Files
julian 580412aa50 wiki: passage-confirmation design and stage-73ada89 deploy notes (2026-10-24)
Wiki pages written on 2026-10-24 but left uncommitted before the Windows to
Linux migration: passage-confirmation concept, open question 20, deploy and
query log entries, index line, incident and barrier page updates. Drops the
stray tracked __pycache__ file. Line endings normalised to LF.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
2026-11-07 09:38:32 +01:00

1.4 KiB

type, tags, sources, updated
type tags sources updated
concept
parking
safety
devices
parking-system-architecture
2026-06-14

Safety Principle: A Barrier Is Not a Door

A vehicle barrier must not be driven as a timed "door open for N ms" by the application — a timed auto-close can drop a boom on a vehicle or person. (See parking-system-architecture §5.)

  • Physical safety lives in the barrier operator's own firmware — induction loops, anti-crush, auto-reverse. (Recommended barrier operators in the bom are chosen because they own this.)
  • The application and any relay board only ever express intent ("open"); they never time or force a close against a vehicle. Reflected in the device-adapter-pattern's pulseOpen.
  • Holds regardless of which relay device is used — uhppote-controller or esp32-custom-controller. The ESP32 design restates it: "the ESP32 only signals intent" (see fail-state-safety).
  • Proposed revision, not repeal (2026-10-24): passage-confirmation asks to express a close after a vision-verified abandonment (driver reversed out, boom left up because the operator's sensor was never tripped). Still never timed, never blind: only with a fresh verdict, an empty lane in the tracker, and after bench tests that the operator's loop/photocell override the command. Until those tests pass on park-lab the rule stands unchanged.