docs(wiki): DT-008 card-technology findings, box leaflet source, install checklist; add scripts/reader-sink.py
Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only) although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as unresolved with the EM4100 test that settles it (open question #18). Phone taps give a random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink answering the push with the SDK verdict and Connection: close. Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
This commit is contained in:
@@ -0,0 +1,39 @@
|
||||
---
|
||||
type: source
|
||||
tags: [parking, hardware, readers, qr, rfid, dingtian, manual]
|
||||
sources: [dingtian-dt008-box-manual]
|
||||
updated: 2026-09-17
|
||||
---
|
||||
|
||||
# Source: DT-008 paper manual from the box ("QR Code Reader Technical Parameter")
|
||||
|
||||
Phone-scanned (OCR) from the leaflet packed with the fresh lab unit `HC002721`, 2026-09-17. Verbatim
|
||||
as OCR'd (typos are the OCR's):
|
||||
|
||||
```
|
||||
QR Code Reader Technical Parameter
|
||||
Voltage Support: DC 5V-16V
|
||||
Current: ≤0.75W
|
||||
Decoding support: QR code, one dimensional code
|
||||
Reading range: ID 1~10CM, IC 1~5CM
|
||||
Reading card type: EM-ID, M1, 15693, 125KHZ \ ISO14443A \ ISO14443B \ ISO15693
|
||||
Application environment: -10°C ~ 60°C
|
||||
Humidity: 10% ~ 90%
|
||||
Interface: Wiegand26, 34, RS485, RS232, [USB?]
|
||||
```
|
||||
|
||||
## What it claims that matters
|
||||
|
||||
- **All card technologies in one unit:** EM-ID (125 kHz), M1 = Mifare Classic (ISO 14443A),
|
||||
ISO 14443B, ISO 15693. Range differs by technology: **ID 1–10 cm, IC 1–5 cm**.
|
||||
- **RS232 is listed** — the earlier wiki position "NOT RS-232, that was a fictional-datasheet claim"
|
||||
came from the mis-identified GEE PDF; the box leaflet does list it. Irrelevant to us (HTTP push),
|
||||
but do not treat the interface list as evidence of a mis-id any more.
|
||||
- Power 5–16 V here vs 9–16 V / 800 mA on the product page ([[dingtian-dt008]]).
|
||||
|
||||
## What it does NOT settle
|
||||
|
||||
The lab unit does **not** read the park-buzi card set although the leaflet says it reads EM-ID —
|
||||
see [[dingtian-dt008-reader]] §"Two RF variants". Either the leaflet is generic for the line and
|
||||
units ship per variant, or the lab unit's 125 kHz front end is dead/disabled, or the park-buzi
|
||||
cards are a non-EM 125 kHz format (HID Prox / Indala / AWID) that only the older batch decodes.
|
||||
Reference in New Issue