Wiki pages written on 2026-10-24 but left uncommitted before the Windows to Linux migration: passage-confirmation concept, open question 20, deploy and query log entries, index line, incident and barrier page updates. Drops the stray tracked __pycache__ file. Line endings normalised to LF. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
1.4 KiB
1.4 KiB
type, tags, sources, updated
| type | tags | sources | updated | ||||
|---|---|---|---|---|---|---|---|
| concept |
|
|
2026-06-14 |
Safety Principle: A Barrier Is Not a Door
A vehicle barrier must not be driven as a timed "door open for N ms" by the application — a timed auto-close can drop a boom on a vehicle or person. (See parking-system-architecture §5.)
- Physical safety lives in the barrier operator's own firmware — induction loops, anti-crush, auto-reverse. (Recommended barrier operators in the bom are chosen because they own this.)
- The application and any relay board only ever express intent ("open"); they never time or
force a close against a vehicle. Reflected in the device-adapter-pattern's
pulseOpen. - Holds regardless of which relay device is used — uhppote-controller or esp32-custom-controller. The ESP32 design restates it: "the ESP32 only signals intent" (see fail-state-safety).
- Proposed revision, not repeal (2026-10-24): passage-confirmation asks to express a close after a vision-verified abandonment (driver reversed out, boom left up because the operator's sensor was never tripped). Still never timed, never blind: only with a fresh verdict, an empty lane in the tracker, and after bench tests that the operator's loop/photocell override the command. Until those tests pass on park-lab the rule stands unchanged.