
|
||||
UID bytes reversed and drops the fourth. Pages: [[dingtian-dt008-reader]], [[open-questions]] #18.
|
||||
|
||||
## 2026-09-17 — box leaflet says the DT-008 reads every card type; "one radio per unit" downgraded
|
||||
|
||||
The leaflet in the lab unit's box ([[dingtian-dt008-box-manual]]) lists EM-ID, M1, ISO 14443A/B and
|
||||
15693 in one reader, so the earlier "two variants, one radio each" is now one of three explanations
|
||||
(variant / dead 125 kHz front end / non-EM 125 kHz cards at park-buzi). Decisive next test: a known
|
||||
EM4100 fob on the lab unit. Leaflet also lists RS232 — the old "not RS-232" dismissal is withdrawn.
|
||||
Pages: [[dingtian-dt008-reader]], [[site-device-installation]] §2, [[open-questions]] #18, [[index]].
|
||||
|
||||
## 2026-09-17 — `scripts/reader-sink.py`: a bench sink for the DT-008 push
|
||||
|
||||
Stdlib Python HTTP server answering the reader's GET with the SDK verdict + `Connection: close`,
|
||||
one log line per read (serial, dir, channel, cardid). Page: [[dingtian-dt008-reader]] §Bench sink.
|
||||
|
||||
Reference in New Issue
Block a user